Lucene search
+L

9259 matches found

Intel
Intel
added 2018/07/10 12:00 a.m.19 views

Firmware Authentication Bypass

Summary: Potential security vulnerability allowing bypass of firmware authentication and incorrect TPM measurement of system firmware. Description: Platform sample code firmware included with 4th Gen Intel® Core™ Processor Haswell, 5th Gen Intel® Core™ Processor Broadwell, 6th Gen Intel® Core™...

1.6AI score
SaveExploits0
Intel
Intel
added 2018/07/09 12:00 a.m.19 views

DCI Policy Update

Summary: Intel is releasing Direct Connect Interface DCI policy update. Description: Existing UEFI setting restrictions for DCI Direct Connect Interface in 5th and 6th generation Intel® Xeon® Processor E3 Family, Intel® Xeon® Scalable processors, and Intel® Xeon® Processor D Family can potentiall...

7.3AI score
SaveExploits0
seebug.org
seebug.org
added 2018/07/05 12:00 a.m.71 views

DouPHP-多处物理路径泄露

...

0.8AI score
SaveExploits0
NVD
NVD
added 2018/07/03 1:29 a.m.32 views

CVE-2018-8870

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...

7.2CVSS6.6AI score0.00362EPSS
SaveExploits0References2
Prion
Prion
added 2018/07/03 1:29 a.m.25 views

Input validation

Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An...

6.9CVSS6.6AI score0.00333EPSS
SaveExploits0References1
Prion
Prion
added 2018/07/03 1:29 a.m.21 views

Hardcoded credentials

Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain...

7.2CVSS6.7AI score0.00362EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2018/07/03 1:29 a.m.5 views

CVE-2018-8870

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...

7.2CVSS5.5AI score0.00362EPSS
SaveExploits0References3
CVE
CVE
added 2018/07/02 6:00 p.m.63 views

CVE-2018-8870

CVE-2018-8870 affects Medtronic MyCareLink Monitors (models 24950 and 24952). The vulnerability is a hard-coded operating system password, enabling a physically proximate attacker who can open the device and connect via a debug port to gain privileged OS access. The ICS-CERT advisory corroborates...

7.2CVSS6.5AI score0.00362EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2018/07/02 6:00 p.m.33 views

CVE-2018-8868 Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit oth...

6.2CVSS6.6AI score0.00333EPSS
SaveExploits0References2
CNVD
CNVD
added 2018/07/02 12:00 a.m.10 views

Medtronic MyCareLink Patient Monitor Exposes Dangerous Method or Function Vulnerability

MyCareLink Patient Monitor is a patient monitor product developed by Medtronic, Inc. The Medtronic MyCareLink Patient Monitor has an Exposed Danger Method or Function vulnerability that can be exploited by an attacker with physical access to the device to access debugging functions of the monitor...

6.9CVSS6.4AI score0.00333EPSS
SaveExploits0References1
CNVD
CNVD
added 2018/07/02 12:00 a.m.7 views

Medtronic MyCareLink Patient Monitor Hardcoding Vulnerability

MyCareLink Patient Monitor is a patient monitor product developed by Medtronic, Inc. A hard-coded vulnerability in the Medtronic MyCareLink Patient Monitor allows an attacker with physical access to remove the device's enclosure, connect to the debug port, and use a password to gain privileged...

7.2CVSS6.7AI score0.00362EPSS
SaveExploits0References1
ICS
ICS
added 2018/06/28 12:00 a.m.46 views

Medtronic MyCareLink Patient Monitor

1. EXECUTIVE SUMMARY CVSS v3 6.4 Vendor: Medtronic Equipment: MyCareLink Patient Monitor Vulnerabilities: Use of Hard-coded Password, Exposed Dangerous Method or Function 2. RISK EVALUATION If exploited, these vulnerabilities may allow privileged access to the monitor’s operating system. However,...

7.2CVSS7.3AI score0.00362EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2018/06/27 12:00 a.m.30 views

RHEL 7 : dpdk (RHSA-2018:2038)

The remote Redhat Enterprise Linux 7 host has packages installed that are affected by a vulnerability as referenced in the RHSA-2018:2038 advisory. The dpdk packages provide the Data Plane Development Kit, which is a set of libraries and drivers for fast packet processing in the user space...

6.1CVSS6.6AI score0.00878EPSS
SaveExploits0References6
RedHat Linux
RedHat Linux
added 2018/06/26 7:01 p.m.11 views

dpdk: Information exposure in unchecked guest physical to host virtual address translations

The DPDK vhost-user interface does not check to verify that all the requested guest physical range is mapped and contiguous when performing Guest Physical Addresses to Host Virtual Addresses translations. This may lead to a malicious guest exposing vhost-user backend process memory...

6.1CVSS6.6AI score0.00878EPSS
SaveExploits0References4
seebug.org
seebug.org
added 2018/06/26 12:00 a.m.55 views

The Brickstream line of sensors provides highly accurate, anonymous information about how people move into, around, and out of physical places

The Brickstream line of sensors provides highly accurate, anonymous information about how people move into, around, and out of physical places Brickstream in ZoomEye: https://www.zoomeye.org/searchResult?q=%22%3Ctitle%3EBrickstream%22 ip info http://xx.xx.xx.xx/basic.htmlipsettings datadelivery...

1.8AI score
SaveExploits0
Prion
Prion
added 2018/06/25 2:29 a.m.24 views

Cross site request forgery (csrf)

The API service on Google Home and Chromecast devices before mid-July 2018 does not prevent DNS rebinding attacks from reading the scanresults JSON data, which allows remote attackers to determine the physical location of most web browsers by leveraging the presence of one of these devices on its...

3.3CVSS4.7AI score0.00696EPSS
SaveExploits0References4
Pen Test Partners Blog
Pen Test Partners Blog
added 2018/06/22 3:00 p.m.59 views

Hardware reverse engineering. A tale from the workbench

In line with our previous work on the Tapplock, I decided to have some fun with some electronic locks and ordered a few from a large retail company. Half of these are currently en route to me, on the slowboat from China, but one arrived early. Before I state, let me just say here that I’m not...

6.7AI score
SaveExploits0
Qualys Blog
Qualys Blog
added 2018/06/21 11:35 p.m.52 views

QSC18 Virtual Edition: Securing Hybrid IT Environments from Endpoints to Clouds

As organizations embrace digital transformation to boost business processes, traditional IT environments get altered, becoming distributed, elastic and hybrid. “That’s creating a new challenge for security,” Chris Carlson, Qualys’ Product Management VP, said during QSC18 Virtual Edition. As...

7.5AI score
SaveExploits0
Cisco
Cisco
added 2018/06/20 4:00 p.m.123 views

NVIDIA TX1 Boot ROM Vulnerability

On April 24, 2018, researchers disclosed a vulnerability that takes advantage of a buffer overflow vulnerability in NVIDIA TX1 BootROM when Recovery Mode RCM is active. This vulnerability could allow an unprivileged, local attacker to bypass secure boot and execute unverified code on an affected...

6.8CVSS6.8AI score0.0274EPSS
SaveExploits1References1
IBM Security Bulletins
IBM Security Bulletins
added 2018/06/18 12:09 a.m.24 views

Security Bulletin: Vulnerability in RC4 stream cipher affects the IBM Virtualization Engine TS7700 (CVE-2015-2808)

Summary The RC4 “Bar Mitzvah” Attack for SSL/TLS affects the IBM Virtualization Engine TS7700 Vulnerability Details CVEID: CVE-2015-2808 DESCRIPTION: The RC4 algorithm, as used in the TLS protocol and SSL protocol, could allow a remote attacker to obtain sensitive information. An attacker could...

5CVSS1.5AI score0.73851EPSS
SaveExploits0Affected Software5
Rows per page