CVE-2019-10988: Use of Obsolete Function

In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploit...

3.6CVSS5.5AI score0.00344EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2019/09/04 12:00 a.m.•2 views

PT-2019-12123

Name of the Vulnerable Software and Affected Versions Philips HDI 4000 Ultrasound Systems affected versions not specified Description The issue concerns Philips HDI 4000 Ultrasound Systems running on outdated, unsupported operating systems like Windows 2000. Since the underlying operating system ...

3.6CVSS0.00344EPSS
SaveExploits0References2
CNVD
CNVD
•added 2019/09/02 12:00 a.m.•14 views

Unspecified Vulnerability in Philips HDI 4000 Ultrasound Systems

Philips HDI 4000 Ultrasound Systems is a set of ultrasound equipment for the medical industry from the European company Philips. A security vulnerability exists in the Philips HDI 4000 Ultrasound Systems running on older operating systems that are no longer supported, such as Windows 2000. An...

3.6CVSS6.6AI score0.00344EPSS
SaveExploits0References1
ICS
ICS
•added 2019/08/29 12:00 a.m.•82 views

Philips HDI 4000 Ultrasound

1. EXECUTIVE SUMMARY CVSS v3 3.0 ATTENTION: Public exploits are available/exploitable from within the same local subnet Vendor: Philips Equipment: HDI 4000 Ultrasound Systems Vulnerability: Use of Obsolete Function 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to...

3.6CVSS4.1AI score0.00344EPSS
SaveExploits0References5
NVD
NVD
•added 2019/07/24 3:15 p.m.•30 views

CVE-2019-10968

Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled...

4.4CVSS4.7AI score0.00335EPSS
SaveExploits0References1
Prion
Prion
•added 2019/07/24 3:15 p.m.•26 views

Code injection

Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled...

2.1CVSS4.7AI score0.00335EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/07/24 2:46 p.m.•33 views

CVE-2019-10968

Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled...

4.8AI score0.00335EPSS
SaveExploits0References1
CVE
CVE
•added 2019/07/24 2:46 p.m.•155 views

CVE-2019-10968

The CVE-2019-10968 vulnerability affects Philips Holter 2010 Plus (all versions). It concerns use of an obsolete function (CWE-477) that may allow enabling system options that were not purchased. The risk is described as local, with no remote exploitation and required high skill; impact is the po...

4.4CVSS4.8AI score0.00335EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/07/24 12:00 a.m.•5 views

CVE-2019-10968: Use of Obsolete Function

Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled...

4.4CVSS5.7AI score0.00335EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2019/07/24 12:00 a.m.•3 views

PT-2019-12109

Name of the Vulnerable Software and Affected Versions Philips Holter 2010 Plus, all versions. Description A vulnerability has been identified that may allow system options that were not purchased to be enabled. Recommendations For Philips Holter 2010 Plus, all versions: At the moment, there is no...

4.4CVSS0.00335EPSS
SaveExploits0References2
CNVD
CNVD
•added 2019/07/15 12:00 a.m.•15 views

Philips Holter 2010 Plus Access Control Error Vulnerability

Philips Holter 2010 Plus is a suite of ambulatory ECG monitoring software from Philips Europe. A security bypass vulnerability exists in Philips Holter 2010 Plus all versions. A local attacker can exploit this vulnerability to bypass security restrictions and gain unauthorized access to disabled...

4.4CVSS6.7AI score0.00335EPSS
SaveExploits0References1
ICS
ICS
•added 2019/07/11 12:00 a.m.•42 views

Philips Holter 2010 Plus

1. EXECUTIVE SUMMARY CVSS v3 1.9 Vendor : Philips Equipment : Philips Holter 2010 Vulnerability : Use of Obsolete Function 2. RISK EVALUATION Successful exploitation of this vulnerability under certain conditions can lead to a product feature escalation. 3. TECHNICAL DETAILS 3.1 AFFECTED...

4.4CVSS4.7AI score0.00335EPSS
SaveExploits0References5
OSV
OSV
•added 2019/05/01 7:29 p.m.•17 views

CVE-2019-6562

In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users...

5.4CVSS6.1AI score0.00671EPSS
SaveExploits0References1
Prion
Prion
•added 2019/05/01 7:29 p.m.•25 views

Design/Logic Flaw

In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users...

3.5CVSS5.4AI score0.00671EPSS
SaveExploits0References1Affected Software1
NVD
NVD
•added 2019/05/01 7:29 p.m.•29 views

CVE-2019-6562

In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users...

5.4CVSS5.4AI score0.00671EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/05/01 6:23 p.m.•35 views

CVE-2019-6562

In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users...

5.5AI score0.00671EPSS
SaveExploits0References1
CVE
CVE
•added 2019/05/01 6:23 p.m.•76 views

CVE-2019-6562

CVE-2019-6562 affects Philips Tasy EMR (versions 3.02.1744 and prior) and related WebPortal components. The root cause is improper neutralization of input during web page generation (XSS) , leading to potential cross-site scripting. Affected: Tasy EMR 3.02.1744 and prior; Tasy WebPortal 3.02.1757...

5.4CVSS5.4AI score0.00671EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/05/01 12:00 a.m.•5 views

CVE-2019-6562: Improper Neutralization of Input During Web Page Generation

In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users...

5.4CVSS5.8AI score0.00671EPSS
SaveExploits0References3
Symantec
Symantec
•added 2019/04/30 12:00 a.m.•56 views

Philips Tasy EMR CVE-2019-6562 Cross Site Scripting Vulnerability

Description Philips Tasy EMR is prone to a cross-site scripting vulnerability because it fails to properly sanitize user-supplied input. An attacker may leverage this issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow...

3.5CVSS0.1AI score0.00671EPSS
SaveExploits0References1Affected Software2
ICS
ICS
•added 2019/04/30 12:00 a.m.•105 views

Philips Tasy EMR (Update A)

1. EXECUTIVE SUMMARY --------- Begin Update A Part 1 of 7 --------- CVSS v3 4.3 ATTENTION: Low skill level to exploit --------- End Update A Part 1 of 7 --------- Vendor: Philips Equipment: Tasy EMR --------- Begin Update A Part 2 of 7 --------- Vulnerability: Cross-site Scripting, Information...

5.4CVSS6.2AI score0.00671EPSS
SaveExploits0References5