38 matches found
CVE-2025-30037: Missing Authentication for Critical Function
The system exposes several endpoints, typically including "/int/" in their path, that should be restricted to internal services, but are instead publicly accessible without authentication to any host able to reach the application server on port 443/tcp...
Siemens SICAM Q100 Improper Input Validation (CVE-2022-43545)
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...
Siemens SICAM Q100 Improper Input Validation (CVE-2022-43439)
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...
Command injection
A vulnerability has been identified in CP-8031 MASTER MODULE All versions CPCI85 V05, CP-8050 MASTER MODULE All versions CPCI85 V05. Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operation” is enabled. The parameter is disabled by...
CVE-2023-28489
A vulnerability has been identified in CP-8031 MASTER MODULE All versions CPCI85 V05, CP-8050 MASTER MODULE All versions CPCI85 V05. Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operation” is enabled. The parameter is disabled by...
CVE-2023-28489: Improper Neutralization of Special Elements used in a Command
A vulnerability has been identified in CP-8031 MASTER MODULE All versions CPCI85 V05, CP-8050 MASTER MODULE All versions CPCI85 V05. Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operation” is enabled. The parameter is disabled by...
Siemens SCALANCE M875 Cross-site Scripting (CVE-2018-11448)
A vulnerability has been identified in SCALANCE M875 All versions. The web interface on port 443/tcp could allow a stored Cross-Site Scripting XSS attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web...
Siemens SCALANCE S-600 Uncontrolled Resource Consumption (CVE-2019-13926)
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold r...
CVE-2022-43546
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...
Siemens SIPROTEC 5 and DIGSI 5 Improper Input Validation (CVE-2019-10930)
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules All versions , DIGSI 5 engineering software All versions V7.90, SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87,...
Siemens SICAM A8000 RTU Series Uncaught Exception (CVE-2018-13798)
A vulnerability has been identified in SICAM A8000 CP-8000 All versions V14, SICAM A8000 CP-802X All versions V14, SICAM A8000 CP-8050 All versions V2.00. Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service...
VMware vCenter Server Path Traversal Vulnerability
Vmware VMware vCenter Server is a suite of server and virtualization management software from Vmware, Inc. The software provides a centralized platform for managing VMware vSphere environments, automating the implementation and delivery of virtual infrastructure. vCenter Server is vulnerable to a...
CVE-2020-28330: Insufficiently Protected Credentials
Barco wePresent WiPG-1600W devices have Unprotected Transport of Credentials. Affected Versions: 2.5.1.8. An attacker armed with hardcoded API credentials retrieved by exploiting CVE-2020-28329 can issue an authenticated query to display the admin password for the main web user interface listenin...
CVE-2019-13925
CVE-2019-13925 affects Siemens SCALANCE S-600 family (S602, S612, S623, S627-2M) v3.0–v4.0.x, where specially crafted packets to port 443/tcp can cause an unbounded/ uncontrolled resource consumption and DoS on the web server. Root cause is an Uncontrolled Resource Consumption issue in the integr...
CVE-2019-13926
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionalit...
CVE-2019-13925: Uncontrolled Resource Consumption
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server...
CVE-2019-13926: Uncontrolled Resource Consumption
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionalit...
CVE-2019-13940: Uncontrolled Resource Consumption
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU All versions V3.X.17, SIMATIC ET 200pro IM154-8F PN/DP CPU All versions V3.X.17, SIMATIC ET 200pro IM154-8FX PN/DP CPU All versions V3.X.17, SIMATIC ET 200S IM151-8 PN/DP CPU All versions V3.X.17, SIMATIC ET 200S IM151-8F...
Design/Logic Flaw
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules All versions , DIGSI 5 engineering software All versions V7.90, SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87,...
CVE-2019-10931