PT-2023-31551 · Primx · Primx Cryhod For Windows

Name of the Vulnerable Software and Affected Versions: PRIMX CRYHOD for Windows versions prior to Q.2020.4 PRIMX CRYHOD for Windows versions prior to 2023.5 Description: Encrypted disks created by PRIMX CRYHOD for Windows can be modified by an unauthenticated attacker to include a UNC reference,...

4.6CVSS4.8AI score0.00318EPSS
SaveExploits0References6
CVE
CVE
added 2023/12/13 12:0 a.m.38 views

CVE-2023-50442

The CVE-2023-50442 entry concerns PRIMX ZONECENTRAL (through version 2023.5) where a local attacker with sufficient privileges can modify encrypted folders to temporarily exclude specific file types from encryption. The underlying issue is a local-privilege scenario that enables altering encrypti...

5.5CVSS5.4AI score0.00127EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2023/12/13 12:0 a.m.33 views

CVE-2023-50441

CVE-2023-50441 affects PRIMX ZONECENTRAL for Windows: encrypted folders created before Q.2021.2 or before 2023.5 can be modified by an unauthenticated attacker to include a UNC reference, potentially triggering outbound network traffic when folders are opened. The entry indicates a low attack com...

5.5CVSS5.5AI score0.00241EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2023/12/13 12:0 a.m.43 views

CVE-2023-50444

CVE-2023-50444 affects PRIMX ZED! and related products where default containers include an encrypted version of sensitive user information. According to the sources, affected items include: ZED! for Windows before Q.2020.3; ZED! for Windows before Q.2021.2; ZONECENTRAL for Windows before Q.2021.2...

7.5CVSS7.5AI score0.00608EPSS
SaveExploits0References2Affected Software3
CNNVD
CNNVD
added 2023/12/13 12:0 a.m.7 views

PRIMX ZONECENTRAL Security Vulnerability

PRIMX ZONECENTRAL is an application from PRIMX USA. uses encryption to provide confidentiality services that apply to all documents of an organization. A security vulnerability exists in PRIMX ZONECENTRAL version 2023.5 and prior versions. An attacker could exploit the vulnerability to modify the...

5.5CVSS6.7AI score0.00127EPSS
SaveExploits0References3
Prion
Prion
added 2019/02/03 8:29 a.m.20 views

Code injection

Limited plaintext disclosure exists in PRIMX Zed Entreprise for Windows before 6.1.2240, Zed Entreprise for Windows ANSSI qualification submission before 6.1.2150, Zed Entreprise for Mac before 2.0.199, Zed Entreprise for Linux before 2.0.199, Zed Pro for Windows before 1.0.195, Zed Pro for Mac...

5CVSS5.2AI score0.01103EPSS
SaveExploits0References1Affected Software3
OSV
OSV
added 2019/02/03 8:29 a.m.7 views

CVE-2019-7312

Limited plaintext disclosure exists in PRIMX Zed Entreprise for Windows before 6.1.2240, Zed Entreprise for Windows ANSSI qualification submission before 6.1.2150, Zed Entreprise for Mac before 2.0.199, Zed Entreprise for Linux before 2.0.199, Zed Pro for Windows before 1.0.195, Zed Pro for Mac...

5.3CVSS6.1AI score0.01103EPSS
SaveExploits0References1
NVD
NVD
added 2019/02/03 8:29 a.m.23 views

CVE-2019-7312

Limited plaintext disclosure exists in PRIMX Zed Entreprise for Windows before 6.1.2240, Zed Entreprise for Windows ANSSI qualification submission before 6.1.2150, Zed Entreprise for Mac before 2.0.199, Zed Entreprise for Linux before 2.0.199, Zed Pro for Windows before 1.0.195, Zed Pro for Mac...

5.3CVSS5.2AI score0.01103EPSS
SaveExploits0References1
CVE
CVE
added 2019/02/03 8:0 a.m.65 views

CVE-2019-7312

CVE-2019-7312 describes a limited plaintext disclosure in PRIMX Zed Entreprise products (Windows, Mac, Linux) and related Zed Pro/Free lines, before the listed build numbers: Windows <6.1.2240 or ANSSI submission <6.1.2150; Mac/Linux <2.0.199; Pro/Free

5.3CVSS5.2AI score0.01103EPSS
SaveExploits0References1Affected Software3
Cvelist
Cvelist
added 2019/02/03 8:0 a.m.23 views

CVE-2019-7312

Limited plaintext disclosure exists in PRIMX Zed Entreprise for Windows before 6.1.2240, Zed Entreprise for Windows ANSSI qualification submission before 6.1.2150, Zed Entreprise for Mac before 2.0.199, Zed Entreprise for Linux before 2.0.199, Zed Pro for Windows before 1.0.195, Zed Pro for Mac...

5.2AI score0.01103EPSS
SaveExploits0References1
OSV
OSV
added 2018/11/14 8:29 p.m.5 views

CVE-2018-19279

PRIMX ZoneCentral before 6.1.2236 on Windows sometimes leaks the plaintext of NTFS files. On non-SSD devices, this is limited to a 5-second window and file sizes less than 600 bytes. The effect on SSD devices may be greater...

4.3CVSS5.8AI score0.00212EPSS
SaveExploits0References1
NVD
NVD
added 2018/11/14 8:29 p.m.12 views

CVE-2018-19279

PRIMX ZoneCentral before 6.1.2236 on Windows sometimes leaks the plaintext of NTFS files. On non-SSD devices, this is limited to a 5-second window and file sizes less than 600 bytes. The effect on SSD devices may be greater...

4.3CVSS4.7AI score0.00212EPSS
SaveExploits0References1
CVE
CVE
added 2018/11/14 8:0 p.m.35 views

CVE-2018-19279

PRIMX ZoneCentral prior to version 6.1.2236 on Windows has a vulnerability that can leak plaintext NTFS file contents. The leakage is time- and size-bounded: on non-SSD devices it is limited to a 5-second window and files smaller than 600 bytes; the impact on SSDs may be greater. The connected so...

4.3CVSS4.7AI score0.00212EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2018/11/14 8:0 p.m.21 views

CVE-2018-19279

PRIMX ZoneCentral before 6.1.2236 on Windows sometimes leaks the plaintext of NTFS files. On non-SSD devices, this is limited to a 5-second window and file sizes less than 600 bytes. The effect on SSD devices may be greater...