Lucene search
K

9 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2014-2288

Malware in sbrugna...

5.8CVSS6.1AI score0.00181EPSS
Exploits1References7
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2014-2294

Malware in sbrugna...

7.8CVSS6.1AI score0.01597EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2014-2295

Malware in sbrugna...

7.8CVSS6.2AI score0.00902EPSS
Exploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.13 views

Siemens SIMATIC S7-1500 Improper Input Validation (CVE-2014-2259)

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...

7.8CVSS5.5AI score0.01597EPSS
Exploits0References4
NVD
NVD
added 2015/10/06 1:59 a.m.12 views

CVE-2015-0987

Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the network during a PLC unlock request...

10CVSS6.4AI score0.00735EPSS
Exploits1References1
Prion
Prion
added 2015/10/06 1:59 a.m.11 views

Design/Logic Flaw

The HTTP application on Mitsubishi Electric MELSEC FX3G PLC devices before April 2015 allows remote attackers to cause a denial of service device outage via a long parameter...

7.8CVSS7.2AI score0.00459EPSS
Exploits1References1
Cvelist
Cvelist
added 2015/10/03 10:0 a.m.16 views

CVE-2015-0987

Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the network during a PLC unlock request...

6.4AI score0.00735EPSS
Exploits1References1
Prion
Prion
added 2014/03/16 2:6 p.m.9 views

Code injection

The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors...

8.3CVSS7AI score0.00902EPSS
Exploits0References3Affected Software1
Cvelist
Cvelist
added 2014/03/16 10:0 a.m.14 views

CVE-2014-2248

Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors...

6.7AI score0.0069EPSS
Exploits0References4
Rows per page
Query Builder