Lucene search
+L

9 matches found

NVD
NVD
•added 2026/06/19 1:16 p.m.•24 views

CVE-2026-56141

In JetBrains Hub before 2026.1.13757, 2025.3.148033, 2025.2.148048, 2025.1.148120, 2024.3.148430, 2024.2.148429 account takeover via predictable restore codes was possible...

9.8CVSS0.00522EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/10/30 12:00 a.m.•15 views

PT-2025-44430

Name of the Vulnerable Software and Affected Versions AG Life Logger versions prior to v1.0.2.72 Description The AG Life Logger Android App has issues with access control. Exposed credentials in network traffic could allow misuse of cloud resources. Predictable verification codes enable potential...

7.5CVSS6.7AI score0.00296EPSS
SaveExploits0References4
CVE
CVE
•added 2025/10/30 12:00 a.m.•44 views

CVE-2025-61120

The AG Life Logger Android App (package name com.donki.healthy), developed by IO FIT, K.K. , is vulnerable to improper access control in versions v1.0.2.72 and before . The root causes include exposed credentials in network traffic and predictable verification codes , which facilitate brute-force...

7.5CVSS5.8AI score0.00296EPSS
SaveExploits0References1
Prion
Prion
•added 2019/03/27 2:29 p.m.•26 views

Design/Logic Flaw

Due to the use of an insecure algorithm for rolling codes in the ABUS Secvest wireless alarm system FUAA50000 3.01.01 and its remote controls FUBE50014 and FUBE50015, an attacker is able to predict valid future rolling codes, and can thus remotely control the alarm system in an unauthorized way...

10CVSS9.3AI score0.02146EPSS
SaveExploits1References1Affected Software1
Prion
Prion
•added 2017/08/05 5:29 p.m.•24 views

Authentication flaw

DISPUTED An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the...

7.5CVSS7.3AI score0.01583EPSS
SaveExploits0References3
NVD
NVD
•added 2017/08/05 5:29 p.m.•29 views

CVE-2017-9855

An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer...

9.8CVSS9.6AI score0.01583EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2017/08/05 5:00 p.m.•45 views

CVE-2017-9855

An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer...

9.6AI score0.01583EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
•added 2017/08/05 5:00 p.m.•43 views

CVE-2017-9855

An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer...

7.2AI score0.01583EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2009/08/13 12:00 a.m.•6 views

CVE-2008-6971: Undefined Security Weakness

The password reset functionality in Simple Machines Forum SMF 1.0.x before 1.0.14, 1.1.x before 1.1.6, and 2.0 before 2.0 beta 4 includes clues about the random number generator state within a hidden form field and generates predictable validation codes, which allows remote attackers to modify...

7.5CVSS5.9AI score0.07131EPSS
SaveExploits3References2
Rows per page
Query Builder