Lucene search
+L

323 matches found

Vulnrichment
Vulnrichment
added 2017/06/30 2:35 a.m.4 views

CVE-2017-6030 Schneider Electric Modicon PLCs Predictable Value Range from Previous Values

A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...

6.5AI score0.02124EPSS
Exploits0References3
CVE
CVE
added 2017/06/30 2:35 a.m.91 views

CVE-2017-6030

CVE-2017-6030 affects Schneider Electric Modicon PLCs (M221, M241, M251) with firmware versions prior to 1.5.0.0 (M221) and prior to 4.0.5.11 (M241/M251). The issue is a Predictable Value Range from Previous Values causing insufficiently random TCP initial sequence numbers, enabling an attacker t...

6.5CVSS6.6AI score0.02124EPSS
Exploits0References3Affected Software1
Cvelist
Cvelist
added 2017/06/30 2:35 a.m.26 views

CVE-2017-6030 Schneider Electric Modicon PLCs Predictable Value Range from Previous Values

A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...

6.3AI score0.02124EPSS
Exploits0References3
CVE
CVE
added 2017/06/30 2:35 a.m.91 views

CVE-2017-7898

CVE-2017-7898 affects Rockwell Automation Allen-Bradley MicroLogix 1100 controllers (1763-L16A… series) and MicroLogix 1400 controllers (1766-L32A… series) with firmware 16.00 or earlier. The root cause is an improper restriction of excessive authentication attempts (CWE-307): there are no penalt...

9.8CVSS9.3AI score0.0511EPSS
Exploits0References2Affected Software8
CVE
CVE
added 2017/06/30 2:35 a.m.89 views

CVE-2017-6028

Schneider Electric Modicon PLCs Modicon M241 (all firmware) and M251 (all firmware) are affected by CVE-2017-6028, where login credentials are transmitted over the network using Base64, enabling sniffing and potential unauthorized web access. No exploits are publicly known in the provided docs. R...

9.8CVSS9.3AI score0.0225EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2017/06/30 2:35 a.m.26 views

CVE-2017-6028

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...

9.4AI score0.0225EPSS
Exploits0References2
Cvelist
Cvelist
added 2017/06/30 2:35 a.m.28 views

CVE-2017-7899

An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00...

9.3AI score0.04619EPSS
Exploits0References2
OpenVAS
OpenVAS
added 2017/06/09 12:0 a.m.118 views

EtherNet/IP Detection (TCP)

A EtherNet/IP Service is running at this host. EtherNet/IP is an industrial network protocol that adapts the Common Industrial Protocol to standard Ethernet. It is widely used in a range industries including factory, hybrid and process to manage the connection between various automation devices...

7AI score
Exploits0
ICS
ICS
added 2017/04/13 12:0 a.m.161 views

Schneider Electric Modicon M221 PLCs and SoMachine Basic

CVSS v3 10.0 ATTENTION: Remotely exploitable/low skill level to exploit. Public exploits are available. Vendor: Schneider Electric Equipment: Modicon M221 PLCs and SoMachine Basic Vulnerability: Use of Hard-Coded Cryptographic Key, Protection Mechanism Failure AFFECTED PRODUCTS Schneider Electric...

9.8CVSS0.2AI score0.03981EPSS
Exploits1References29
ICS
ICS
added 2017/04/13 12:0 a.m.70 views

Schneider Electric Modicon M221 PLCs and SoMachine Basic (Update A)

CVSS v3 10.0 ATTENTION: Remotely exploitable/low skill level to exploit. Public exploits are available. Vendor: Schneider Electric Equipment: Modicon M221 PLCs and SoMachine Basic Vulnerability: Use of Hard-Coded Cryptographic Key, Protection Mechanism Failure UPDATE INFORMATION This updated...

10CVSS9.8AI score0.03981EPSS
Exploits1References3
ICS
ICS
added 2017/03/30 12:0 a.m.73 views

Schneider Electric Modicon PLCs

CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: Modicon PLCs Vulnerability: Predictable Value Range from Previous Values, Use of Insufficiently Random Values, Insufficiently Protected Credentials AFFECTED PRODUCTS The following version...

9.1CVSS8.6AI score0.3182EPSS
Exploits5References3
The Hacker News
The Hacker News
added 2017/02/16 10:14 p.m.12 views

This Ransomware Malware Could Poison Your Water Supply If Not Paid

Ransomware has been around for a few years, but in last two years, it has become an albatross around everyone's neck, targeting businesses, hospitals, financial institutions and personal computers worldwide and extorting millions of dollars. Ransomware is a type of malware that infects computers...

7.1AI score
Exploits0
CNVD
CNVD
added 2016/11/10 12:0 a.m.57 views

Phoenix Contact ILC Information Disclosure Vulnerability

Phoenix Contact ProConOs and MultiProg are programmable logic controllers PLCs for use in industrial PCs from the Phoenix Contact group. An information disclosure vulnerability exists in Phoenix Contact ILC PLCs due to sensitive information being stored in clear text. An attacker could exploit th...

7.3CVSS6.1AI score0.05845EPSS
Exploits4References1
ThreatPost
ThreatPost
added 2016/08/12 1:0 p.m.21 views

Undocumented SNMP String Exposes Rockwell PLCs to Remote Attacks

An undocumented SNMP community string has been discovered in programmable logic controllers PLCs built by Allen-Bradley Rockwell Automation that exposes these devices deployed in a number of critical industries to remote attacks. Researchers at Cisco Talos today said the vulnerability is in the...

1.8AI score
Exploits0References2
ThreatPost
ThreatPost
added 2016/08/05 4:49 p.m.47 views

PLC Blaster Worm Targets Industrial Control PLCs

LAS VEGAS – Security researchers at Black Hat USA described a proof-of-concept worm that targets weaknesses within automated industrial control systems used to manage critical infrastructure and manufacturing. The worm, according to OpenSource Security, has the capability to autonomously search f...

6.4CVSS1.6AI score0.01691EPSS
Exploits0References2
ThreatPost
ThreatPost
added 2016/07/11 8:32 a.m.12 views

91 Percent of Public-Facing ICS Components Are Remotely Exploitable

We live in an increasingly connected world, but even in an age when DDoS attacks can take entire airlines offline, many critically sensitive industrial control systems ICS are still connected to the internet. A pair of reports released today by Kaspersky Lab reveal how dire the situation really i...

0.2AI score
Exploits0References14
Saint
Saint
added 2016/03/31 12:0 a.m.45 views

Wago Shell

Added: 03/31/2016 Background Wago PLCs are used in Factory and building automation. Wago ethernet PLCs are connected by IP and can be administered remotely. Problem Wago PLC devices use CoDeSyS protocols to program the device. If the programming ports are left open an attacker is able to upload,...

7.5AI score
Exploits0
Saint
Saint
added 2016/03/31 12:0 a.m.42 views

Wago Shell

Added: 03/31/2016 Background Wago PLCs are used in Factory and building automation. Wago ethernet PLCs are connected by IP and can be administered remotely. Problem Wago PLC devices use CoDeSyS protocols to program the device. If the programming ports are left open an attacker is able to upload,...

0.5AI score
Exploits0
Saint
Saint
added 2016/03/31 12:0 a.m.38 views

Wago Shell

Added: 03/31/2016 Background Wago PLCs are used in Factory and building automation. Wago ethernet PLCs are connected by IP and can be administered remotely. Problem Wago PLC devices use CoDeSyS protocols to program the device. If the programming ports are left open an attacker is able to upload,...

7.5AI score
Exploits0
ICS
ICS
added 2015/05/30 6:0 a.m.168 views

Siemens SIMATIC S7-1200 CSRF Vulnerability

OVERVIEW Siemens has identified an CSRF Cross-Site Request Forgery vulnerability in the SIMATIC S7‑1200 CPUs. This vulnerability was reported directly to Siemens by Ralf Spenneberg, Hendrik Schwartke, and Maik Brüggemann from OpenSource Training. Siemens has produced a firmware update to mitigate...

7.5CVSS7AI score0.03339EPSS
Exploits2References10
Rows per page
Query Builder