1750 matches found
CVE-2020-12521
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot...
CVE-2020-12523
On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device configuration. For mGuard devices with integrated switch on the LAN side, single switch ports can be disabled by device configuration. After a reboot these ports g...
CVE-2020-12519
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell with root privileges...
CVE-2020-12519
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell with root privileges...
CVE-2020-12521
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot...
CVE-2020-12518
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks...
CVE-2020-12518
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks...
CVE-2020-12517
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an authenticated low privileged user could embed malicious Javascript code to gain admin rights when the admin user visits the vulnerable website local privilege escalation...
Design/Logic Flaw
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot...
Open redirect
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell with root privileges...
Design/Logic Flaw
On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device configuration. For mGuard devices with integrated switch on the LAN side, single switch ports can be disabled by device configuration. After a reboot these ports g...
Privilege escalation
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an authenticated low privileged user could embed malicious Javascript code to gain admin rights when the admin user visits the vulnerable website local privilege escalation...
Information disclosure
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks...
CVE-2020-12521 Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: A specially crafted LLDP packet may lead to a high system load in the PROFINET stack.
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot...
CVE-2020-12517
Summary: Phoenix Contact PLCnext Control Devices (prior to 2021.0 LTS) are affected by a cross-site scripting vulnerability. An authenticated, low-privileged user can embed malicious JavaScript that executes when an administrator visits the vulnerable web interface, leading to local privilege esc...
CVE-2020-12518 Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks...
CVE-2020-12518
CVE-2020-12518 affects Phoenix Contact PLCnext Control Devices released before 2021.0 LTS. The vulnerability is an information disclosure flaw where an attacker can read insufficiently protected sensitive information to plan further attacks. The CVSS metrics indicate partial confidentiality impac...
CVE-2020-12523 Phoenix Contact mGuard Devices versions before 8.8.3: LAN ports get functional after reboot even if they are disabled in the device configuration
On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device configuration. For mGuard devices with integrated switch on the LAN side, single switch ports can be disabled by device configuration. After a reboot these ports g...
CVE-2020-12521
CVE-2020-12521 concerns Phoenix Contact PLCnext Control Devices (pre-2021.0 LTS). A specially crafted LLDP packet can cause a high load in the PROFINET stack, potentially leading to system service failures or a complete reboot. The vulnerability is described across multiple sources as an input va...
CVE-2020-12519
CVE-2020-12519 affects Phoenix Contact PLCnext Control Devices prior to 2021.0 LTS. The vulnerability allows an attacker to open a reverse shell with root privileges. The provided sources confirm this impact but do not specify the root-cause details or a patched version within the connected docum...