Lucene search
K

9 matches found

EUVD
EUVD
added 2026/05/03 6:30 a.m.5 views

EUVD-2026-26821

A weakness has been identified in Edimax BR-6428nC up to 1.16. This affects an unknown function of the file /goform/setWAN of the component Web Interface. This manipulation of the argument pppUserName/pptpUserName causes command injection. The attack can be initiated remotely. The exploit has bee...

6.5CVSS5.5AI score0.01521EPSS
Exploits0References6
CNNVD
CNNVD
added 2025/10/05 12:0 a.m.4 views

Belkin F9K1015 安全漏洞

Belkin F9K1015 is a WiFi signal extender from Belkin Canada. A security vulnerability exists in the Belkin F9K1015 version 1.00.10, which stems from incorrect manipulation of the parameter pptpUserName in the file /goform/formPPTPSetup, which could result in a buffer overflow...

9CVSS9AI score0.00206EPSS
Exploits1References5
EUVD
EUVD
added 2025/10/03 8:7 p.m.2 views

EUVD-2025-3041

Malicious code in bioql PyPI...

9.8CVSS6.6AI score0.00502EPSS
Exploits1References3
CNVD
CNVD
added 2025/07/11 12:0 a.m.2 views

Belkin F9K1122 Stack Buffer Overflow Vulnerability

The Belkin F9K1122 is a WiFi signal extender. The Belkin F9K1122 suffers from a stack buffer overflow vulnerability that stems from the parameter pptpUserName in the file /goform/formPPTPSetup failing to correctly validate the length size of the input data, no detailed vulnerability details are...

9CVSS7.3AI score0.01164EPSS
Exploits1References1
RedhatCVE
RedhatCVE
added 2025/05/23 11:37 a.m.4 views

CVE-2025-22904

RE11S v1.11 was discovered to contain a stack overflow via the pptpUserName parameter in the setWAN function...

9.8CVSS7.9AI score0.00502EPSS
Exploits1References1
NVD
NVD
added 2025/01/16 3:15 a.m.4 views

CVE-2025-22904

RE11S v1.11 was discovered to contain a stack overflow via the pptpUserName parameter in the setWAN function...

9.8CVSS0.00502EPSS
Exploits1References3
OSV
OSV
added 2025/01/16 3:15 a.m.1 views

CVE-2025-22904

RE11S v1.11 was discovered to contain a stack overflow via the pptpUserName parameter in the setWAN function...

9.8CVSS5.8AI score0.00502EPSS
Exploits1References3
CVE
CVE
added 2025/01/16 12:0 a.m.70 views

CVE-2025-22904

CVE-2025-22904 affects RE11S v1.11. A stack overflow has been discovered in the router’s setWAN function triggered by the pptpUserName parameter. Public documentation consistently identifies the affected component as RE11S v1.11 and describes the issue as a stack overflow with a potential impact ...

9.8CVSS7.5AI score0.00502EPSS
Exploits1References3Affected Software1
Vulnrichment
Vulnrichment
added 2025/01/16 12:0 a.m.7 views

CVE-2025-22904

RE11S v1.11 was discovered to contain a stack overflow via the pptpUserName parameter in the setWAN function...

8.1AI score0.00502EPSS
Exploits1References3
Rows per page
Query Builder