534 matches found
CVE-2025-11387
A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fastsettingpppoeset. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may ...
CVE-2025-11387 Tenda AC15 fast_setting_pppoe_set stack-based overflow
A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fastsettingpppoeset. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may ...
CVE-2025-11387
CVE-2025-11387 affects Tenda AC15 routers (AO: 15.03.05.18) via the function in /goform/fast_setting_pppoe_set. The vulnerability is a stack-based buffer overflow caused by manipulated Password input, and is exploitable remotely with a publicly disclosed exploit (PoC). Multiple sources corroborat...
EUVD-2004-1387
Malware in sbrugna...
EUVD-2021-20865
Malware in sbrugna...
EUVD-2014-3297
Malware in sbrugna...
EUVD-2004-1388
Malware in sbrugna...
EUVD-2011-0474
Malware in sbrugna...
EUVD-2009-4874
Malware in sbrugna...
EUVD-2016-8778
Malware in sbrugna...
EUVD-2017-17050
Malware in sbrugna...
EUVD-2004-0563
Malware in sbrugna...
EUVD-2007-2518
Malware in sbrugna...
EUVD-2012-1276
Malware in sbrugna...
EUVD-2014-6266
Malware in sbrugna...
EUVD-2008-3570
Malware in sbrugna...
PT-2025-40978
Name of the Vulnerable Software and Affected Versions Tenda AC15 version 15.03.05.18 Description A stack-based buffer overflow exists in Tenda AC15 routers. The issue is due to the manipulation of the Password argument within the file '/goform/fast setting pppoe set'. This can be exploited...
CVE-2025-11325
A security flaw has been discovered in Tenda AC18 15.03.05.196318. Affected by this issue is some unknown functionality of the file /goform/fastsettingpppoeset. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out...
EUVD-2025-32509
A security flaw has been discovered in Tenda AC18 15.03.05.196318. Affected by this issue is some unknown functionality of the file /goform/fastsettingpppoeset. Performing manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out...
CVE-2025-11325
CVE-2025-11325 affects Tenda AC18 routers (firmware around 15.03.05.19(6318)). The vulnerability is a stack-based overflow in the /goform/fast_setting_pppoe_set handler triggered by manipulating the Username parameter. It is remotely exploitable, with public exploit code available. Impact include...