3068 matches found
CVE-2024-50956
A buffer overflow in the RecvSocketData function of Inovance HCPLCAM401-CPU1608TPTN 21.38.0.0, HCPLCAM402-CPU1608TPTN 41.38.0.0, and HCPLCAM403-CPU1608TN 81.38.0.0 allows attackers to cause a Denial of Service DoS or execute arbitrary code via a crafted Modbus message...
CVE-2023-41374
Double free issue exists in Kostac PLC Programming Software Version 1.6.11.0 and earlier. Arbitrary code may be executed by having a user open a specially crafted project file which was saved using Kostac PLC Programming Software Version 1.6.9.0 and earlier because the issue exists in parsing of...
CVE-2023-41375
Use after free vulnerability exists in Kostac PLC Programming Software Version 1.6.11.0. Arbitrary code may be executed by having a user open a specially crafted project file which was saved using Kostac PLC Programming Software Version 1.6.9.0 and earlier because the issue exists in parsing of K...
CVE-2023-22424
Use-after-free vulnerability exists in Kostac PLC Programming Software Former name: Koyo PLC Programming Software Version 1.6.9.0 and earlier. With the abnormal value given as the maximum number of columns for the PLC program, the process accesses the freed memory. As a result, opening a speciall...
CVE-2023-22421
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software Former name: Koyo PLC Programming Software Version 1.6.9.0 and earlier. The insufficient buffer size for the PLC program instructions leads to out-of-bounds read. As a result, opening a specially crafted project file may...
CVE-2023-22419
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software Former name: Koyo PLC Programming Software Version 1.6.9.0 and earlier. When processing a comment block in stage information, the end of data cannot be verified and out-of-bounds read occurs. As a result, opening a special...
CVE-2022-2791
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-434 Unrestricted Upload of File with Dangerous Type, and will upload any file written into the PLC logic folder to the connected PLC...
CVE-2021-32986
After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without...
CVE-2021-27477
When JTEKT Corporation TOYOPUC PLC versions PC10G-CPU, 2PORT-EFR, Plus CPU, Plus EX, Plus EX2, Plus EFR, Plus EFR2, Plus 2P-EFR, PC10P-DP, PC10P-DP-IO, Plus BUS-EX, Nano 10GX, Nano 2ET,PC10PE, PC10PE-16/16P, PC10E, FL/ET-T-V2H, PC10B,PC10B-P, Nano CPU, PC10P, and PC10GE receive an invalid frame,...
CVE-2021-20827
Plaintext storage of a password vulnerability in IDEC PLCs FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier allows an...
CVE-2021-37401
An attacker may obtain the user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the PLC user program may be uploaded, altered, and/or downloaded...
CVE-2021-37172
A vulnerability has been identified in SIMATIC S7-1200 CPU family incl. SIPLUS variants V4.5.0. Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication an...
CVE-2021-32984
All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project...
CVE-2021-32978
The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00...
CVE-2021-32982
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange...
CVE-2021-37400
An attacker may obtain the user credentials from the communication between the PLC and the software. As a result, the PLC user program may be uploaded, altered, and/or downloaded...
CVE-2021-32980
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...
CVE-2020-28213
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause unauthorized command execution when sending specially crafted requests over Modbus...