6219 matches found
CVE-2018-9070: Undefined Security Weakness
For the Lenovo Smart Assistant Android app versions earlier than 12.1.82, an attacker with physical access to the smart speaker can, by pressing a specific button sequence, enter factory test mode and enable a web service intended for testing the device. As with most test modes, this provides ext...
Lenovo Smart Assistant Factory Test Mode - US
Lenovo Security Advisory: LEN-22172 Potential Impact: Root access of the device Severity: Medium Scope of Impact: Lenovo Smart Assistant CVE Identifier: CVE-2018-9070 Summary Description: Lenovo Smart Assistant is an Amazon Alexa-enabled smart speaker developed by Lenovo. An attacker with physica...
Information disclosure
Information disclosure vulnerability in storage media in systems with Intel Optane memory module with Whole Disk Encryption may allow an attacker to recover data via physical access...
CVE-2018-3619
Information disclosure vulnerability in storage media in systems with Intel Optane memory module with Whole Disk Encryption may allow an attacker to recover data via physical access...
CVE-2018-3619
Information disclosure vulnerability in storage media in systems with Intel Optane memory module with Whole Disk Encryption may allow an attacker to recover data via physical access...
CVE-2018-3619
CVE-2018-3619 describes an information-disclosure vulnerability in storage media when using an Intel® Optane™ memory module with BitLocker-enabled Whole Disk Encryption. A small region on the non-Optane memory can remain unencrypted if BitLocker is enabled after configuring the Optane module, pot...
CVE-2018-1492
IBM Jazz Foundation products could allow a user with physical access to the system to log in as another user due to the server's failure to properly log out from the previous session. IBM X-Force ID: 140977...
CVE-2018-1492
IBM Jazz Foundation products could allow a user with physical access to the system to log in as another user due to the server's failure to properly log out from the previous session. IBM X-Force ID: 140977...
CVE-2018-1492
IBM Jazz Foundation products could allow a user with physical access to the system to log in as another user due to the server's failure to properly log out from the previous session. IBM X-Force ID: 140977...
PT-2018-12799
Name of the Vulnerable Software and Affected Versions IBM Jazz Foundation products affected versions not specified Description The issue arises from the server's failure to properly log out from the previous session, allowing a user with physical access to the system to log in as another user...
CVE-2018-3619: Exposure of Sensitive Information to an Unauthorized Actor
Information disclosure vulnerability in storage media in systems with Intel Optane memory module with Whole Disk Encryption may allow an attacker to recover data via physical access...
CVE-2018-1492: Session Fixation
IBM Jazz Foundation products could allow a user with physical access to the system to log in as another user due to the server's failure to properly log out from the previous session. IBM X-Force ID: 140977...
PT-2018-16098
Name of the Vulnerable Software and Affected Versions Intel Optane memory module affected versions not specified Description The issue is related to an information disclosure vulnerability in storage media. It affects systems with Intel Optane memory modules that have Whole Disk Encryption enable...
CVE-2018-8870
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...
Input validation
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An...
CVE-2018-8870
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...
Hardcoded credentials
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain...
CVE-2018-8868 Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit oth...
CVE-2018-8870
CVE-2018-8870 affects Medtronic MyCareLink Monitors (models 24950 and 24952). The vulnerability is a hard-coded operating system password, enabling a physically proximate attacker who can open the device and connect via a debug port to gain privileged OS access. The ICS-CERT advisory corroborates...
Medtronic MyCareLink Patient Monitor Hardcoding Vulnerability
MyCareLink Patient Monitor is a patient monitor product developed by Medtronic, Inc. A hard-coded vulnerability in the Medtronic MyCareLink Patient Monitor allows an attacker with physical access to remove the device's enclosure, connect to the debug port, and use a password to gain privileged...