1775 matches found
Manage Open Source Code Security Risks
Open source code is in the vast majority of commercial softwares today. Learn best practices to mitigate the unique risks that accompany its use...
Mitigate OT security threats with these best practices
The security community is continuously changing, growing, and learning from each other to better position the world against cyber threats. In the latest Voice of the Community blog series post, Microsoft Product Marketing Manager Natalia Godyla talks with Chris Sistrunk, Technical Manager in...
OPC Foundation UA Products Built with .NET Framework
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: OPC Foundation Equipment: OPC UA Servers Vulnerability: Uncontrolled Recursion 2. RISK EVALUATION Successful exploitation of this vulnerability could trigger a stack overflow. 3. TECHNICAL DETAILS 3.1...
Joint CISA-FBI Cybersecurity Advisory on DarkSide Ransomware
CISA and the Federal Bureau of Investigation FBI have released a Joint Cybersecurity Advisory CSA on a ransomware-as-a-service RaaS variant—referred to as DarkSide—recently used in a ransomware attack against a critical infrastructure CI company. Cybercriminal groups use DarkSide to gain access t...
Mitsubishi Electric GOT and Tension Controller (Update A)
1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: GOT and Tension Controller Vulnerability: Buffer Access with Incorrect Length Value 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-131-02...
Exploit for CVE-2020-14882
CVE-2020-14882 is a vulnerability in Oracle WebLogic Server. The vulnerability allows for unauthorized access and remote code execution. The vulnerability is caused by a flaw in the way the server handles certain types of requests, which can be exploited by an attacker to gain access to sensitive...
Advantech WISE-PaaS RMM
1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Advantech Equipment: WISE-PaaS/RMM Vulnerability: Use of Hard-coded Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to obtain sensitive information...
AMD RESPONSE TO “I see dead µops: leaking secrets via Intel/AMD micro-op caches” RESEARCH PAPER
Bulletin ID: AMD-SB-1006 Summary AMD has reviewed the research paper and believes existing mitigations were not being bypassed and no new mitigations are required. AMD recommends its existing side-channel mitigation guidance and standard secure coding practices be followed. CVE Details None...
Johnson Controls Exacq Technologies exacqVision
1. EXECUTIVE SUMMARY CVSS v3 7.0 Vendor: Exacq Technologies, Inc., a subsidiary of Johnson Controls, Inc. Equipment: exacqVision Vulnerability: Off-by-one Error 2. RISK EVALUATION A local attacker could exploit this vulnerability to obtain “Super User” access to the underlying Ubuntu Linux...
Cassia Networks Access Controller
1. EXECUTIVE SUMMARY CVSS v3 6.2 ATTENTION: Low attack complexity Vendor: Cassia Networks Equipment: Access Controller Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to read any file from the Access Controller server. 3...
DevSecOps: How to Systematize Security into the Dev Pipeline
Security within an organization cannot be siloed or left up for DevOps teams to figure out and manage. Learn how applying DevSecOps best practices will have a noticeable positive impact on the security of your overall applications...
Delta Industrial Automation COMMGR
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Delta Industrial Automation Equipment: COMMGR Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow for remote code execution or cause...
Delta Electronics CNCSoft-B
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: CNCSoft-B Vulnerabilities: Out-of-bounds Read, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead to arbitrary code execution. 3. TECHNICAL...
SUSE: Security Advisory (SUSE-SU-2019:2941-1)
The remote host is missing an update for the SPDX-FileCopyrightText: 2021 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
Schneider Electric SoMachine Basic
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: SoMachine Basic Vulnerability: Improper Restriction of XML External Entity Reference 2. RISK EVALUATION Successful exploitation of this vulnerability may result in...
FATEK Automation WinProladder
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: FATEK Automation Equipment: WinProladder Vulnerability: Integer Underflow 2. RISK EVALUATION Successful exploitation of this vulnerability could cause execution of arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS...
4 Steps to Container Lifecycle Security
Containers and Kubernetes have revolutionized developing, deploying, and scaling applications and infrastructure. Learn best practices for security across the container lifecycle, so you can guard your containers against attack...
New KrebsOnSecurity Mobile-Friendly Site
Dear Readers, this has been long overdue, but at last I give you a more responsive, mobile-friendly version of KrebsOnSecurity. We tried to keep the visual changes to a minimum and focus on a simple theme that presents information in a straightforward, easy-to-read format. Please bear with us ove...
CVE-2021-27450
SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E all firmware versions prior to v04A00.1...
Design/Logic Flaw