Lucene search
+L

14019 matches found

Prion
Prion
•added 2022/01/28 8:15 p.m.•38 views

Cross site scripting

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply UP...

4.3CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software2
Prion
Prion
•added 2022/01/28 8:15 p.m.•32 views

Input validation

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure? Power Monitoring Expert 9.0 and prior versions...

6.8CVSS8.9AI score0.01201EPSS
SaveExploits0References1Affected Software1
Prion
Prion
•added 2022/01/28 8:15 p.m.•36 views

Cross site scripting

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power...

4.3CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software2
Prion
Prion
•added 2022/01/28 8:15 p.m.•39 views

Cross site scripting

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

4.3CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software2
CVE
CVE
•added 2022/01/28 7:09 p.m.•101 views

CVE-2021-22815

The CVE-2021-22815 entry covers an Information Exposure vulnerability in Schneider Electric NMC/NMC2/NMC3 embedded devices and related APC equipment. Affected products include 1-phase and 3-phase UPS with NMC2/NMC3 (AP9630/9631/9635 on NMC2; AP9640/9641/9643 on NMC3), NMC2/NMC3-based PDUs, XRDP/X...

5.3CVSS5.2AI score0.00768EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2022/01/28 7:09 p.m.•49 views

CVE-2021-22814

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

6.5AI score0.00745EPSS
SaveExploits0References1
CVE
CVE
•added 2022/01/28 7:09 p.m.•81 views

CVE-2021-22814

CVE-2021-22814 describes a Cross-site Scripting (CWE-79) vulnerability in Schneider Electric NMC embedded devices (NMC2 and NMC3) that can cause arbitrary script execution when a malicious file is read and displayed. Affected products span multiple Schneider Electric lines: 1-phase and 3-phase UP...

6.1CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2022/01/28 7:09 p.m.•62 views

CVE-2021-22813

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products:...

6.4AI score0.00745EPSS
SaveExploits0References1
CVE
CVE
•added 2022/01/28 7:09 p.m.•95 views

CVE-2021-22813

CVE-2021-22813 is a Cross‑Site Scripting (CWE-79) vulnerability affecting Schneider Electric NMC/NMC2/NMC3 devices across UPS, PDU, and related network cards. A privileged user can trigger arbitrary script execution by clicking a malicious URL referencing an edit policy file. The connected docume...

6.1CVSS6.1AI score0.00745EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2022/01/28 7:09 p.m.•49 views

CVE-2021-22812

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power...

6.5AI score0.00745EPSS
SaveExploits0References1
CVE
CVE
•added 2022/01/28 7:09 p.m.•96 views

CVE-2021-22812

CVE-2021-22812 is a Cross-Site Scripting (CWE-79) vulnerability affecting Schneider Electric NMC/NMC2/NMC3 embedded devices and related UPS, PDU, and cooling products. Affected items include NMC2/NMC3 applications across various AP9630/9631/9635/9640/9641/9643 series and related RPDU2G, RPP, XRDP...

6.1CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2022/01/28 7:09 p.m.•79 views

CVE-2021-22811

CVE-2021-22811 is a cross-site scripting vulnerability in Schneider Electric NMC/NMC2/NMC3 web interfaces. The issue could permit arbitrary script execution when a privileged user accesses a vulnerable web page or when a malicious URL crafted for the NMC is used. Affected products span multiple S...

6.1CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2022/01/28 7:09 p.m.•45 views

CVE-2021-22811

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply UP...

6.5AI score0.00745EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2022/01/28 7:09 p.m.•61 views

CVE-2021-22810

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products:...

6.4AI score0.00749EPSS
SaveExploits0References1
CVE
CVE
•added 2022/01/28 7:09 p.m.•87 views

CVE-2021-22827

CVE-2021-22827 corresponds to an improper input validation (CWE-20) vulnerability in EcoStruxure Power Monitoring Expert 9.0 and earlier. Red Hat entries corroborate that this flaw could lead to arbitrary code execution when a user visits a page containing the injected payload; this CVE is distin...

8.8CVSS8.8AI score0.01201EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2022/01/28 7:09 p.m.•119 views

CVE-2021-22826

The connected Red Hat entries confirm CVE-2021-22826 is an input-validation flaw (CWE-20) in EcoStruxure Power Monitoring Expert 9.0 and earlier. The vulnerability allows arbitrary code execution when a user visits a page containing the injected payload. The issue is tied to CVE-2021-22827 as a s...

8.8CVSS8.8AI score0.01201EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/01/28 12:00 a.m.•12 views

CVE-2021-22814: Improper Neutralization of Input During Web Page Generation

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

6.1CVSS6.4AI score0.00745EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/01/28 12:00 a.m.•2 views

CVE-2021-22826: Improper Input Validation

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions...

8.8CVSS8.1AI score0.01201EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2022/01/28 12:00 a.m.•21 views

Schneider Electric EcoStruxure Power Monitoring Expert has a vulnerability in input validation.

Schneider Electric EcoStruxure Power Monitoring Expert is a device from Schneider Electric France for power distribution monitoring in IoT environments. An input validation error vulnerability exists in Schneider Electric EcoStruxure Power Monitoring Expert version 9.0 and prior versions, which...

8.8CVSS8.3AI score0.01201EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2022/01/28 12:00 a.m.•24 views

Schneider Electric EcoStruxure Power Monitoring Expert has a vulnerability in input validation.

Schneider Electric EcoStruxure Power Monitoring Expert is a device from Schneider Electric France for power distribution monitoring in IoT environments. An input validation error vulnerability exists in Schneider Electric EcoStruxure Power Monitoring Expert version 9.0 and prior versions, which...

8.8CVSS8.3AI score0.01201EPSS
SaveExploits0References2
Rows per page
Query Builder