3070 matches found
Schneider Electric Product Authorization Issue Vulnerability
The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructures from Schneider Electric France. An authorization issue vulnerability exists in the Schneider Electric product that stems from the presence of improper privilege...
CVE-2022-2791
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-434 Unrestricted Upload of File with Dangerous Type, and will upload any file written into the PLC logic folder to the connected PLC...
Design/Logic Flaw
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-434 Unrestricted Upload of File with Dangerous Type, and will upload any file written into the PLC logic folder to the connected PLC...
CVE-2022-2791
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-434 Unrestricted Upload of File with Dangerous Type, and will upload any file written into the PLC logic folder to the connected PLC...
CVE-2022-2791
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-434 Unrestricted Upload of File with Dangerous Type, and will upload any file written into the PLC logic folder to the connected PLC...
WAGO 安全漏洞
WAGO is a 750-88x series programmable logic controller from WAGO, Germany. The device is designed for use in industrial environments as an electronic system for the operation of digital algorithms. A security vulnerability exists in the WAGO I/O-Check Service that originates from an unauthenticat...
CVE-2022-36363
A vulnerability has been identified in LOGO! 12/24RCE 6ED1052-1MD08-0BA1 All versions, LOGO! 12/24RCEo 6ED1052-2MD08-0BA1 All versions, LOGO! 230RCE 6ED1052-1FB08-0BA1 All versions, LOGO! 230RCEo 6ED1052-2FB08-0BA1 All versions, LOGO! 24CE 6ED1052-1CC08-0BA1 All versions, LOGO! 24CEo...
PT-2022-7652 · Siemens · Logo! 230Rce +6
Name of the Vulnerable Software and Affected Versions: LOGO! 12/24RCE versions 6ED1052-1MD08-0BA1 LOGO! 12/24RCEo versions 6ED1052-2MD08-0BA1 LOGO! 230RCE versions 6ED1052-1FB08-0BA1 LOGO! 230RCEo versions 6ED1052-2FB08-0BA1 LOGO! 24CE versions 6ED1052-1CC08-0BA1 LOGO! 24CEo versions...
CVE-2022-36363
A vulnerability has been identified in LOGO! 12/24RCE 6ED1052-1MD08-0BA1 All versions, LOGO! 12/24RCEo 6ED1052-2MD08-0BA1 All versions, LOGO! 230RCE 6ED1052-1FB08-0BA1 All versions, LOGO! 230RCEo 6ED1052-2FB08-0BA1 All versions, LOGO! 24CE 6ED1052-1CC08-0BA1 All versions, LOGO! 24CEo...
WAGO Series 750-88x and 750-352 Uncontrolled Resource Consumption (CVE-2020-12516)
Older firmware versions FW1 up to FW10 of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack. - Older firmware versions FW1 up to FW10 of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack. CVE-2020-12516 This...
InTouch Access Anywhere Secure Gateway 2020 R2 Path Traversal
Title: ====== AVEVA InTouch Access Anywhere Secure Gateway - Path Traversal Author: ======= Jens Regel, CRISEC IT-Security CVE: ==== CVE-2022-23854 Advisory: ========= https://crisec.de/advisory-aveva-intouch-access-anywhere-secure-gateway-path-traversal/ Timeline: ========= 25.06.2021...
CVE-2022-2004
AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to...
CVE-2022-2003
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC...
Hardcoded credentials
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of...
Design/Logic Flaw
AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to...
Design/Logic Flaw
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC...
CVE-2022-2003
CVE-2022-2003 affects AutomationDirect DirectLOGIC D0-06 series CPUs (D0-06DD1/2/DR/DA/AR/AA and variants) with serial communication prior to firmware version 2.72. Root cause: a specially crafted serial message to the CPU serial port elicits the PLC to respond with the PLC password in cleartext,...
CVE-2022-2004
The CVE-2022-2004 issue affects AutomationDirect DirectLOGIC D0-06 series CPUs (including D0-06DD1/2/DR/DA/AR/AA and related D0-06DD1-D/D- variants) prior to firmware version 2.72. A specially crafted network packet can exhaust resources in Ethernet modules (H0-ECOM/H0-ECOM100 and related hardwar...
PT-2022-18501 · Ls Electric · Xgb-Xbch +6
Name of the Vulnerable Software and Affected Versions: LS Electric XG5000 software versions prior to V4.0 LS Electric PLCs: XGK-CPUU/H/A/S/E versions prior to V3.50 XGI-CPUU/UD/H/S/E versions prior to V3.20 XGR-CPUH versions prior to V1.80 XGB-XBMS versions prior to V3.00 XGB-XBCH versions prior ...
CVE-2022-2788
Emerson Electric's Proficy Machine Edition Version 9.80 and prior is vulnerable to CWE-29 Path Traversal: '..\Filename', also known as a ZipSlip attack, through an upload procedure which enables attackers to implant a malicious .BLZ file on the PLC. The file can transfer through the engineering...