19 matches found
EUVD-2024-15962
Malicious code in bioql PyPI...
CVE-2025-26482: Exposure of Sensitive System Information Due to Uncleared Debug Information
Dell PowerEdge Server BIOS and Dell iDRAC9, all versions, contains an Information Disclosure vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information Disclosure...
CVE-2024-0171: Time-of-check Time-of-use (TOCTOU) Race Condition
Dell PowerEdge Server BIOS contains an TOCTOU race condition vulnerability. A local low privileged attacker could potentially exploit this vulnerability to gain access to otherwise unauthorized resources...
PT-2024-15365
Name of the Vulnerable Software and Affected Versions Dell PowerEdge Server BIOS affected versions not specified Description The issue is related to a TOCTOU race condition vulnerability. A local low privileged attacker could potentially exploit this vulnerability to gain access to otherwise...
Dell PowerEdge Server BIOS 和 Dell Precision Rack BIOS 安全漏洞
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS are both products of Dell USA.Dell PowerEdge Server BIOS is a system update driver from Dell.Dell Precision Rack BIOS is the Dell Precision Rack BIOS is a BIOS utility for high performance workstation products. A security vulnerability exist...
CVE-2024-0172: Improper Privilege Management
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation...
CVE-2024-25942: Improper Input Validation
Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM...
CVE-2024-22453: Heap-based Buffer Overflow
Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory...
CVE-2024-0162: Improper Restriction of Operations within the Bounds of a Memory Buffer
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to out-of-bound read/writes to SMRAM...
CVE-2024-0161: Improper Input Validation
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM...
CVE-2024-0163: Time-of-check Time-of-use (TOCTOU) Race Condition
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain a TOCTOU race condition vulnerability. A local low privileged attacker could potentially exploit this vulnerability to gain access to otherwise unauthorized resources...
CVE-2024-0173: Access of Memory Location After End of Buffer
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory...
CVE-2024-0154: Access of Memory Location After End of Buffer
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory...
Dell PowerEdge Server BIOS 访问控制错误漏洞
Dell PowerEdge Server BIOS is a system update driver for the Dell Dell of the United States. The Dell PowerEdge Server BIOS has an authorization issue vulnerability that stems from the inclusion of incorrect privilege management, which can be exploited by an unauthenticated, local attacker to cau...
Dell PowerEdge Server BIOS 缓冲区错误漏洞
Dell PowerEdge Server BIOS is a system update driver for the Dell Dell from Dell Dell USA. A security vulnerability exists in the Dell PowerEdge Server BIOS that stems from an incorrect SMM communications buffer validation vulnerability...
CVE-2022-22558: Improper Restriction of Operations within the Bounds of a Memory Buffer
Dell PowerEdge Server BIOS and Dell Precision Workstation 7910 and 7920 Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A Local High Privileged attacker could potentially exploit this vulnerability leading to arbitrary writes or denial of service...
PT-2021-14605 · Dell · Dell Precision Rack Bios +1
Name of the Vulnerable Software and Affected Versions: Dell PowerEdge Server BIOS affected versions not specified Dell Precision Rack BIOS affected versions not specified Description: The issue is related to an out-of-bounds array access. A local malicious user with high privileges may exploit...
CVE-2021-21557: Improper Input Validation
Dell PowerEdge Server BIOS and select Dell Precision Rack BIOS contain an out-of-bounds array access vulnerability. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of service, arbitrary code execution, or information disclosure in System...
PT-2021-14604
Name of the Vulnerable Software and Affected Versions Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS affected versions not specified Description A stack-based buffer overflow vulnerability exists in systems with NVDIMM-N installed, which can be exploit...