14007 matches found
PT-2023-3769 · Siemens · Sicam Q200 +1
Name of the Vulnerable Software and Affected Versions: POWER METER SICAM Q100 versions prior to V2.60 Siemens SICAM Q200 affected versions not specified Description: A vulnerability has been identified where affected devices are missing cookie protection flags when using the default settings. Thi...
PT-2023-3131 · Microsoft · Power Apps
Name of the Vulnerable Software and Affected Versions: Microsoft Power Apps affected versions not specified Description: The issue is related to errors in the representation of information by the user interface in the Microsoft Power Apps development environment. Exploitation of this issue may...
Microsoft Power Apps security vulnerabilities
Microsoft Power Apps is a low-code development platform from Microsoft Corporation USA designed to help users easily build customized enterprise-class applications. A security vulnerability exists in Microsoft Power Apps that stems from the presence of a spoofing vulnerability...
Siemens POWER METER SICAM Cross-site Request Forgery Vulnerability
The SICAM Q200 is a multifunctional device for detecting, reporting and analyzing measured values and events. A cross-site request forgery vulnerability exists in the Siemens SICAM Q200, which can be exploited by an attacker to perform arbitrary actions on the device on behalf of a vulnerable use...
KLA50320 Multiple vulnerabilities in Microsoft Dynamics
Multiple vulnerabilities were found in Microsoft Dynamics. Malicious users can exploit these vulnerabilities to spoof user interface. Below is a complete list of vulnerabilities: 1. A spoofing vulnerability in Microsoft Power Apps can be exploited remotely to spoof user interface. 2. A spoofing...
PT-2023-3377
Name of the Vulnerable Software and Affected Versions POWER METER SICAM Q100 versions prior to V2.60 POWER METER SICAM Q200 affected versions not specified Description A vulnerability has been identified in the web interface of the affected devices, making them vulnerable to Cross-Site Request...
Fuji Electric Tellus Lite V-Simulator Buffer Overflow
The vulnerability of the monitoring software for PLCCs from Fuji Electric, Tellus Lite V-Simulator, is related to buffer overflow in the stack. Exploiting this vulnerability can allow an attacker to execute arbitrary code...
CVE-2023-1898
Atlas Copco Power Focus 6000 web server uses a small amount of session ID numbers. An attacker could enter a session ID number to retrieve data for an active user’s session...
CVE-2023-1897
Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller...
CVE-2023-1899
Atlas Copco Power Focus 6000 web server is not a secure connection by default, which could allow an attacker to gain sensitive information by monitoring network traffic between user and controller...
Code injection
Atlas Copco Power Focus 6000 web server is not a secure connection by default, which could allow an attacker to gain sensitive information by monitoring network traffic between user and controller...
Design/Logic Flaw
Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller...
Session fixation
Atlas Copco Power Focus 6000 web server uses a small amount of session ID numbers. An attacker could enter a session ID number to retrieve data for an active user’s session...
CVE-2023-1897
Atlas Copco Power Focus 6000 web server is affected by CVE-2023-1897: it does not sanitize login information stored by the authenticated user’s browser, allowing a user‑with‑access‑to‑their‑computer attacker to obtain credentials for the controller. Affected product: Power Focus 6000 web server (...
CVE-2023-1897 CVE-2023-1897
Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller...
CVE-2023-1897 CVE-2023-1897
Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller...
CVE-2023-1898
CVE-2023-1898 affects Atlas Copco Power Focus 6000 web server. The issue is a small space of session IDs that could allow an attacker to enter a valid session ID and retrieve data for an active user’s session. Reported as a high-severity, remotely exploitable condition with low attack complexity ...
CVE-2023-1898 CVE-2023-1898
Atlas Copco Power Focus 6000 web server uses a small amount of session ID numbers. An attacker could enter a session ID number to retrieve data for an active user’s session...
CVE-2023-1899
Atlas Copco Power Focus 6000 web server is affected by CVE-2023-1899 (cleartext transmission of sensitive information). Public documents confirm that the Power Focus 6000 web interface does not use a secure connection by default, enabling potential interception of credentials or sensitive data ov...
CVE-2023-1899 CVE-2023-1899
Atlas Copco Power Focus 6000 web server is not a secure connection by default, which could allow an attacker to gain sensitive information by monitoring network traffic between user and controller...