added 2025/02/11 6:0 a.m.9 views

Schneider Electric Enerlin’X IFE and eIFE

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

7AI score
SaveExploits0References11
Tenable Nessus
Tenable Nessus
added 2025/01/23 12:0 a.m.9 views

Sprecher Automation SPRECON-E-C/P/T3 Improper Input Validation (CVE-2022-4332)

In Sprecher Automation SPRECON-E-C/P/T3 CPU in variant PU244x a vulnerable firmware verification has been identified. Through physical access and hardware manipulation, an attacker might be able to bypass hardware-based code verification and thus inject and execute arbitrary code and gain full...

6.8CVSS6.7AI score0.00335EPSS
SaveExploits1References2
Packet Storm
Packet Storm
added 2025/01/12 12:0 a.m.131 views

CISA: Strategies for Effectively Blending Cyber and Physical Security within Critical Infrastructure

System About Files News Vote Help | Services API Advertise Contact | Account Join Login ---|---|---...

7.4AI score
SaveExploits0
Packet Storm
Packet Storm
added 2025/01/12 12:0 a.m.115 views

CISA: Cybersecurity for Physical Security Professionals

System About Files News Vote Help | Services API Advertise Contact | Account Join Login ---|---|---...

7.4AI score
SaveExploits0
Packet Storm
Packet Storm
added 2025/01/12 12:0 a.m.129 views

CISA: Cyber and Physical Security in Manufacturing Environments

System About Files News Vote Help | Services API Advertise Contact | Account Join Login ---|---|---...

7.4AI score
SaveExploits0
Packet Storm
Packet Storm
added 2025/01/12 12:0 a.m.127 views

CISA: Chemical Facility Anti-Terrorism Standards (CFATS) Cyber and Physical Security Best Practices

System About Files News Vote Help | Services API Advertise Contact | Account Join Login ---|---|---...

7.4AI score
SaveExploits0
ICS
ICS
added 2024/11/12 5:0 a.m.16 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E (Update B)

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

6.5AI score
SaveExploits0References11
ICS
ICS
added 2024/10/08 4:0 a.m.11 views

Schneider Electric EcoStruxure Power Monitoring Expert (PME) (Update B)

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

7.3CVSS6.9AI score0.00342EPSS
SaveExploits0References11
ICS
ICS
added 2024/10/08 12:0 a.m.12 views

Schneider Electric Easergy Studio

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

7.8CVSS7.1AI score0.00172EPSS
SaveExploits0References11
Wiz blog
Wiz blog
added 2024/07/30 7:34 p.m.6 views

Physical Security 101

Protecting your assets: the fundamentals of physical security and enterprise resilience at Wiz...

7.1AI score
SaveExploits0
NVD
NVD
added 2024/07/11 3:15 a.m.21 views

CVE-2024-22387

External Control of Critical State Data CWE-642 in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated user to modify device I/O connections leading to unexpected behavior that in some circumstances could compromise site physical security controls. Gallagher...

6.8CVSS0.00306EPSS
SaveExploits0References1
CVE
CVE
added 2024/07/11 2:38 a.m.49 views

CVE-2024-22387

CVE-2024-22387 affects Gallagher Controller 6000 and 7000 via the diagnostic web interface. An authenticated user can externally control critical state data to modify device I/O connections, causing unexpected behavior and potentially compromising site physical security controls. Affected version...

6.8CVSS6.4AI score0.00306EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/07/11 2:38 a.m.32 views

CVE-2024-22387

External Control of Critical State Data CWE-642 in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated user to modify device I/O connections leading to unexpected behavior that in some circumstances could compromise site physical security controls. Gallagher...

6.8CVSS0.00306EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/07/11 2:38 a.m.10 views

CVE-2024-22387

External Control of Critical State Data CWE-642 in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated user to modify device I/O connections leading to unexpected behavior that in some circumstances could compromise site physical security controls. Gallagher...

6.8CVSS6.4AI score0.00306EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2024/07/11 12:0 a.m.5 views

Gallagher Controller 6000 and Gallagher Controller 7000 Security Vulnerabilities

The Gallagher Controller 6000 and Gallagher Controller 7000 are both products of Gallagher New Zealand.The Gallagher Controller 6000 is an interface between a Gallagher Command Center server and distributed field hardware. The Gallagher Controller 7000 is a powerful network connected controller. ...

6.8CVSS6.4AI score0.00306EPSS
SaveExploits0References2
ICS
ICS
added 2024/07/09 12:0 a.m.18 views

Schneider Electric FoxRTU Station

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

7.8CVSS7.5AI score0.00281EPSS
SaveExploits0References11
ICS
ICS
added 2024/05/30 6:0 a.m.18 views

Baxter Welch Allyn Configuration Tool

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.4 ATTENTION : Exploitable remotely Vendor : Baxter Equipment : Welch Allyn Configuration Tool Vulnerability : Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to the unintended exposure of...

9.4CVSS6.6AI score0.00477EPSS
SaveExploits0References10
NVD
NVD
added 2024/02/19 10:15 p.m.23 views

CVE-2023-6260

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Brivo ACS100, ACS300 allows OS Command Injection, Bypassing Physical Security.This issue affects ACS100 Network Adjacent Access, ACS300 Physical Access: from 5.2.4 before 6.2.4.3...

9CVSS9.3AI score0.00902EPSS
SaveExploits0References2
NVD
NVD
added 2024/02/19 10:15 p.m.23 views

CVE-2023-6259

Insufficiently Protected Credentials, : Improper Access Control vulnerability in Brivo ACS100, ACS300 allows Password Recovery Exploitation, Bypassing Physical Security.This issue affects ACS100, ACS300: from 5.2.4 before 6.2.4.3...

7.1CVSS6.9AI score0.00235EPSS
SaveExploits0References2
OSV
OSV
added 2024/02/19 10:15 p.m.6 views

CVE-2023-6260

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Brivo ACS100, ACS300 allows OS Command Injection, Bypassing Physical Security.This issue affects ACS100 Network Adjacent Access, ACS300 Physical Access: from 5.2.4 before 6.2.4.3...

8.8CVSS5.8AI score0.00902EPSS
SaveExploits0References2