Lucene search
K

58 matches found

CVE
CVE
added 2022/02/12 2:30 a.m.92 views

CVE-2022-22765

BD Viper LT system (BD) is affected for all versions 2.0 and later due to use of hard-coded credentials (CWE-798). The ICS advisory icsma-22-062-02 documents that an attacker could access, modify, or delete ePHI, PHI, and PII. The 4.0+ Windows 10 hardening in newer releases raises attack complexi...

8CVSS7.6AI score0.00054EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2022/02/12 2:30 a.m.24 views

CVE-2022-22765 BD Viper LT System - Hardcoded Credentials

BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and personally identifiable information...

8CVSS7.8AI score0.00054EPSS
Exploits0References2
Microsoft Secure
Microsoft Secure
added 2021/02/04 7:0 p.m.145 views

Automating and operationalizing data protection with Dataguise and Microsoft Information Protection

This blog post is part of the Microsoft Intelligent Security Association guest blog series. Learn more about MISA. In technical literature, the terms data discovery, classification, and tagging are sometimes used interchangeably, but there are real differences in what they actually mean—and each...

0.2AI score
Exploits0
ThreatPost
ThreatPost
added 2020/12/08 5:0 p.m.43 views

Critical, Unpatched Bug Opens GE Radiological Devices to Remote Code Execution

A pair of critical vulnerabilities have been discovered in dozens of GE Healthcare radiological devices popular in hospitals, which could allow an attacker to gain access to sensitive personal health information PHI, alter data and even shut the machine’s availability down. The flaws affect 100...

0.1AI score0.00235EPSS
Exploits0References9
Prion
Prion
added 2020/12/03 4:15 p.m.14 views

Authentication flaw

OpenClinic version 0.8.2 is affected by a missing authentication vulnerability that allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information PHI stored in the application, via a direct request for the /tests/ URI...

5CVSS7.6AI score0.00634EPSS
Exploits1References1Affected Software1
NVD
NVD
added 2020/06/29 2:15 p.m.12 views

CVE-2020-12016

Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account...

10CVSS0.00206EPSS
Exploits0References1
NVD
NVD
added 2020/06/29 2:15 p.m.9 views

CVE-2020-12032

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI...

9.1CVSS0.0011EPSS
Exploits0References1
Prion
Prion
added 2020/06/29 2:15 p.m.12 views

Hardcoded credentials

Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to th...

3.6CVSS6.5AI score0.00067EPSS
Exploits0References1Affected Software2
Prion
Prion
added 2020/06/29 2:15 p.m.14 views

Design/Logic Flaw

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI...

6.4CVSS8.8AI score0.0011EPSS
Exploits0References1Affected Software2
CVE
CVE
added 2020/06/29 1:54 p.m.49 views

CVE-2020-12012

CVE-2020-12012 affects Baxter ExactaMix EM2400 and EM1200 systems (versions listed in connected documents). The root cause is hard-coded administrative credentials in the ExactaMix application, enabling an attacker with physical access to view/update system configuration and data, potentially exp...

6.1CVSS6.2AI score0.00067EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:53 p.m.14 views

CVE-2020-12008

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI...

7.3AI score0.00114EPSS
Exploits0References1
CVE
CVE
added 2020/06/29 1:53 p.m.46 views

CVE-2020-12008

CVE-2020-12008 affects Baxter ExactaMix EM 2400 (versions 1.10, 1.11) and ExactaMix EM1200 (versions 1.1, 1.2), where cleartext transmission of order information can expose PHI over the network. The connected Red Hat and ICS advisories corroborate the issue as a cleartext data exposure vulnerabil...

7.5CVSS7.2AI score0.00114EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:53 p.m.17 views

CVE-2020-12032

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI...

8.9AI score0.0011EPSS
Exploits0References1
CVE
CVE
added 2020/06/29 1:53 p.m.51 views

CVE-2020-12032

CVE-2020-12032 concerns Baxter ExactaMix EM 2400 (versions 1.10–1.11 and 1.13–1.14 per ICS update) and ExactaMix EM1200 (versions 1.1–1.2, 1.4–1.5 per ICS advisory) where device data is stored in an unencrypted database, enabling a network-attacker to view or modify sensitive data including PHI. ...

9.1CVSS8.7AI score0.0011EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:51 p.m.11 views

CVE-2020-12024

Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to th...

6AI score0.00067EPSS
Exploits0References1
CVE
CVE
added 2020/06/29 1:51 p.m.58 views

CVE-2020-12024

CVE-2020-12024 affects Baxter ExactaMix EM2400 (versions 1.10, 1.11, 1.13, 1.14) and ExactaMix EM1200 (versions 1.1, 1.2, 1.4, 1.5). Root cause: inadequate restriction of USB interface access by unauthorized users with physical access, enabling loading of unauthorized payloads or direct hard driv...

6.1CVSS5.9AI score0.00067EPSS
Exploits0References1Affected Software1
ICS
ICS
added 2020/06/18 12:0 a.m.146 views

Baxter ExactaMix (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Baxter Equipment: Baxter ExactaMix EM 2400 & EM 1200 Vulnerabilities: Use of Hard-coded Password, Cleartext Transmission of Sensitive Data, Missing Encryption of Sensitive Data, Improper Access...

10CVSS9.3AI score0.94022EPSS
Exploits46References5
Hacker One
Hacker One
added 2020/05/18 11:11 p.m.25 views

U.S. Dept Of Defense: PII/PHI data available on web https://████████Portals/22/Documents/Meetings

Summary: https://███Portals/22/Documents/Meetings contains many internal documents which likely were reviewed on meeting/meetings preparations which should not be available for public but searchable via google/bing. Documents include: resumes, bio data form, emails including history of medical...

Exploits0
Carbon Black Blog
Carbon Black Blog
added 2020/03/16 3:0 p.m.39 views

New Osterman Research Report | Cyber Security in Healthcare

In 2019, roughly 45 million healthcare records were breached in the United States. With ransomware as their go-to technique, cyber attackers are targeting healthcare providers, medical devices, and critical supply chains more than ever before. The latest Osterman Research report, “Cyber Security ...

0.1AI score
Exploits0
ThreatPost
ThreatPost
added 2020/01/23 8:2 p.m.85 views

Critical, Unpatched 'MDhex' Bugs Threaten Hospital Devices

A collection of six cybersecurity vulnerabilities in a range of GE Healthcare devices for hospitals has been discovered. Dubbed “MDhex” by the researchers at CyberMDX who discovered them, the bugs would allow attackers to disable the devices, harvest personal health information PHI, change alarm...

10CVSS0.8AI score0.00284EPSS
Exploits0References6
Rows per page
Query Builder