89 matches found
CVE-2022-34278
Siemens PADS Standard/Plus Viewer (All versions) is affected by CVE-2022-34278 due to an out-of-bounds read when parsing PCB files, which could allow code execution in the context of the current process. The issue is documented across multiple sources (e.g., Red Hat, CNVD, CNVD- CNVD-2022-51619; ...
CVE-2022-34277
A vulnerability has been identified in PADS Standard/Plus Viewer All versions. The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. This could allow an attacker to execute code in the context of the current process. FG-VD-22-0...
CVE-2022-34276
CVE-2022-34276 affects Siemens PADS Standard/Plus Viewer (All versions). The issue is an out-of-bounds write past the end of an allocated structure when parsing specially crafted PCB files, allowing code execution in the current process. Exploitation discussed as possible when a user opens a mali...
CVE-2022-34275
A vulnerability has been identified in PADS Standard/Plus Viewer All versions. The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current...
CVE-2022-34274
Siemens PADS Standard/Plus Viewer (All versions) is affected by CVE-2022-34274 due to an out-of-bounds write past the end of an allocated structure while parsing PCB files, enabling code execution in the current process context. Several sources (including Red Hat advisory, CNVD, CNVD-derived CVEs...
CVE-2022-34273
A vulnerability has been identified in PADS Standard/Plus Viewer All versions. The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current...
CVE-2022-34272
CVE-2022-34272 affects Siemens PADS Standard/Plus Viewer (all versions). Affected component: PCB file parsing; vulnerability is an out-of-bounds read past end of allocated buffer, enabling potential code execution in the current process (FG-VD-22-037, FG-VD-22-059). CVSSv3 base score 7.8 (local, ...
CVE-2022-34272
A vulnerability has been identified in PADS Standard/Plus Viewer All versions. The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current...
Siemens PADS Standard/Plus Viewer
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: PADS Standard/Plus Viewer Vulnerabilities: Out-of-bounds Read, Out-of-bounds Write, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitations of...