added 2025/07/30 12:15 a.m.10 views

CVE-2025-43259

This issue was addressed with improved redaction of sensitive information. This issue is fixed in macOS Sequoia 15.6, macOS Sonoma 14.7.7, macOS Ventura 13.7.7. An attacker with physical access to a locked device may be able to view sensitive user information...

4.6CVSS0.00289EPSS
SaveExploits0References6
CVE
CVE
added 2025/07/29 11:35 p.m.41 views

CVE-2025-43259

CVE-2025-43259 is a macOS vulnerability where an attacker with physical access to a locked device may view sensitive user information. The issue is fixed in macOS Sequoia 15.6, macOS Sonoma 14.7.7, and macOS Ventura 13.7.7. The vulnerability affects the confidentiality of data on affected systems...

4.6CVSS5.2AI score0.00289EPSS
SaveExploits0References6Affected Software1
Cvelist
Cvelist
added 2025/07/29 11:35 p.m.16 views

CVE-2025-43259

This issue was addressed with improved redaction of sensitive information. This issue is fixed in macOS Sequoia 15.6, macOS Sonoma 14.7.7, macOS Ventura 13.7.7. An attacker with physical access to a locked device may be able to view sensitive user information...

0.00289EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
added 2025/07/29 11:35 p.m.4 views

CVE-2025-43259

This issue was addressed with improved redaction of sensitive information. This issue is fixed in macOS Sequoia 15.6, macOS Sonoma 14.7.7, macOS Ventura 13.7.7. An attacker with physical access to a locked device may be able to view sensitive user information...

5.5AI score0.00289EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2025/07/29 12:00 a.m.6 views

PT-2025-31331 · Apple · Apple Macos

Name of the Vulnerable Software and Affected Versions: macOS versions prior to 15.6 macOS versions prior to 14.7.7 macOS versions prior to 13.7.7 Description: The issue involves improved redaction of sensitive information. An attacker with physical access to a locked device may be able to view...

4.6CVSS6.1AI score0.00289EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
added 2025/07/28 12:00 a.m.14 views

PT-2025-31105 · Unknown · Marbella Kr8S Dashcam

Name of the Vulnerable Software and Affected Versions: Marbella KR8s Dashcam FF version 2.0.8 Description: An issue exists where the existing password is written in cleartext onto a newly inserted SD card. An attacker with temporary physical access to the device can steal the password by swapping...

9.8CVSS6.4AI score0.00286EPSS
SaveExploits0References7
Cvelist
Cvelist
added 2025/07/24 3:30 a.m.22 views

CVE-2025-4395 Medtronic MyCareLink Patient Monitor Empty Password Vulnerability

Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS0.0027EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2025/07/24 3:30 a.m.6 views

CVE-2025-4395 Medtronic MyCareLink Patient Monitor Empty Password Vulnerability

Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS6.4AI score0.0027EPSS
SaveExploits0References2
CVE
CVE
added 2025/07/24 3:26 a.m.32 views

CVE-2025-4394

CVE-2025-4394 affects Medtronic MyCareLink Patient Monitor models 24950 and 24952. The root cause is an unencrypted filesystem on internal storage that allows a physical attacker with access to read and modify files. The CVSS 3.1 vector (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) yields a base score of...

6.8CVSS6AI score0.00188EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2025/07/24 3:26 a.m.8 views

CVE-2025-4394 Medtronic MyCareLink Patient Monitor Unencrypted Filesystem Vulnerability

Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS6.2AI score0.00188EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2025/07/24 3:26 a.m.33 views

CVE-2025-4394 Medtronic MyCareLink Patient Monitor Unencrypted Filesystem Vulnerability

Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS0.00188EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2025/07/24 3:26 a.m.7 views

CVE-2025-4394

Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS5.9AI score0.00188EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2025/07/24 12:00 a.m.16 views

PT-2025-30629 · Medtronic · Mycarelink Patient Monitor

Name of the Vulnerable Software and Affected Versions: Medtronic MyCareLink Patient Monitor versions 24950 and 24952 before June 25, 2025 Description: The Medtronic MyCareLink Patient Monitor utilizes an unencrypted filesystem on its internal storage. This allows an attacker with physical access ...

6.8CVSS5.8AI score0.00188EPSS
SaveExploits0References6
CNNVD
CNNVD
added 2025/07/24 12:00 a.m.10 views

Medtronic MyCareLink Patient Monitor 安全漏洞

Medtronic MyCareLink Patient Monitor is an open source monitoring system for remote patient monitoring from Medtronic in the United States. A security vulnerability exists in Medtronic MyCareLink Patient Monitor versions prior to 2025.6.25, which stems from the use of an empty password for the...

6.8CVSS6.8AI score0.0027EPSS
SaveExploits0References1
ICS
ICS
added 2025/07/21 12:30 a.m.22 views

ABB Busch-Welcome 2 Wire Door Opener Actuator

SUMMARY ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could gain physical, unauthorized access to a Building where the product is installed 2. MITIGATING FACTORS ABB recommends double check...

8.6CVSS5.8AI score0.00193EPSS
SaveExploits0References11
Cvelist
Cvelist
added 2025/07/18 10:51 p.m.29 views

CVE-2025-7396 Curve25519 Blinding

In wolfSSL release 5.8.2 blinding support is turned on by default for Curve25519 in applicable builds. The blinding configure option is only for the base C implementation of Curve25519. It is not needed, or available with; ARM assembly builds, Intel assembly builds, and the small Curve25519...

5.6CVSS0.00192EPSS
SaveExploits0References1
Debian CVE
Debian CVE
added 2025/07/18 10:51 p.m.19 views

CVE-2025-7396

In wolfSSL release 5.8.2 blinding support is turned on by default for Curve25519 in applicable builds. The blinding configure option is only for the base C implementation of Curve25519. It is not needed, or available with; ARM assembly builds, Intel assembly builds, and the small Curve25519...

5.6CVSS5.3AI score0.00192EPSS
SaveExploits0
Positive Technologies
Positive Technologies
added 2025/07/18 12:00 a.m.18 views

PT-2025-30103

Name of the Vulnerable Software and Affected Versions wolfSSL version 5.8.2 Description In wolfSSL release 5.8.2, blinding support is enabled by default for Curve25519 in applicable builds. This feature provides an additional layer of protection against side-channel attacks aimed at extracting a...

5.6CVSS6.1AI score0.00192EPSS
SaveExploits0References13
Vulnrichment
Vulnrichment
added 2025/07/16 11:18 a.m.3 views

CVE-2025-53755 Cleartext Storage Vulnerability in Digisol DG-GR6821AC Router

This vulnerability exists in Digisol DG-GR6821AC Router due to storage of credentials and PINS without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted dat...

5.1CVSS6.3AI score0.00091EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2025/07/16 11:18 a.m.19 views

CVE-2025-53755 Cleartext Storage Vulnerability in Digisol DG-GR6821AC Router

This vulnerability exists in Digisol DG-GR6821AC Router due to storage of credentials and PINS without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted dat...

5.1CVSS0.00091EPSS
SaveExploits0References1
Rows per page
Query Builder