Lucene search
+L

11 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/12/10 12:00 a.m.•4 views

CVE-2024-54005: Improper Restriction of XML External Entity Reference

A vulnerability has been identified in COMOS V10.3 All versions V10.3.3.5.8, COMOS V10.4.0 All versions, COMOS V10.4.1 All versions, COMOS V10.4.2 All versions, COMOS V10.4.3 All versions V10.4.3.0.47, COMOS V10.4.4 All versions V10.4.4.2, COMOS V10.4.4.1 All versions V10.4.4.1.21. The PDMS/E3D...

5.9CVSS5.7AI score0.00157EPSS
SaveExploits0References1
NVD
NVD
•added 2020/06/29 2:15 p.m.•41 views

CVE-2020-12036

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS0.00496EPSS
SaveExploits0References1
NVD
NVD
•added 2020/06/29 2:15 p.m.•38 views

CVE-2020-12037

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS0.00483EPSS
SaveExploits0References2
Prion
Prion
•added 2020/06/29 2:15 p.m.•26 views

Design/Logic Flaw

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

5CVSS7.4AI score0.00483EPSS
SaveExploits0References2Affected Software1
Prion
Prion
•added 2020/06/29 2:15 p.m.•26 views

Design/Logic Flaw

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

5CVSS7.4AI score0.00496EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2020/06/29 1:49 p.m.•43 views

CVE-2020-12036

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.4AI score0.00496EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2020/06/29 1:49 p.m.•32 views

CVE-2020-12037

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.4AI score0.00483EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/06/29 12:00 a.m.•6 views

CVE-2020-12036: Cleartext Transmission of Sensitive Information

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS5.7AI score0.00496EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2020/06/29 12:00 a.m.•2 views

PT-2020-13004

Name of the Vulnerable Software and Affected Versions Baxter PrismaFlex all versions PrisMax versions prior to 3.x Description The affected devices do not implement data-in-transit encryption, such as TLS/SSL, when sending treatment data to a Patient Data Management System PDMS or an Electronic...

7.5CVSS0.00483EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2020/06/29 12:00 a.m.•2 views

PT-2020-13003

Name of the Vulnerable Software and Affected Versions Baxter PrismaFlex all versions PrisMax versions prior to 3.x Description The affected devices do not implement data-in-transit encryption, such as TLS/SSL, when sending treatment data to a Patient Data Management System PDMS or an Electronic...

7.5CVSS0.00496EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/06/29 12:00 a.m.•7 views

CVE-2020-12037: Use of Hard-coded Password

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS5.7AI score0.00483EPSS
SaveExploits0References3
Rows per page
Query Builder