CVE-2018-2967
The CVE-2018-2967 entry concerns Oracle Primavera Unifier (Core) and affects the Primavera Unifier software in versions 16.x, 17.x and 18.x. The connected Nessus entry corroborates that installations running on the remote web server with 16.x (before 16.2.15.0), 17.x (before 17.12.7.0), or 18.x (...
CVE-2018-10631
The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including the binary executables. If modified to bypass protection...
CVE-2018-10631 Medtronic N'Vision Clinician Programmer Protection Mechanism Failure
The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including the binary executables. If modified to bypass protection...
CVE-2018-9070
For the Lenovo Smart Assistant Android app versions earlier than 12.1.82, an attacker with physical access to the smart speaker can, by pressing a specific button sequence, enter factory test mode and enable a web service intended for testing the device. As with most test modes, this provides ext...
CVE-2018-9070
For the Lenovo Smart Assistant Android app versions earlier than 12.1.82, an attacker with physical access to the smart speaker can, by pressing a specific button sequence, enter factory test mode and enable a web service intended for testing the device. As with most test modes, this provides ext...
CVE-2018-9070
The CVE-2018-9070 flaw affects Lenovo Smart Assistant Android app versions
Lenovo Smart Assistant Factory Test Mode - US
Lenovo Security Advisory: LEN-22172 Potential Impact: Root access of the device Severity: Medium Scope of Impact: Lenovo Smart Assistant CVE Identifier: CVE-2018-9070 Summary Description: Lenovo Smart Assistant is an Amazon Alexa-enabled smart speaker developed by Lenovo. An attacker with physica...
CVE-2018-3619
Information disclosure vulnerability in storage media in systems with Intel Optane memory module with Whole Disk Encryption may allow an attacker to recover data via physical access...
Information disclosure
Information disclosure vulnerability in storage media in systems with Intel Optane memory module with Whole Disk Encryption may allow an attacker to recover data via physical access...
CVE-2018-3619
CVE-2018-3619 describes an information-disclosure vulnerability in storage media when using an Intel® Optane™ memory module with BitLocker-enabled Whole Disk Encryption. A small region on the non-Optane memory can remain unencrypted if BitLocker is enabled after configuring the Optane module, pot...
CVE-2018-3619
Information disclosure vulnerability in storage media in systems with Intel Optane memory module with Whole Disk Encryption may allow an attacker to recover data via physical access...
CVE-2018-1492
IBM Jazz Foundation products could allow a user with physical access to the system to log in as another user due to the server's failure to properly log out from the previous session. IBM X-Force ID: 140977...
CVE-2018-1492
IBM Jazz Foundation products could allow a user with physical access to the system to log in as another user due to the server's failure to properly log out from the previous session. IBM X-Force ID: 140977...
CVE-2018-1492
IBM Jazz Foundation products could allow a user with physical access to the system to log in as another user due to the server's failure to properly log out from the previous session. IBM X-Force ID: 140977...
CVE-2018-8870
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...
Input validation
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An...
Hardcoded credentials
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain...
CVE-2018-8870
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system...
CVE-2018-8870
CVE-2018-8870 affects Medtronic MyCareLink Monitors (models 24950 and 24952). The vulnerability is a hard-coded operating system password, enabling a physically proximate attacker who can open the device and connect via a debug port to gain privileged OS access. The ICS-CERT advisory corroborates...
CVE-2018-8868 Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit oth...