Lucene search
+L

3077 matches found

CVE
CVE
added 2019/10/29 2:48 p.m.89 views

CVE-2019-6843

CVE-2019-6843 affects Schneider Electric Modicon controllers: M580 (firmware before v3.10), M340 (all firmware versions), and BMxCRA/140CRA (all firmware). The root cause is an improper handling during FTP-based firmware upgrades, where an empty firmware image can trigger a recoverable fault, cau...

4.9CVSS4.9AI score0.00959EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/10/29 2:48 p.m.35 views

CVE-2019-6843

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware version prior to V3.10, Modicon M340 all firmware versions, and Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service attack on the PLC when upgrading...

5AI score0.00959EPSS
SaveExploits0References1
CVE
CVE
added 2019/10/29 2:47 p.m.110 views

CVE-2019-6842

CVE-2019-6842 affects Schneider Electric Modicon M580, M340, BMxCRA, and 140CRA firmware. The root cause is improper handling of exceptional conditions in FTP-based firmware upgrade flows, which can cause a Denial of Service, stopping normal device execution after upgrade when the web server imag...

4.9CVSS5.1AI score0.00959EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2019/10/29 2:46 p.m.80 views

CVE-2019-6841

CVE-2019-6841 affects Schneider Electric Modicon M580 (firmware SV2.80 up to pre-V3.10), M340 (all firmware), and BMxCRA/140CRA modules (all firmware). The issue is a CWE-755 improper handling of exceptional conditions that can cause a Denial of Service when upgrading firmware via FTP with no fir...

4.9CVSS5AI score0.24374EPSS
SaveExploits0References1Affected Software1
CNVD
CNVD
added 2019/10/23 12:00 a.m.3 views

Denial of Service Vulnerability in Siemens 1200 PLCs

The Siemens 1200 PLC is a modular general-purpose controller from Siemens for the manufacturing industry. A denial of service vulnerability exists in the Siemens 1200 PLC that can be exploited by an attacker to cause a denial of service...

6.7AI score
SaveExploits0
Talos
Talos
added 2019/10/08 12:00 a.m.186 views

Schneider Electric Modicon M580 UMAS REST API getcominfo denial-of-service vulnerability

Summary An exploitable denial of service vulnerability exists in the UMAS REST API getcominfo functionality of the Schneider Electric Modicon M580 Programmable Automation Controller firmware version SV2.80. A specially crafted HTTP request can cause the device to enter a non-recoverable fault...

8.6CVSS8.6AI score0.32974EPSS
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/10/07 12:00 a.m.16 views

Siemens LOGO! 24CE PLC Detection

Binary data 765135.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/10/07 12:00 a.m.12 views

Siemens LOGO!8 BM PLC Missing Authentication and Plaintext Storage of a Password (ICSA-19-134-04)

Binary data 720307.prm...

9.4CVSS7.3AI score0.02746EPSS
SaveExploits3References2
Tenable Nessus
Tenable Nessus
added 2019/10/07 12:00 a.m.31 views

Siemens LOGO!8 PLC < 1.82.02 Improper Restriction within Memory Buffer or Session Fixation DoS (ICSA-19-162-03)

Binary data 720304.prm...

7.8CVSS7.3AI score0.01599EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/10/07 12:00 a.m.20 views

Siemens LOGO! 230RCE PLC Detection

Binary data 765138.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/10/07 12:00 a.m.20 views

Siemens LOGO! 24RCE PLC Detection

Binary data 765137.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/10/07 12:00 a.m.33 views

Siemens LOGO! 12/24RCE PLC Detection

Binary data 765136.prm...

7.3AI score
SaveExploits0
CNVD
CNVD
added 2019/10/03 12:00 a.m.8 views

Certification Bypass Vulnerability in SIEMENS SIMATIC S7-200 Smart PLCs

Siemens is a leading global technology company providing solutions for customers in the areas of power generation and transmission and distribution, infrastructure, industrial automation, drives and software through innovations in electrification, automation and digitalization. An authentication...

7AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/09/19 12:00 a.m.11 views

Siemens S7-200 Series PLC Detection

Binary data 765116.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/09/19 12:00 a.m.7 views

Siemens S7-1500 Series PLC Detection

Binary data 765120.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/09/19 12:00 a.m.14 views

Siemens S7-300 Series PLC Detection

Binary data 765117.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/09/17 12:00 a.m.16 views

Schneider Electric BMEP584040 M580 PLC Detection

Binary data 765047.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/09/17 12:00 a.m.12 views

Schneider Electric BMEH586040 M580 Redundant PLC Detection

Binary data 765057.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/09/17 12:00 a.m.16 views

Schneider Electric BMXP341000 M340 PLC Detection

Binary data 765043.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/09/17 12:00 a.m.13 views

Schneider Electric BMEP586040C M580 Conformally Coated PLC Detection

Binary data 765056.prm...

7.3AI score
SaveExploits0