5073 matches found
CVE-2019-18254
BIOTRONIK CardioMessenger II, The affected products do not encrypt sensitive information while at rest. An attacker with physical access to the CardioMessenger can disclose medical measurement data and the serial number from the implanted cardiac device the CardioMessenger is paired with...
CVE-2019-18256
BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit...
CVE-2019-18254
BIOTRONIK CardioMessenger II, The affected products do not encrypt sensitive information while at rest. An attacker with physical access to the CardioMessenger can disclose medical measurement data and the serial number from the implanted cardiac device the CardioMessenger is paired with...
CVE-2020-12024
Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to th...
Baxter PrismaFlex and PrisMax (Update B)
1. EXECUTIVE SUMMARY CVSS v3 7.6 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Baxter Equipment: PrismaFlex and PrisMax Vulnerabilities: Cleartext Transmission of Sensitive Information, Improper Authentication, Use of Hard-Coded Password 2. UPDATE INFORMATION This updated...
BIOTRONIK CardioMessenger II
1. EXECUTIVE SUMMARY CVSS v3 4.6 ATTENTION: Exploitable with adjacent access/low skill level to exploit Vendor: BIOTRONIK Equipment: CardioMessenger II-S T-Line, CardioMessenger II-S GSM Vulnerabilities: Improper Authentication, Cleartext Transmission of Sensitive Information, Missing Encryption...
Security lock can be bypassed by changing the system date
Given an attacker has physical access to the device, a faulty timestamp check allowed to bypass the app lock by setting the system date to the past...
CVE-2020-8675
Insufficient control flow management in firmware build and signing tool for IntelR Innovation Engine before version 1.0.859 may allow an unauthenticated user to potentially enable escalation of privilege via physical access...
CVE-2020-8675
Insufficient control flow management in firmware build and signing tool for IntelR Innovation Engine before version 1.0.859 may allow an unauthenticated user to potentially enable escalation of privilege via physical access...
CVE-2020-0566
Improper Access Control in subsystem for IntelR TXE versions before 3.175 and 4.0.25 may allow an unauthenticated user to potentially enable escalation of privilege via physical access...
CVE-2020-0566
Improper Access Control in subsystem for IntelR TXE versions before 3.175 and 4.0.25 may allow an unauthenticated user to potentially enable escalation of privilege via physical access...
Design/Logic Flaw
Insufficient control flow management in firmware build and signing tool for IntelR Innovation Engine before version 1.0.859 may allow an unauthenticated user to potentially enable escalation of privilege via physical access...
Improper access control
Improper Access Control in subsystem for IntelR TXE versions before 3.175 and 4.0.25 may allow an unauthenticated user to potentially enable escalation of privilege via physical access...
CVE-2020-0566
Improper Access Control in subsystem for IntelR TXE versions before 3.175 and 4.0.25 may allow an unauthenticated user to potentially enable escalation of privilege via physical access...
CVE-2020-0566
CVE-2020-0566 concerns Intel TXE (Trusted Execution Engine) with improper access control in the subsystem. The provided documents identify affected TXE versions prior to 3.175 and 4.0.25, enabling an unauthenticated user to potentially escalate privileges via physical access. The Intel INTEL-SA-0...
CVE-2020-8675
Insufficient control flow management in firmware build and signing tool for IntelR Innovation Engine before version 1.0.859 may allow an unauthenticated user to potentially enable escalation of privilege via physical access...
CVE-2020-5363
Select Dell Client Consumer and Commercial platforms include an issue that allows the BIOS Admin password to be changed through Dell's manageability interface without knowledge of the current BIOS Admin password. This could potentially allow an unauthorized actor, with physical access and/or OS...
CVE-2020-5363
Select Dell Client Consumer and Commercial platforms include an issue that allows the BIOS Admin password to be changed through Dell's manageability interface without knowledge of the current BIOS Admin password. This could potentially allow an unauthorized actor, with physical access and/or OS...
CVE-2020-13238
Mitsubishi MELSEC iQ-R Series PLCs with firmware 33 allow attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, because this denial of service attack consumes excessive CPU time. After halting, physical access to the PLC is required in order to...
CVE-2020-13238
Mitsubishi MELSEC iQ-R Series PLCs with firmware 33 allow attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, because this denial of service attack consumes excessive CPU time. After halting, physical access to the PLC is required in order to...