PT-2023-3769 · Siemens · Sicam Q200 +1

Name of the Vulnerable Software and Affected Versions: POWER METER SICAM Q100 versions prior to V2.60 Siemens SICAM Q200 affected versions not specified Description: A vulnerability has been identified where affected devices are missing cookie protection flags when using the default settings. Thi...

5.5CVSS5AI score0.00427EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2023/06/13 12:00 a.m.•26 views

PT-2023-3131 · Microsoft · Power Apps

Name of the Vulnerable Software and Affected Versions: Microsoft Power Apps affected versions not specified Description: The issue is related to errors in the representation of information by the user interface in the Microsoft Power Apps development environment. Exploitation of this issue may...

3CVSS9.2AI score0.01488EPSS
SaveExploits0References6
CNNVD
CNNVD
•added 2023/06/13 12:00 a.m.•23 views

Microsoft Power Apps security vulnerabilities

Microsoft Power Apps is a low-code development platform from Microsoft Corporation USA designed to help users easily build customized enterprise-class applications. A security vulnerability exists in Microsoft Power Apps that stems from the presence of a spoofing vulnerability...

3CVSS6.3AI score0.01488EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2023/06/13 12:00 a.m.•25 views

Siemens POWER METER SICAM Cross-site Request Forgery Vulnerability

The SICAM Q200 is a multifunctional device for detecting, reporting and analyzing measured values and events. A cross-site request forgery vulnerability exists in the Siemens SICAM Q200, which can be exploited by an attacker to perform arbitrary actions on the device on behalf of a vulnerable use...

8.8CVSS6.9AI score0.00361EPSS
SaveExploits0References8
Kaspersky
Kaspersky
•added 2023/06/13 12:00 a.m.•45 views

KLA50320 Multiple vulnerabilities in Microsoft Dynamics

Multiple vulnerabilities were found in Microsoft Dynamics. Malicious users can exploit these vulnerabilities to spoof user interface. Below is a complete list of vulnerabilities: 1. A spoofing vulnerability in Microsoft Power Apps can be exploited remotely to spoof user interface. 2. A spoofing...

5.4CVSS5.4AI score0.01488EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2023/06/13 12:00 a.m.•11 views

PT-2023-3377

Name of the Vulnerable Software and Affected Versions POWER METER SICAM Q100 versions prior to V2.60 POWER METER SICAM Q200 affected versions not specified Description A vulnerability has been identified in the web interface of the affected devices, making them vulnerable to Cross-Site Request...

8.8CVSS8.7AI score0.00361EPSS
SaveExploits0References12
BDU FSTEC
BDU FSTEC
•added 2023/06/13 12:00 a.m.•22 views

Fuji Electric Tellus Lite V-Simulator Buffer Overflow

The vulnerability of the monitoring software for PLCCs from Fuji Electric, Tellus Lite V-Simulator, is related to buffer overflow in the stack. Exploiting this vulnerability can allow an attacker to execute arbitrary code...

7.8CVSS7.9AI score0.0026EPSS
SaveExploits0References5Affected Software1
NVD
NVD
•added 2023/06/12 8:15 p.m.•34 views

CVE-2023-1898

Atlas Copco Power Focus 6000 web server uses a small amount of session ID numbers. An attacker could enter a session ID number to retrieve data for an active user’s session...

9.4CVSS9.3AI score0.00559EPSS
SaveExploits0References1
NVD
NVD
•added 2023/06/12 8:15 p.m.•32 views

CVE-2023-1897

Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller...

9.4CVSS9.2AI score0.00341EPSS
SaveExploits0References1
NVD
NVD
•added 2023/06/12 8:15 p.m.•34 views

CVE-2023-1899

Atlas Copco Power Focus 6000 web server is not a secure connection by default, which could allow an attacker to gain sensitive information by monitoring network traffic between user and controller...

9.4CVSS9.3AI score0.00341EPSS
SaveExploits0References1
Prion
Prion
•added 2023/06/12 8:15 p.m.•24 views

Code injection

Atlas Copco Power Focus 6000 web server is not a secure connection by default, which could allow an attacker to gain sensitive information by monitoring network traffic between user and controller...

5CVSS7.5AI score0.00341EPSS
SaveExploits0References1
Prion
Prion
•added 2023/06/12 8:15 p.m.•30 views

Design/Logic Flaw

Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller...

5CVSS7.4AI score0.00341EPSS
SaveExploits0References1
Prion
Prion
•added 2023/06/12 8:15 p.m.•30 views

Session fixation

Atlas Copco Power Focus 6000 web server uses a small amount of session ID numbers. An attacker could enter a session ID number to retrieve data for an active user’s session...

5CVSS7.4AI score0.00559EPSS
SaveExploits0References1
CVE
CVE
•added 2023/06/12 7:18 p.m.•79 views

CVE-2023-1897

Atlas Copco Power Focus 6000 web server is affected by CVE-2023-1897: it does not sanitize login information stored by the authenticated user’s browser, allowing a user‑with‑access‑to‑their‑computer attacker to obtain credentials for the controller. Affected product: Power Focus 6000 web server (...

9.4CVSS7.8AI score0.00341EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2023/06/12 7:18 p.m.•43 views

CVE-2023-1897 CVE-2023-1897

Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller...

9.4CVSS9.3AI score0.00341EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2023/06/12 7:18 p.m.•16 views

CVE-2023-1897 CVE-2023-1897

Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller...

9.4CVSS9.2AI score0.00341EPSS
SaveExploits0References1
CVE
CVE
•added 2023/06/12 7:16 p.m.•68 views

CVE-2023-1898

CVE-2023-1898 affects Atlas Copco Power Focus 6000 web server. The issue is a small space of session IDs that could allow an attacker to enter a valid session ID and retrieve data for an active user’s session. Reported as a high-severity, remotely exploitable condition with low attack complexity ...

9.4CVSS7.8AI score0.00559EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2023/06/12 7:16 p.m.•51 views

CVE-2023-1898 CVE-2023-1898

Atlas Copco Power Focus 6000 web server uses a small amount of session ID numbers. An attacker could enter a session ID number to retrieve data for an active user’s session...

9.4CVSS9.4AI score0.00559EPSS
SaveExploits0References1
CVE
CVE
•added 2023/06/12 7:13 p.m.•77 views

CVE-2023-1899

Atlas Copco Power Focus 6000 web server is affected by CVE-2023-1899 (cleartext transmission of sensitive information). Public documents confirm that the Power Focus 6000 web interface does not use a secure connection by default, enabling potential interception of credentials or sensitive data ov...

9.4CVSS7.9AI score0.00341EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2023/06/12 7:13 p.m.•12 views

CVE-2023-1899 CVE-2023-1899

Atlas Copco Power Focus 6000 web server is not a secure connection by default, which could allow an attacker to gain sensitive information by monitoring network traffic between user and controller...

9.4CVSS6.7AI score0.00341EPSS
SaveExploits0References1