Lucene search
+L

9369 matches found

Cvelist
Cvelist
added 2024/12/12 1:35 a.m.20 views

CVE-2024-41146

Use of Multiple Resources with Duplicate Identifier CWE-694 in the Controller 6000 and Controller 7000 Platforms could allow an attacker with physical access to HBUS communication cabling to perform a Denial-of-Service attack against HBUS connected devices, require a device reboot to resolve. Thi...

4.6CVSS0.00305EPSS
SaveExploits0References1
CVE
CVE
added 2024/12/12 1:35 a.m.50 views

CVE-2024-41146

The CVE-2024-41146 affects Gallagher Controller 6000 and Controller 7000 platforms. The root cause is use of multiple resources with duplicate identifiers (CWE-694) in HBUS communications, which could allow a local attacker with physical access to HBUS cabling to trigger a Denial-of-Service on HB...

4.6CVSS6.8AI score0.00305EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2024/12/12 12:00 a.m.9 views

PT-2024-29294 · Unknown · Controller 6000 +1

Name of the Vulnerable Software and Affected Versions: Controller 6000 and Controller 7000 versions 8.80 and prior Controller 6000 and Controller 7000 versions 8.90 prior to vCR8.90.241107a Controller 6000 and Controller 7000 versions 9.00 prior to vCR9.00.241108a Controller 6000 and Controller...

4.6CVSS6.9AI score0.00305EPSS
SaveExploits0References3
CVE
CVE
added 2024/12/11 10:59 p.m.65 views

CVE-2024-54485

CVE-2024-54485 affects Apple iOS/iPadOS where a user’s lock-screen notifications could be viewed by an attacker with physical access. The issue is mitigated by updates: iPadOS 17.7.3, iOS 18.2, and iPadOS 18.2 fix the flaw by adding additional logic to prevent lock-screen notification content exp...

5.5CVSS7AI score0.00285EPSS
SaveExploits0References4Affected Software2
Cvelist
Cvelist
added 2024/12/11 10:59 p.m.38 views

CVE-2024-54485

The issue was addressed by adding additional logic. This issue is fixed in iOS 18.2 and iPadOS 18.2, iPadOS 17.7.3, macOS Sequoia 15.2. An attacker with physical access to an iOS device may be able to view notification content from the lock screen...

0.00285EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2024/12/11 12:00 a.m.10 views

PT-2024-36352 · Apple · Ios +2

Name of the Vulnerable Software and Affected Versions: iPadOS versions prior to 17.7.3 iOS versions prior to 18.2 iPadOS versions prior to 18.2 Description: The issue allows an attacker with physical access to an iOS device to view notification content from the lock screen. This is possible due t...

5.5CVSS6.2AI score0.00285EPSS
SaveExploits0References8
NVD
NVD
added 2024/12/10 2:30 p.m.24 views

CVE-2024-53832

A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V05.30. The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the...

5.1CVSS0.00292EPSS
SaveExploits1References2
Vulnrichment
Vulnrichment
added 2024/12/10 1:54 p.m.9 views

CVE-2024-53832

A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V05.30. The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the...

5.1CVSS6.8AI score0.00292EPSS
SaveExploits1References1
Cvelist
Cvelist
added 2024/12/10 1:54 p.m.24 views

CVE-2024-53832

A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V05.30. The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the...

5.1CVSS0.00292EPSS
SaveExploits1References1
CVE
CVE
added 2024/12/10 1:54 p.m.69 views

CVE-2024-53832

CVE-2024-53832 affects Siemens SICAM A8000 devices (CP-8031/CP-8050) with CPCI85 Central Processing/Communication, all versions before V05.30. A secure element is connected via an unencrypted SPI bus, enabling a physically proximate attacker to observe the authentication password and use the secu...

5.1CVSS6.8AI score0.00292EPSS
SaveExploits1References2
ICS
ICS
added 2024/12/10 5:00 a.m.11 views

Schneider Electric Modicon

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

9.8CVSS6.5AI score0.00641EPSS
SaveExploits0References11
Cvelist
Cvelist
added 2024/12/10 12:00 a.m.47 views

CVE-2024-53919

An injection vulnerability in Barco ClickShare CX-30/20, C-5/10, and ClickShare Bar Pro and Core models, running firmware before 2.21.1, allows physically proximate attackers or local admins to the webUI to trigger OS-level command execution as root...

7.6CVSS0.00433EPSS
SaveExploits0References2
ICS
ICS
added 2024/12/10 12:00 a.m.17 views

Schneider Electric Harmony HMI and Pro-Face HMI Products

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

8.8CVSS7AI score0.00636EPSS
SaveExploits0References11
ICS
ICS
added 2024/12/10 12:00 a.m.20 views

Schneider Electric PowerChute Serial Shutdown

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

6.3CVSS6.8AI score0.00978EPSS
SaveExploits0References11
Positive Technologies
Positive Technologies
added 2024/12/10 12:00 a.m.16 views

PT-2024-35944 · Unknown · Cpci85 Central Processing/Communication

Name of the Vulnerable Software and Affected Versions: CPCI85 Central Processing/Communication versions prior to V05.30 Description: A vulnerability has been identified in the CPCI85 Central Processing/Communication devices. The affected devices contain a secure element connected via an unencrypt...

5.1CVSS6.7AI score0.00292EPSS
SaveExploits1References5
Amd
Amd
added 2024/12/10 12:00 a.m.39 views

Undermining Integrity Features of SEV-SNP with Memory Aliasing

AMD ID: AMD-SB-3015 Potential Impact: Loss of Integrity Severity: Medium Summary A team of researchers has reported to AMD that it may be possible to modify serial presence detect SPD metadata to make an attached memory module appear larger than it is, potentially allowing an attacker to overwrit...

5.3CVSS7AI score0.00222EPSS
SaveExploits0
Pen Test Partners Blog
Pen Test Partners Blog
added 2024/12/09 6:49 a.m.17 views

Making sure your door access control system is secure: Top 5 things to check

Your door access control system aka a physical access control system or PACS, also referred to as RFID cards or ‘swipe’ cards often have a poor reputation for being vulnerable to cloning attacks. Here’s the thing: it’s generally possible to configure your system to be very resistant to card...

7.3AI score
SaveExploits0
NVD
NVD
added 2024/12/06 7:15 p.m.39 views

CVE-2024-47146

Ruijie Reyee OS versions 2.206.x up to but not including 2.320.x could allow an attacker to obtain the devices serial number if physically adjacent and sniffing the RAW WIFI signal...

7.1CVSS0.00282EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/12/05 12:27 p.m.30 views

CVE-2024-12094 Information Disclosure Vulnerability in Tinxy

This vulnerability exists in the Tinxy mobile app due to storage of logged-in user information in plaintext on the device database. An attacker with physical access to the rooted device could exploit this vulnerability by accessing its database leading to unauthorized access of user information...

5.4CVSS0.00148EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/12/05 12:19 p.m.14 views

CVE-2024-54127 Exposure of Wi-Fi Credentials in Plaintext in TP-Link Archer C50

This vulnerability exists in the TP-Link Archer C50 due to presence of terminal access on a serial interface without proper access control. An attacker with physical access could exploit this by accessing the UART shell on the vulnerable device. Successful exploitation of this vulnerability could...

4.2CVSS6.5AI score0.00153EPSS
SaveExploits0References1
Rows per page
Query Builder