CVE-2017-6030 Schneider Electric Modicon PLCs Predictable Value Range from Previous Values
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
CVE-2017-6030
CVE-2017-6030 affects Schneider Electric Modicon PLCs (M221, M241, M251) with firmware versions prior to 1.5.0.0 (M221) and prior to 4.0.5.11 (M241/M251). The issue is a Predictable Value Range from Previous Values causing insufficiently random TCP initial sequence numbers, enabling an attacker t...
CVE-2017-6030 Schneider Electric Modicon PLCs Predictable Value Range from Previous Values
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
CVE-2017-7898
CVE-2017-7898 affects Rockwell Automation Allen-Bradley MicroLogix 1100 controllers (1763-L16A… series) and MicroLogix 1400 controllers (1766-L32A… series) with firmware 16.00 or earlier. The root cause is an improper restriction of excessive authentication attempts (CWE-307): there are no penalt...
CVE-2017-6028
Schneider Electric Modicon PLCs Modicon M241 (all firmware) and M251 (all firmware) are affected by CVE-2017-6028, where login credentials are transmitted over the network using Base64, enabling sniffing and potential unauthorized web access. No exploits are publicly known in the provided docs. R...
CVE-2017-6028
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...
CVE-2017-7899
An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00...
EtherNet/IP Detection (TCP)
A EtherNet/IP Service is running at this host. EtherNet/IP is an industrial network protocol that adapts the Common Industrial Protocol to standard Ethernet. It is widely used in a range industries including factory, hybrid and process to manage the connection between various automation devices...
Schneider Electric Modicon M221 PLCs and SoMachine Basic
CVSS v3 10.0 ATTENTION: Remotely exploitable/low skill level to exploit. Public exploits are available. Vendor: Schneider Electric Equipment: Modicon M221 PLCs and SoMachine Basic Vulnerability: Use of Hard-Coded Cryptographic Key, Protection Mechanism Failure AFFECTED PRODUCTS Schneider Electric...
Schneider Electric Modicon M221 PLCs and SoMachine Basic (Update A)
CVSS v3 10.0 ATTENTION: Remotely exploitable/low skill level to exploit. Public exploits are available. Vendor: Schneider Electric Equipment: Modicon M221 PLCs and SoMachine Basic Vulnerability: Use of Hard-Coded Cryptographic Key, Protection Mechanism Failure UPDATE INFORMATION This updated...
Schneider Electric Modicon PLCs
CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: Modicon PLCs Vulnerability: Predictable Value Range from Previous Values, Use of Insufficiently Random Values, Insufficiently Protected Credentials AFFECTED PRODUCTS The following version...
This Ransomware Malware Could Poison Your Water Supply If Not Paid
Ransomware has been around for a few years, but in last two years, it has become an albatross around everyone's neck, targeting businesses, hospitals, financial institutions and personal computers worldwide and extorting millions of dollars. Ransomware is a type of malware that infects computers...
Phoenix Contact ILC Information Disclosure Vulnerability
Phoenix Contact ProConOs and MultiProg are programmable logic controllers PLCs for use in industrial PCs from the Phoenix Contact group. An information disclosure vulnerability exists in Phoenix Contact ILC PLCs due to sensitive information being stored in clear text. An attacker could exploit th...
Undocumented SNMP String Exposes Rockwell PLCs to Remote Attacks
An undocumented SNMP community string has been discovered in programmable logic controllers PLCs built by Allen-Bradley Rockwell Automation that exposes these devices deployed in a number of critical industries to remote attacks. Researchers at Cisco Talos today said the vulnerability is in the...
PLC Blaster Worm Targets Industrial Control PLCs
LAS VEGAS – Security researchers at Black Hat USA described a proof-of-concept worm that targets weaknesses within automated industrial control systems used to manage critical infrastructure and manufacturing. The worm, according to OpenSource Security, has the capability to autonomously search f...
91 Percent of Public-Facing ICS Components Are Remotely Exploitable
We live in an increasingly connected world, but even in an age when DDoS attacks can take entire airlines offline, many critically sensitive industrial control systems ICS are still connected to the internet. A pair of reports released today by Kaspersky Lab reveal how dire the situation really i...
Wago Shell
Added: 03/31/2016 Background Wago PLCs are used in Factory and building automation. Wago ethernet PLCs are connected by IP and can be administered remotely. Problem Wago PLC devices use CoDeSyS protocols to program the device. If the programming ports are left open an attacker is able to upload,...
Wago Shell
Added: 03/31/2016 Background Wago PLCs are used in Factory and building automation. Wago ethernet PLCs are connected by IP and can be administered remotely. Problem Wago PLC devices use CoDeSyS protocols to program the device. If the programming ports are left open an attacker is able to upload,...
Wago Shell
Added: 03/31/2016 Background Wago PLCs are used in Factory and building automation. Wago ethernet PLCs are connected by IP and can be administered remotely. Problem Wago PLC devices use CoDeSyS protocols to program the device. If the programming ports are left open an attacker is able to upload,...
Siemens SIMATIC S7-1200 CSRF Vulnerability
OVERVIEW Siemens has identified an CSRF Cross-Site Request Forgery vulnerability in the SIMATIC S7‑1200 CPUs. This vulnerability was reported directly to Siemens by Ralf Spenneberg, Hendrik Schwartke, and Maik Brüggemann from OpenSource Training. Siemens has produced a firmware update to mitigate...