Lucene search
+L

6 matches found

NVD
NVD
added 2020/06/29 2:15 p.m.35 views

CVE-2020-12036

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS0.00496EPSS
SaveExploits0References1
NVD
NVD
added 2020/06/29 2:15 p.m.29 views

CVE-2020-12037

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS0.00483EPSS
SaveExploits0References2
Prion
Prion
added 2020/06/29 2:15 p.m.22 views

Design/Logic Flaw

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

5CVSS7.4AI score0.00496EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2020/06/29 2:15 p.m.21 views

Design/Logic Flaw

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

5CVSS7.4AI score0.00483EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:49 p.m.35 views

CVE-2020-12036

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.4AI score0.00496EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/06/29 1:49 p.m.24 views

CVE-2020-12037

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.4AI score0.00483EPSS
SaveExploits0References1
Rows per page