520 matches found
Powertek PDU Buffer Overflow Vulnerability
Powertek is a company that manufactures data center-grade intelligent PDUs Power Distribution Units, i.e., heavy-duty power strips for server racks. The Powertek PDUs suffer from a buffer overflow vulnerability that can be exploited by an attacker to cause disclosure of the active session id of t...
Cross site scripting
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...
CVE-2021-22814
CVE-2021-22814 describes a Cross-site Scripting (CWE-79) vulnerability in Schneider Electric NMC embedded devices (NMC2 and NMC3) that can cause arbitrary script execution when a malicious file is read and displayed. Affected products span multiple Schneider Electric lines: 1-phase and 3-phase UP...
CVE-2021-22814
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...
CVE-2021-22813
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products:...
CVE-2021-22811
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply UP...
Schneider Electric Rack PDU 信息泄露漏洞
Schneider Electric Rack PDUs are APC switched rack power distribution units PDUs from Schneider-electric in France that support advanced, user-customizable power control and active monitoring. An information disclosure vulnerability exists in the Schneider Electric Rack PDU, which can be exploite...
Schneider Electric Rack PDU (Update A)
1. EXECUTIVE SUMMARY --------- Begin Update A Part 1 of 3 --------- CVSS v3 6.5 ATTENTION: Exploitable remotely --------- End Update A Part 1 of 3 --------- Vendor: Schneider Electric Equipment: Rack Power Distribution Unit PDU --------- Begin Update A Part 2 of 3 --------- Vulnerability:...
Design/Logic Flaw
A Protection Mechanism Failure vulnerability in RPD routing protocol daemon of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent unauthenticated attacker to cause established IS-IS adjacencies to go down by sending a spoofed hello PDU leading to a Denial of Service DoS condition...
CVE-2021-31362 Junos OS and Junos OS Evolved: An IS-IS adjacency might be taken down if a bad hello PDU is received for an existing adjacency causing a DoS
A Protection Mechanism Failure vulnerability in RPD routing protocol daemon of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent unauthenticated attacker to cause established IS-IS adjacencies to go down by sending a spoofed hello PDU leading to a Denial of Service DoS condition...
CVE-2021-37594
In FreeRDP before 2.4.0 on Windows, wfcliprdrserverfilecontentsrequest in client/Windows/wfcliprdr.c has missing input checks for a FILECONTENTSSIZE File Contents Request PDU...
CVE-2021-37594
In FreeRDP before 2.4.0 on Windows, wfcliprdrserverfilecontentsrequest in client/Windows/wfcliprdr.c has missing input checks for a FILECONTENTSSIZE File Contents Request PDU...
CVE-2021-37595
In FreeRDP before 2.4.0 on Windows, wfcliprdrserverfilecontentsrequest in client/Windows/wfcliprdr.c has missing input checks for a FILECONTENTSRANGE File Contents Request PDU...
CVE-2021-37594
In FreeRDP before 2.4.0 on Windows, wfcliprdrserverfilecontentsrequest in client/Windows/wfcliprdr.c has missing input checks for a FILECONTENTSSIZE File Contents Request PDU...
Advisory ROSA-SA-2021-1929
Software: net-snmp 5.7.2 OS: Cobalt 7.9 CVE-ID: CVE-2014-2284 CVE-Crit: HIGH CVE-DESC: The Linux implementation of ICMP-MIB in Net-SNMP 5.5 through 5.5.2.1, 5.6.x through 5.6.2.1, and 5.7.x through 5.7.2.1 incorrectly validates input, allowing remote attackers to cause a denial of service via...
CVE-2021-28361
A flaw was found in the SPDK iSCSI target. A NULL pointer dereference resulted from a text PDU sent with a zero-length, resulting in a crash of the SPDK iCSCI target process. The highest threat from this vulnerability is to system availability...
Null pointer dereference
An issue was discovered in Storage Performance Development Kit SPDK before 20.01.01. If a PDU is sent to the iSCSI target with a zero length but data is expected, the iSCSI target can crash with a NULL pointer dereference...
CVE-2021-28361
An issue was discovered in Storage Performance Development Kit SPDK before 20.01.01. If a PDU is sent to the iSCSI target with a zero length but data is expected, the iSCSI target can crash with a NULL pointer dereference...
CVE-2020-11154
u'Buffer overflow while processing a crafted PDU data packet in bluetooth due to lack of check of buffer size before copying' in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Consumer Electronics Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdrag...
CVE-2020-11155
u'Buffer overflow while processing PDU packet in bluetooth due to lack of check of buffer length before copying into it.' in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Consumer Electronics Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon...