•added 2016/07/15 4:59 p.m.•28 views

Hardcoded credentials

Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors...

10CVSS7.9AI score0.0579EPSS
SaveExploits0References3Affected Software1
CVE
CVE
•added 2016/07/15 4:00 p.m.•67 views

CVE-2016-4520

CVE-2016-4520 affects Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14, which contains hard-coded credentials that may allow remote attackers to gain access and, consequently, execute arbitrary code. The vulnerability is exploitable remotely over the netwo...

10CVSS9.4AI score0.0579EPSS
SaveExploits0References3Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/07/15 12:00 a.m.•11 views

CVE-2016-4520: Undefined Security Weakness

Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors...

10CVSS8.5AI score0.0579EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2016/07/15 12:00 a.m.•6 views

PT-2016-5998

Name of the Vulnerable Software and Affected Versions Schneider Electric Pelco Digital Sentry Video Management System versions prior to 7.14 Description The issue concerns hardcoded credentials in the system, allowing remote attackers to gain access and execute arbitrary code through unspecified...

10CVSS0.0579EPSS
SaveExploits0References5
ICS
ICS
•added 2015/12/13 7:00 a.m.•56 views

Schneider Electric Pelco DS-NVs Buffer Overflow Vulnerability

OVERVIEW NCCIC/ICS-CERT received a report from HP’s Zero Day Initiative ZDI concerning a buffer overflow vulnerability in Schneider Electric’s Pelco DS-NVs software package. This vulnerability was reported to ZDI by security researchers Ariele Caltabiano and Andrea Micalizzi. Schneider Electric h...

7.5CVSS7.4AI score0.0356EPSS
SaveExploits0References10
Check Point Advisories
Check Point Advisories
•added 2015/03/29 12:00 a.m.•34 views

Schneider Electric Pelco DS-NVs Rvctl.RVControl Buffer Overflow (CVE-2015-0982)

A buffer overflow vulnerability exists in Schneider Electric Pelco DS-NV Software package. The vulnerability is due to insufficient input validation on a user-supplied input in the SetText method before it is copied into a fixed length buffer on stack. A remote unauthenticated attacker can exploi...

7.5CVSS3AI score0.0356EPSS
SaveExploits0
CNVD
CNVD
•added 2015/03/17 12:00 a.m.•14 views

Schneider Electric Pelco DS-NVs Buffer Overflow Vulnerability

Schneider Electric Pelco DS-NVs is a suite of IP video management software from Schneider Electric France. A buffer overflow vulnerability exists in the DLL for Schneider Electric Pelco DS-NVs versions prior to 7.8.90. A remote attacker could exploit this vulnerability to execute arbitrary code...

7.5CVSS7.8AI score0.0356EPSS
SaveExploits0References1
NVD
NVD
•added 2015/03/14 1:59 a.m.•36 views

CVE-2015-0982

Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors...

7.5CVSS7.9AI score0.0356EPSS
SaveExploits0References2
Prion
Prion
•added 2015/03/14 1:59 a.m.•25 views

Buffer overflow

Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors...

7.5CVSS8.5AI score0.0356EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2015/03/14 1:00 a.m.•43 views

CVE-2015-0982

Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors...

7.9AI score0.0356EPSS
SaveExploits0References2
CVE
CVE
•added 2015/03/14 1:00 a.m.•79 views

CVE-2015-0982

The CVE-2015-0982 issue affects Schneider Electric Pelco DS-NVs software. The root cause is a stack-based buffer overflow in the rvctl.dll ActiveX control (RVControl.1) SetText path, allowing remote attackers to trigger arbitrary code execution when a user opens a malicious file or visits a craft...

7.5CVSS8.1AI score0.0356EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2015/03/14 12:00 a.m.•9 views

CVE-2015-0982: Buffer Copy without Checking Size of Input

Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors...

7.5CVSS6.5AI score0.0356EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2015/03/12 12:00 a.m.•5 views

PT-2015-5004

Name of the Vulnerable Software and Affected Versions Schneider Electric Pelco DS-NVs versions prior to 7.8.90 Description The issue is related to a buffer overflow in an unspecified DLL, allowing remote attackers to execute arbitrary code. This can be achieved via unspecified vectors...

7.5CVSS0.0356EPSS