Lucene search
+L

1051 matches found

CVE
CVE
•added 2018/09/26 7:00 p.m.•67 views

CVE-2018-8848

Philips e-Alert Unit (non-medical device), Version R2.1 and prior, is affected by CVE-2018-8848 due to incorrect default permissions that expose an object to an unintended actor. This CVE is categorized under CWE-276 (Incorrect Default Permissions). The issue was observed during installation and ...

7.5CVSS7.4AI score0.02026EPSS
SaveExploits0References3Affected Software1
CVE
CVE
•added 2018/09/26 7:00 p.m.•60 views

CVE-2018-8852

Philips e-Alert Unit (non-medical device), Version R2.1 and prior, is affected by CVE-2018-8852 (session fixation). When authenticating or establishing a new session, an attacker may steal authenticated sessions without invalidating existing session IDs, enabling session hijacking. Severity in CV...

8.8CVSS8.3AI score0.01897EPSS
SaveExploits0References3Affected Software1
CVE
CVE
•added 2018/09/26 7:00 p.m.•63 views

CVE-2018-8856

This CVE affects Philips e-Alert Unit (non-medical device), Versions R2.1 and prior. The issue is the use of a hard-coded cryptographic key for internal data encryption (CWE-798), which enables high-severity impact. Per the connected docs, CVSS v3 base score is 9.8 (critical) with remote/network ...

9.8CVSS9.3AI score0.01378EPSS
SaveExploits0References3Affected Software1
CVE
CVE
•added 2018/09/26 7:00 p.m.•64 views

CVE-2018-8854

CVE-2018-8854 affects Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The issue is Uncontrolled Resource Consumption (Resource Exhaustion): the software does not properly restrict the size/amount of resources requested, allowing an attacker to consume resources. Affects Philips...

7.5CVSS7.3AI score0.02523EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
•added 2018/09/26 7:00 p.m.•34 views

CVE-2018-8844

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request...

8.6AI score0.00873EPSS
SaveExploits0References3
CVE
CVE
•added 2018/09/26 7:00 p.m.•61 views

CVE-2018-8850

Philips e-Alert Unit (non‑medical) Version R2.1 and prior is affected by CVE-2018-8850 due to improper input validation (CWE-20), which can cause unintended input, altered control flow, or arbitrary code execution. The vulnerability is documented with high to critical impact (NVD CVSS v3 base 9.8...

9.8CVSS9.4AI score0.03834EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
•added 2018/09/26 7:00 p.m.•33 views

CVE-2018-8854

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended...

7.4AI score0.02523EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2018/09/26 7:00 p.m.•37 views

CVE-2018-8842

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to...

8.2AI score0.0057EPSS
SaveExploits0References3
CVE
CVE
•added 2018/09/26 7:00 p.m.•72 views

CVE-2018-14803

Philips e-Alert Unit (non-medical device), Version R2.1 and prior, is affected by CVE-2018-14803 which describes an information-disclosure vulnerability: an attacker could obtain extraneous product information (e.g., OS/software components) via HTTP response headers that are normally not exposed....

5.3CVSS4.8AI score0.01738EPSS
SaveExploits0References3Affected Software1
CVE
CVE
•added 2018/09/26 7:00 p.m.•60 views

CVE-2018-8846

Philips e-Alert Unit (non-medical device), Version R2.1 and prior, contains an input handling flaw that allows cross-site scripting when user-controlled data is placed in web page output. This CVE (CVE-2018-8846) is documented with a CWE-79 XSS pattern and a CVSS v3 base score of 7.1 (AV:N/AC:L/P...

6.1CVSS5.8AI score0.01259EPSS
SaveExploits0References3Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/09/26 12:00 a.m.•7 views

CVE-2018-8848: Incorrect Default Permissions

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...

7.5CVSS7.6AI score0.02026EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/09/26 12:00 a.m.•6 views

CVE-2018-8846: Improper Neutralization of Input During Web Page Generation

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users...

6.1CVSS6.9AI score0.01259EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/09/26 12:00 a.m.•6 views

CVE-2018-8856: Use of Hard-coded Credentials

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data...

9.8CVSS8.3AI score0.01378EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/09/26 12:00 a.m.•5 views

CVE-2018-8844: Cross-Site Request Forgery (CSRF)

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request...

8.8CVSS7.8AI score0.00873EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/09/26 12:00 a.m.•6 views

CVE-2018-8852: Session Fixation

Philips e-Alert Unit non-medical device, Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier...

8.8CVSS7.8AI score0.01897EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/09/26 12:00 a.m.•6 views

CVE-2018-8850: Improper Input Validation

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result ...

9.8CVSS8.6AI score0.03834EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2018/09/26 12:00 a.m.•3 views

PT-2018-18655

Name of the Vulnerable Software and Affected Versions Philips e-Alert Unit non-medical device versions R2.1 and prior Description The software transmits sensitive data in cleartext over a communication channel, which can be intercepted by unauthorized actors. This lack of encryption could lead to...

8.8CVSS0.0057EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2018/09/26 12:00 a.m.•2 views

PT-2018-18657

Name of the Vulnerable Software and Affected Versions Philips e-Alert Unit non-medical device versions R2.1 and prior Description The web application of the Philips e-Alert Unit does not sufficiently verify whether a request was intentionally provided by the user who submitted it, which can lead ...

8.8CVSS0.00873EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2018/09/26 12:00 a.m.•2 views

PT-2018-18659

Name of the Vulnerable Software and Affected Versions Philips e-Alert Unit non-medical device versions R2.1 and prior Description The software does not properly neutralize user-controllable input before it is placed in output that is used as a web page, which is then served to other users...

6.1CVSS0.01259EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2018/09/26 12:00 a.m.•4 views

PT-2018-18661

Name of the Vulnerable Software and Affected Versions Philips e-Alert Unit non-medical device versions R2.1 and prior Description The software sets incorrect permissions for an object upon installation, exposing it to an unintended actor. Recommendations For Philips e-Alert Unit non-medical devic...

7.5CVSS0.02026EPSS
SaveExploits0References5
Rows per page