Powertek PDU Buffer Overflow Vulnerability

Powertek is a company that manufactures data center-grade intelligent PDUs Power Distribution Units, i.e., heavy-duty power strips for server racks. The Powertek PDUs suffer from a buffer overflow vulnerability that can be exploited by an attacker to cause disclosure of the active session id of t...

9.8CVSS7.5AI score0.01696EPSS
SaveExploits1References1
Prion
Prion
added 2022/01/28 8:15 p.m.24 views

Cross site scripting

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

4.3CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software2
CVE
CVE
added 2022/01/28 7:9 p.m.56 views

CVE-2021-22814

CVE-2021-22814 describes a Cross-site Scripting (CWE-79) vulnerability in Schneider Electric NMC embedded devices (NMC2 and NMC3) that can cause arbitrary script execution when a malicious file is read and displayed. Affected products span multiple Schneider Electric lines: 1-phase and 3-phase UP...

6.1CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/01/28 7:9 p.m.27 views

CVE-2021-22814

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

6.5AI score0.00745EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/01/28 7:9 p.m.41 views

CVE-2021-22813

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products:...

6.4AI score0.00745EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/01/28 7:9 p.m.26 views

CVE-2021-22811

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply UP...

6.5AI score0.00745EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2021/12/14 12:0 a.m.28 views

Schneider Electric Rack PDU 信息泄露漏洞

Schneider Electric Rack PDUs are APC switched rack power distribution units PDUs from Schneider-electric in France that support advanced, user-customizable power control and active monitoring. An information disclosure vulnerability exists in the Schneider Electric Rack PDU, which can be exploite...

8CVSS7.7AI score0.00774EPSS
SaveExploits0References6
ICS
ICS
added 2021/12/14 12:0 a.m.80 views

Schneider Electric Rack PDU (Update A)

1. EXECUTIVE SUMMARY --------- Begin Update A Part 1 of 3 --------- CVSS v3 6.5 ATTENTION: Exploitable remotely --------- End Update A Part 1 of 3 --------- Vendor: Schneider Electric Equipment: Rack Power Distribution Unit PDU --------- Begin Update A Part 2 of 3 --------- Vulnerability:...

8CVSS8.1AI score0.00774EPSS
SaveExploits0References4
Prion
Prion
added 2021/10/19 7:15 p.m.17 views

Design/Logic Flaw

A Protection Mechanism Failure vulnerability in RPD routing protocol daemon of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent unauthenticated attacker to cause established IS-IS adjacencies to go down by sending a spoofed hello PDU leading to a Denial of Service DoS condition...

3.3CVSS6.4AI score0.00409EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2021/10/19 6:16 p.m.24 views

CVE-2021-31362 Junos OS and Junos OS Evolved: An IS-IS adjacency might be taken down if a bad hello PDU is received for an existing adjacency causing a DoS

A Protection Mechanism Failure vulnerability in RPD routing protocol daemon of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent unauthenticated attacker to cause established IS-IS adjacencies to go down by sending a spoofed hello PDU leading to a Denial of Service DoS condition...

6.5CVSS6.6AI score0.00409EPSS
SaveExploits0References1
NVD
NVD
added 2021/07/30 2:15 p.m.31 views

CVE-2021-37594

In FreeRDP before 2.4.0 on Windows, wfcliprdrserverfilecontentsrequest in client/Windows/wfcliprdr.c has missing input checks for a FILECONTENTSSIZE File Contents Request PDU...

9.8CVSS0.01409EPSS
SaveExploits0References2
UbuntuCve
UbuntuCve
added 2021/07/30 2:15 p.m.28 views

CVE-2021-37594

In FreeRDP before 2.4.0 on Windows, wfcliprdrserverfilecontentsrequest in client/Windows/wfcliprdr.c has missing input checks for a FILECONTENTSSIZE File Contents Request PDU...

9.8CVSS7.2AI score0.01409EPSS
SaveExploits0References2
UbuntuCve
UbuntuCve
added 2021/07/30 2:15 p.m.35 views

CVE-2021-37595

In FreeRDP before 2.4.0 on Windows, wfcliprdrserverfilecontentsrequest in client/Windows/wfcliprdr.c has missing input checks for a FILECONTENTSRANGE File Contents Request PDU...

9.8CVSS7.2AI score0.01516EPSS
SaveExploits0References2
Debian CVE
Debian CVE
added 2021/07/27 11:33 p.m.23 views

CVE-2021-37594

In FreeRDP before 2.4.0 on Windows, wfcliprdrserverfilecontentsrequest in client/Windows/wfcliprdr.c has missing input checks for a FILECONTENTSSIZE File Contents Request PDU...

9.8CVSS9.6AI score0.01409EPSS
SaveExploits0
Rosalinux
Rosalinux
added 2021/07/02 5:32 p.m.53 views

Advisory ROSA-SA-2021-1929

Software: net-snmp 5.7.2 OS: Cobalt 7.9 CVE-ID: CVE-2014-2284 CVE-Crit: HIGH CVE-DESC: The Linux implementation of ICMP-MIB in Net-SNMP 5.5 through 5.5.2.1, 5.6.x through 5.6.2.1, and 5.7.x through 5.7.2.1 incorrectly validates input, allowing remote attackers to cause a denial of service via...

9.8CVSS8.8AI score0.40002EPSS
SaveExploits7
RedhatCVE
RedhatCVE
added 2021/03/16 2:32 p.m.16 views

CVE-2021-28361

A flaw was found in the SPDK iSCSI target. A NULL pointer dereference resulted from a text PDU sent with a zero-length, resulting in a crash of the SPDK iCSCI target process. The highest threat from this vulnerability is to system availability...

7.5CVSS0.8AI score0.0114EPSS
SaveExploits0References4
Prion
Prion
added 2021/03/13 7:15 p.m.19 views

Null pointer dereference

An issue was discovered in Storage Performance Development Kit SPDK before 20.01.01. If a PDU is sent to the iSCSI target with a zero length but data is expected, the iSCSI target can crash with a NULL pointer dereference...

5CVSS7.4AI score0.0114EPSS
SaveExploits0References1Affected Software1
ATTACKERKB
ATTACKERKB
added 2021/03/13 7:15 p.m.2 views

CVE-2021-28361

An issue was discovered in Storage Performance Development Kit SPDK before 20.01.01. If a PDU is sent to the iSCSI target with a zero length but data is expected, the iSCSI target can crash with a NULL pointer dereference...

7.5CVSS7.2AI score0.0114EPSS
SaveExploits0References2
NVD
NVD
added 2020/11/02 7:15 a.m.24 views

CVE-2020-11154

u'Buffer overflow while processing a crafted PDU data packet in bluetooth due to lack of check of buffer size before copying' in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Consumer Electronics Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdrag...

8.8CVSS8.8AI score0.0051EPSS
SaveExploits0References2
NVD
NVD
added 2020/11/02 7:15 a.m.23 views

CVE-2020-11155

u'Buffer overflow while processing PDU packet in bluetooth due to lack of check of buffer length before copying into it.' in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Consumer Electronics Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon...

8.8CVSS9AI score0.0051EPSS
SaveExploits0References2
Rows per page
Query Builder