Lucene search
+L

3077 matches found

CVE
CVE
added 2022/04/04 7:45 p.m.73 views

CVE-2021-32978

The CVE-2021-32978 entry describes a vulnerability in Automation Direct CLICK PLC CPU Modules (C0-1x) with firmware prior to v3.00 where a previously entered password and lock state can be read from the programming protocol, effectively exposing credentials and enabling unlocks if the password wa...

7.5CVSS7.6AI score0.0101EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/04 7:45 p.m.34 views

CVE-2021-32978 Automation Direct CLICK PLC CPU Modules Plaintext Storage of a Password

The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00...

7.5CVSS7.7AI score0.0101EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2022/04/04 7:45 p.m.6 views

CVE-2021-32978 Automation Direct CLICK PLC CPU Modules Plaintext Storage of a Password

The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00...

7.5CVSS7AI score0.0101EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/04/04 7:45 p.m.31 views

CVE-2021-32980 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS9.6AI score0.01113EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/04 7:45 p.m.114 views

CVE-2021-32980

CVE-2021-32980 affects Automation Direct CLICK PLC CPU Modules, specifically the C0-1x CPUs with firmware older than 3.00. The issue is an authentication bypass via an alternate path or channel, caused by the firmware not protecting against additional software programming connections. An attacker...

9.8CVSS9.5AI score0.01113EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2022/04/04 7:45 p.m.10 views

CVE-2021-32980 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS6.9AI score0.01113EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2022/04/04 12:00 a.m.8 views

PT-2022-10178 · Automationdirect · Automation Direct Click Plc Cpu Modules

Name of the Vulnerable Software and Affected Versions: Automation Direct CLICK PLC CPU Modules: C0-1x CPUs versions prior to v3.00 Description: The issue arises when an authorized user unlocks the Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. The unlocked state...

9.8CVSS9.2AI score0.01113EPSS
SaveExploits0References3
The Hacker News
The Hacker News
added 2022/04/01 12:31 p.m.61 views

Critical Bugs in Rockwell PLC Could Allow Hackers to Implant Malicious Code

Two new security vulnerabilities have been disclosed in Rockwell Automation's programmable logic controllers PLCs and engineering workstation software that could be exploited by an attacker to inject malicious code on affected systems and stealthily modify automation processes. The flaws have the...

10CVSS1.6AI score0.05133EPSS
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2022/03/21 12:00 a.m.81 views

Siemens SIMATIC Industrial Products Missing Release of Memory After Effective Lifetime (CVE-2021-37205)

A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial- of-service condition in a PL...

7.5CVSS7.2AI score0.0164EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/03/21 12:00 a.m.72 views

Siemens SIMATIC Industrial Products Operation On a Resource After Expiration or Release (CVE-2021-37204)

A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial-of-service condition in a PLC...

7.5CVSS7.2AI score0.02181EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/03/21 12:00 a.m.70 views

Siemens SIMATIC Industrial Products Operation On a Resource After Expiration or Release (CVE-2021-37185)

A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial- of-service condition in a PL...

7.5CVSS7.2AI score0.0206EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2022/03/16 12:00 a.m.10 views

The vulnerability of the development environment “CX-Programmer,” which is part of the software suite “CX-One” designed for programming and configuring Omron PLCs, arises from reading data from within allowable buffer limits. This allows attackers to disclose sensitive information or execute arbitrary code.

The vulnerability of the development environment provided by CX-Programmer, which is part of the CX-One software suite designed for programming and configuring Omron PLCs, relates to the use of memory after it is freed. Exploiting this vulnerability can allow an attacker to disclose sensitive...

7.8CVSS7.2AI score0.01025EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2022/03/16 12:00 a.m.11 views

The vulnerability of the development environment “CX-Programmer,” which is part of the software suite “CX-One” designed for programming and configuring Omron PLCs, stems from the use of memory after it has been freed. This allows a malicious actor to execute arbitrary code.

The vulnerability of the development environment provided by CX-Programmer, which is part of the CX-One software suite designed for programming and configuring Omron PLCs, relates to the use of memory after it is freed. Exploiting this vulnerability can allow an attacker to execute arbitrary code...

7.8CVSS7.6AI score0.01077EPSS
SaveExploits0References3Affected Software1
zdt
zdt
added 2022/03/10 12:00 a.m.410 views

Siemens S7-1200 - Unauthenticated Start / Stop Command Vulnerability

Exploit Title: Unauthenticated Siemens S7-1200 CPU Start/Stop Command Exploit Author: RoseSecurity Vendor Homepage: https://www.siemens.com/global/en.html Version: V4.5 and below Tested on: Siemens S7-1200 CPU: 1215C IP == PLC IP address Start Command curl -i -s -k -X $'POST' \ -H $'Host: ' -H...

0.5AI score
SaveExploits0
ICS
ICS
added 2022/03/04 12:00 a.m.78 views

Trailer Power Line Communications (PLC) J2497

1. EXECUTIVE SUMMARY CVSS v3 9.3 ATTENTION: Exploitable remotely/low attack complexity Equipment: Power Line Communications PLC: J2497 a.k.a. PLC4TRUCKS Vulnerabilities: Missing Authentication for Critical Function, Improper Protection against Electromagnetic Fault Injection 2. RISK EVALUATION...

9.1CVSS9.8AI score0.01191EPSS
SaveExploits0References4
CNVD
CNVD
added 2022/02/15 12:00 a.m.65 views

Schneider Electric Multiple Product Input Validation Error Vulnerability

Schneider Electric Modicon Quantum and Schneider Electric Modicon M340 are both products of Schneider Electric, a French company. The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure. The vulnerability sends a specially...

7.5CVSS1.7AI score0.01037EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/15 12:00 a.m.74 views

Schneider Electric Multiple Product Information Breach Vulnerability

Schneider Electric Modicon Quantum is a large programmable logic controller PLC for process applications, high availability and safety solutions. Schneider Electric Modicon M340 is a medium-range PLC programmable logic controller for industrial processes and infrastructure. An information...

7.5CVSS0.4AI score0.00962EPSS
SaveExploits0References1
Openbugbounty
Openbugbounty
added 2022/02/14 12:04 a.m.12 views

plc-em.ru Cross Site Scripting vulnerability OBB-2371248

Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...

6.2AI score
SaveExploits0
CNVD
CNVD
added 2022/02/10 12:00 a.m.52 views

Schneider Electric Modicon M340 CPUs Resource Management Error Vulnerability

Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. The vulnerability can be exploited to send a large number of TCP RST or FIN packets to any open TCP port of the PLC, resulting in a denial ...

7.5CVSS1.5AI score0.0093EPSS
SaveExploits0References1
NVD
NVD
added 2022/02/09 4:15 p.m.37 views

CVE-2021-37205

A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial-of-service condition in a PLC...

7.5CVSS0.0164EPSS
SaveExploits0References1
Rows per page