228 matches found
The vulnerability of the microprogramming software of the Schneider Electric PowerLogic P7 relay protection device, related to the failure to take measures to neutralize special elements, allows a intruder to execute arbitrary commands.
The vulnerability of the microprogramming software of Schneider Electric PowerLogic P7 relay protection devices relates to the lack of measures to neutralize special elements. Exploiting this vulnerability could allow a remote attacker to execute arbitrary commands...
The vulnerability of the microprogramming software of Schneider Electric PowerLogic P7 relay protection devices, related to pointer assignment errors, allows a intruder to trigger a service failure.
The vulnerability of the microprogramming software of Schneider Electric PowerLogic P7 relay protection devices relates to pointer assignment errors. Exploiting this vulnerability could allow an attacker to trigger a service failure...
The vulnerability of the microprogramming software of Schneider Electric PowerLogic P7 relay protection devices, related to the underutilization of the assert() function, allows a intruder to trigger a malfunction during maintenance.
The vulnerability of the microprogramming software of the Schneider Electric PowerLogic P7 relay protection device for electrical systems is related to the lack of use of the “assert” function. Exploiting this vulnerability could allow a malicious actor to trigger a service failure...
CVE-2021-22703
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 see notification for affected versions, that could cause disclosure of user credentials when a malicious actor intercepts HTT...
CVE-2021-22767
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 Versions 3.0.0 and newer and PowerLogic EGX300 All Versions that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276...
CVE-2021-22714
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 All versions prior to V3.0.0, which could cause the meter to reboot or allow for remote code execution...
CVE-2021-22763
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could allow an attacker administrator level access to a device...
CVE-2021-22701
A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 see notification for affected versions, that could cause a user to perform an unintended action on the target device when using the HTTP web...
CVE-2021-22768
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 Versions 3.0.0 and newer and PowerLogic EGX300 All Versions that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767...
CVE-2021-22764
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...
CVE-2021-22702
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 see notification for affected versions, that could cause disclosure of user credentials when a malicious actor...
CVE-2021-22766
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 Versions 3.0.0 and newer and PowerLogic EGX300 All Versions that could cause denial of service via a specially crafted HTTP packet...
CVE-2021-22713
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 see security notifcation for affected versions, which could cause the meter to reboot...
EUVD-2016-5500
Malware in sbrugna...
EUVD-2018-19507
Malware in sbrugna...
EUVD-2013-2735
Malware in sbrugna...
EUVD-2016-6753
Malware in sbrugna...
EUVD-2021-9837
Malicious code in bioql PyPI...