PT-2022-3485 · Schneider Electric · Ecostruxure Power Commission
Name of the Vulnerable Software and Affected Versions: EcoStruxure Power Commission versions prior to V2.22 Description: The issue is related to an improper limitation of a pathname to a restricted directory, also known as a 'Path Traversal' vulnerability. This could allow a remote attacker to...
CVE-2022-26476: Use of Hard-coded Credentials
A vulnerability has been identified in Spectrum Power 4 All versions using Shared HIS, Spectrum Power 7 All versions using Shared HIS, Spectrum Power MGMS All versions using Shared HIS. An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an...
PT-2022-3480 · Schneider Electric · Ecostruxure Power Commission
Name of the Vulnerable Software and Affected Versions: EcoStruxure Power Commission versions prior to V2.22 Description: The issue is related to an improper limitation of a pathname to a restricted directory, also known as a 'Path Traversal' vulnerability. This could allow a remote attacker to...
Software Developer Guidance for Power Advisory
Summary: A potential security vulnerability in some Intel® Processors may allow information disclosure. Intel is releasing guidance to address this potential vulnerability. Vulnerability Details: CVEID: CVE-2022-24436 Description: Observable behavioral in power management throttling for some Inte...
PT-2022-3521 · Schneider Electric · Ecostruxure Power Commission
Name of the Vulnerable Software and Affected Versions: EcoStruxure Power Commission versions prior to V2.22 Description: A vulnerability exists that could cause all remote domains to access the resources supplied by the server when an attacker sends a fetch request from a third-party site or...
CVE-2022-33174
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...
CVE-2022-33175
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/getparam.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrator...
CVE-2022-33174
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...
CVE-2022-33175
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/getparam.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrator...
CVE-2022-33175
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/getparam.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrator...
CVE-2022-33174
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...
Authorization
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...
CVE-2022-33174
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...
CVE-2022-33174
Summary: CVE-2022-33174 affects Powertek firmware-based Power Distribution Units prior to 3.30.30. An attacker can bypass active session authorization by sending an HTTP request to /cgi/get_param.cgi with the tmpToken cookie set to an empty string followed by a semicolon, enabling access to prote...
CVE-2022-33175
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/getparam.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrator...
CVE-2022-33175
Power Distribution Units (Powertek firmware) prior to 3.30.30 are affected. The vulnerability arises from an insecure permissions setting on the user.token field, exposed via the /cgi/get_param.cgi HTTP API, allowing disclosure of active administrator session IDs. This can enable session hijackin...
Bluetooth Signals Can Be Used to Track Smartphones, Say Researchers
Researchers warn Bluetooth signals can be used to track device owners via a unique fingerprinting of the radio signal. The technique was presented via a paper presented at IEEE Security and Privacy conference last month by researchers at the University of California San Diego. The paper suggests...
Powertek PDU security vulnerability
Powertek, a company that manufactures data center-grade intelligent PDUs power distribution units, or heavy-duty power cords for server racks, has an authentication bypass vulnerability that can be exploited by an attacker to bypass active session authorization checks. It can then be used to gain...
Powertek PDU security vulnerability
Powertek is a company that manufactures data center-grade intelligent PDUs Power Distribution Units, i.e., heavy-duty power strips for server racks. The Powertek PDUs suffer from a buffer overflow vulnerability that can be exploited by an attacker to cause disclosure of the active session id of t...
CVE-2022-33175: Incorrect Permission Assignment for Critical Resource
Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/getparam.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrator...