9369 matches found
CVE-2024-41146
Use of Multiple Resources with Duplicate Identifier CWE-694 in the Controller 6000 and Controller 7000 Platforms could allow an attacker with physical access to HBUS communication cabling to perform a Denial-of-Service attack against HBUS connected devices, require a device reboot to resolve. Thi...
CVE-2024-41146
The CVE-2024-41146 affects Gallagher Controller 6000 and Controller 7000 platforms. The root cause is use of multiple resources with duplicate identifiers (CWE-694) in HBUS communications, which could allow a local attacker with physical access to HBUS cabling to trigger a Denial-of-Service on HB...
PT-2024-29294 · Unknown · Controller 6000 +1
Name of the Vulnerable Software and Affected Versions: Controller 6000 and Controller 7000 versions 8.80 and prior Controller 6000 and Controller 7000 versions 8.90 prior to vCR8.90.241107a Controller 6000 and Controller 7000 versions 9.00 prior to vCR9.00.241108a Controller 6000 and Controller...
CVE-2024-54485
CVE-2024-54485 affects Apple iOS/iPadOS where a user’s lock-screen notifications could be viewed by an attacker with physical access. The issue is mitigated by updates: iPadOS 17.7.3, iOS 18.2, and iPadOS 18.2 fix the flaw by adding additional logic to prevent lock-screen notification content exp...
CVE-2024-54485
The issue was addressed by adding additional logic. This issue is fixed in iOS 18.2 and iPadOS 18.2, iPadOS 17.7.3, macOS Sequoia 15.2. An attacker with physical access to an iOS device may be able to view notification content from the lock screen...
PT-2024-36352 · Apple · Ios +2
Name of the Vulnerable Software and Affected Versions: iPadOS versions prior to 17.7.3 iOS versions prior to 18.2 iPadOS versions prior to 18.2 Description: The issue allows an attacker with physical access to an iOS device to view notification content from the lock screen. This is possible due t...
CVE-2024-53832
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V05.30. The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the...
CVE-2024-53832
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V05.30. The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the...
CVE-2024-53832
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V05.30. The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the...
CVE-2024-53832
CVE-2024-53832 affects Siemens SICAM A8000 devices (CP-8031/CP-8050) with CPCI85 Central Processing/Communication, all versions before V05.30. A secure element is connected via an unencrypted SPI bus, enabling a physically proximate attacker to observe the authentication password and use the secu...
Schneider Electric Modicon
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
CVE-2024-53919
An injection vulnerability in Barco ClickShare CX-30/20, C-5/10, and ClickShare Bar Pro and Core models, running firmware before 2.21.1, allows physically proximate attackers or local admins to the webUI to trigger OS-level command execution as root...
Schneider Electric Harmony HMI and Pro-Face HMI Products
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
Schneider Electric PowerChute Serial Shutdown
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
PT-2024-35944 · Unknown · Cpci85 Central Processing/Communication
Name of the Vulnerable Software and Affected Versions: CPCI85 Central Processing/Communication versions prior to V05.30 Description: A vulnerability has been identified in the CPCI85 Central Processing/Communication devices. The affected devices contain a secure element connected via an unencrypt...
Undermining Integrity Features of SEV-SNP with Memory Aliasing
AMD ID: AMD-SB-3015 Potential Impact: Loss of Integrity Severity: Medium Summary A team of researchers has reported to AMD that it may be possible to modify serial presence detect SPD metadata to make an attached memory module appear larger than it is, potentially allowing an attacker to overwrit...
Making sure your door access control system is secure: Top 5 things to check
Your door access control system aka a physical access control system or PACS, also referred to as RFID cards or ‘swipe’ cards often have a poor reputation for being vulnerable to cloning attacks. Here’s the thing: it’s generally possible to configure your system to be very resistant to card...
CVE-2024-47146
Ruijie Reyee OS versions 2.206.x up to but not including 2.320.x could allow an attacker to obtain the devices serial number if physically adjacent and sniffing the RAW WIFI signal...
CVE-2024-12094 Information Disclosure Vulnerability in Tinxy
This vulnerability exists in the Tinxy mobile app due to storage of logged-in user information in plaintext on the device database. An attacker with physical access to the rooted device could exploit this vulnerability by accessing its database leading to unauthorized access of user information...
CVE-2024-54127 Exposure of Wi-Fi Credentials in Plaintext in TP-Link Archer C50
This vulnerability exists in the TP-Link Archer C50 due to presence of terminal access on a serial interface without proper access control. An attacker with physical access could exploit this by accessing the UART shell on the vulnerable device. Successful exploitation of this vulnerability could...