Lucene search
K

10 matches found

NVD
NVD
added 6 days ago11 views

CVE-2026-10125

A vulnerability was identified in Edimax BR-6478AC 1.23. Affected by this vulnerability is the function formPPPoESetup of the file /goform/formPPPoESetup of the component POST Request Handler. The manipulation of the argument pppUserName leads to stack-based buffer overflow. The attack can be...

9CVSS0.00041EPSS
Exploits0References4
CVE
CVE
added 6 days ago10 views

CVE-2026-10125

CVE-2026-10125 affects Edimax BR-6478AC firmware 1.23. The issue is in the POST Request Handler’s file /goform/formPPPoESetup, specifically the formPPPoESetup function. Manipulating the pppUserName argument triggers a stack-based buffer overflow, with remote initiation possible. Public exploit ma...

9CVSS8AI score0.00041EPSS
Exploits0References4
ATTACKERKB
ATTACKERKB
added 6 days ago5 views

CVE-2026-10125

A vulnerability was identified in Edimax BR-6478AC 1.23. Affected by this vulnerability is the function formPPPoESetup of the file /goform/formPPPoESetup of the component POST Request Handler. The manipulation of the argument pppUserName leads to stack-based buffer overflow. The attack can be...

9CVSS8AI score0.00041EPSS
Exploits0References4Affected Software1
EUVD
EUVD
added 6 days ago14 views

EUVD-2026-33468

A vulnerability was identified in Edimax BR-6478AC 1.23. Affected by this vulnerability is the function formPPPoESetup of the file /goform/formPPPoESetup of the component POST Request Handler. The manipulation of the argument pppUserName leads to stack-based buffer overflow. The attack can be...

9CVSS6.4AI score0.00041EPSS
Exploits0References4
CVE
CVE
added 2026/05/24 12:30 p.m.11 views

CVE-2026-9381

The CVE describes a buffer overflow in Edimax BR-6675nD firmware version 1.12 affecting the POST Request Handler’s formPPPoESetup function (file /goform/formPPPoESetup). The issue is triggered by manipulating the pppUserName argument, potentially allowing remote exploitation. Public exploit infor...

9CVSS7.8AI score0.00046EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/03 8:7 p.m.3 views

EUVD-2025-23926

Malicious code in bioql PyPI...

9.4CVSS6.6AI score0.01714EPSS
Exploits0References2
NVD
NVD
added 2025/08/07 5:15 p.m.3 views

CVE-2025-34151

A command injection vulnerability exists in the 'passwd' parameter of the PPPoE setup process on the Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02. The input is passed directly to system-level commands without sanitation, enabling unauthenticated attackers to achieve root-level code...

9.4CVSS0.01714EPSS
Exploits0References3
Vulnrichment
Vulnrichment
added 2025/08/07 4:45 p.m.3 views

CVE-2025-34151 Shenzhen Aitemi M300 Wi-Fi Repeater PPPoE Password Command Injection

A command injection vulnerability exists in the 'passwd' parameter of the PPPoE setup process on the Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02. The input is passed directly to system-level commands without sanitation, enabling unauthenticated attackers to achieve root-level code...

9.4CVSS7.6AI score0.01714EPSS
Exploits0References3
OSV
OSV
added 2025/07/06 6:15 p.m.1 views

CVE-2025-7088

A vulnerability, which was classified as critical, was found in Belkin F9K1122 1.00.33. This affects the function formPPPoESetup of the file /goform/formPPPoESetup of the component webs. The manipulation of the argument pppUserName leads to stack-based buffer overflow. It is possible to initiate...

8.7CVSS6.3AI score
Exploits0References5
Positive Technologies
Positive Technologies
added 2025/01/16 12:0 a.m.2 views

PT-2025-4745 · Re11S · Re11S

Name of the Vulnerable Software and Affected Versions: RE11S version 1.11 Description: A stack overflow issue was discovered in the formPPPoESetup function via the pppUserName parameter. This issue affects the PPPoE setup functionality. Recommendations: For RE11S version 1.11, as a temporary...

10CVSS6.6AI score0.00384EPSS
Exploits1References10
Rows per page
Query Builder