3077 matches found
CVE-2019-1010136
ChinaMobile GPN2.4P21-C-CN W2001EN-00 is affected by: Incorrect Access Control - Unauthenticated Remote Reboot. The impact is: PLC Wireless Router's are vulnerable to an unauthenticated remote reboot due. The component is: Reboot settings are available to unauthenticated users instead of only...
Design/Logic Flaw
ChinaMobile GPN2.4P21-C-CN W2001EN-00 is affected by: Incorrect Access Control - Unauthenticated Remote Reboot. The impact is: PLC Wireless Router's are vulnerable to an unauthenticated remote reboot due. The component is: Reboot settings are available to unauthenticated users instead of only...
CVE-2019-1010136
ChinaMobile GPN2.4P21-C-CN W2001EN-00 is affected by: Incorrect Access Control - Unauthenticated Remote Reboot. The impact is: PLC Wireless Router's are vulnerable to an unauthenticated remote reboot due. The component is: Reboot settings are available to unauthenticated users instead of only...
Privilege Bypass Vulnerability in Schneider Electric P3420 PLC Module
Schneider Electric Modicon M340 PLC is a programmable controller product of Schneider Electric France. A privilege bypass vulnerability exists in the Schneider Electric P3420 PLC module. An attacker can cause the PLC to start and stop by constructing PLC start-stop data messages using private...
Denial of Service Vulnerability in Omron CJ2M-CPU31
CJ2M-CPU31 is a programmable logic controller PLC A denial of service vulnerability exists in the Omron CJ2M-CPU31, which can be exploited by an attacker to cause CPU resource exhaustion by sending specific packets to the target PLC on a continuous basis...
Schneider Electric BMXP342030H M340 PLC Detection
Binary data 764544.prm...
Schneider Electric BMXP3420302H M340 PLC Detection
Binary data 764543.prm...
Schneider Electric BMXP342020H M340 PLC Detection
Binary data 764542.prm...
Siemens SIMATIC S7 200 SMART 6ES7288-1ST40-0AA0 PLC
Binary data 764659.prm...
Siemens SIMATIC WinAC RTX F 2010 Software PLC
Binary data 764665.prm...
Siemens SIMATIC WinAC RTX 2010 Software PLC
Binary data 764664.prm...
Siemens SIMATIC WinAC RTX 2010 Software PLC
Binary data 764663.prm...
Schneider Electric Modicon Controllers
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Schneider Electric Equipment: Modicon Controllers Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could result...
CVE-2019-10998
CVE-2019-10998 affects Phoenix Contact PLCNext AXC F 2152 (article numbers 2404267 and 1046568 Starterkit) with firmware versions prior to 2019.0 LTS. The issue is an improper access control that, when there is unlimited physical access, can lead to manipulation of SD card data and an authenticat...
The vulnerability of the microprogrammed programmable logic controller Modicon Quantum, related to errors in access control mechanisms, allows a intruder to trigger a service failure or alter the controller’s configuration.
The vulnerability of the microprogrammed programmable logic controller Modicon Quantum is related to errors in the access control mechanisms. Exploiting this vulnerability could allow an attacker to cause service failures or modify the controller’s configuration using the Ethernet/IP protocol...
The vulnerability of the microprogrammed programmable logic controller Modicon, related to the disclosure of information, allows a intruder to gain access to confidential data.
The vulnerability of the microprogrammed programmable logic controller Modicon relates to the disclosure of information. Exploiting this vulnerability can allow an intruder, operating remotely, to gain access to confidential SNMP protocol information when reading variables in the controller using...
CVE-2019-10997
An issue was discovered on Phoenix Contact AXC F 2152 No.2404267 before 2019.0 LTS and AXC F 2152 STARTERKIT No.1046568 before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be...
CVE-2019-10997
An issue was discovered on Phoenix Contact AXC F 2152 No.2404267 before 2019.0 LTS and AXC F 2152 STARTERKIT No.1046568 before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be...
Code injection
An issue was discovered on Phoenix Contact AXC F 2152 No.2404267 before 2019.0 LTS and AXC F 2152 STARTERKIT No.1046568 before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be...
CVE-2019-10997
CVE-2019-10997 affects Phoenix Contact PLCNext AXC F 2152 family (article 2404267) and Starterkit (1046568) prior to firmware 2019.0 LTS. The issue arises from a man-in-the-middle scenario where protocol fuzzing on PC WORX Engineer can cause the PLC service to stop, requiring a reboot or manual r...