20 matches found
CVE-2023-5246
Authentication Bypass by Capture-replay in SICK Flexi Soft Gateways with Partnumbers 1044073, 1127717, 1130282, 1044074, 1121597, 1099832, 1051432, 1127487, 1069070, 1112296, 1044072, 1121596, 1099830 allows an unauthenticated remote attacker to potentially impact the availability, integrity and...
Authentication flaw
Authentication Bypass by Capture-replay in SICK Flexi Soft Gateways with Partnumbers 1044073, 1127717, 1130282, 1044074, 1121597, 1099832, 1051432, 1127487, 1069070, 1112296, 1044072, 1121596, 1099830 allows an unauthenticated remote attacker to potentially impact the availability, integrity and...
CVE-2023-5246
CVE-2023-5246 affects SICK Flexi Soft Gateways with partnumbers 1044073, 1127717, 1130282, 1044074, 1121597, 1099832, 1051432, 1127487, 1069070, 1112296, 1044072, 1121596, 1099830. The issue is an authentication bypass by capture-replay that could allow an unauthenticated remote attacker to impac...
CVE-2023-5246
Authentication Bypass by Capture-replay in SICK Flexi Soft Gateways with Partnumbers 1044073, 1127717, 1130282, 1044074, 1121597, 1099832, 1051432, 1127487, 1069070, 1112296, 1044072, 1121596, 1099830 allows an unauthenticated remote attacker to potentially impact the availability, integrity and...
CVE-2023-23445
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to gain unauthorized access to data fields by using a therefore unpriviledged account via the REST interface...
CVE-2023-23446
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface...
CVE-2023-23449
Observable Response Discrepancy in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to gain information about valid usernames by analyzing challenge responses from the server via the REST interface...
CVE-2023-31409
Uncontrolled Resource Consumption in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an remote attacker to influence the availability of the webserver by invocing a Slowloris style attack via HTTP requests...
CVE-2023-23450
Use of Password Hash Instead of Password for Authentication in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to use a password hash instead of an actual password to login to a valid user account via...
CVE-2023-31408
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to potentially steal user credentials that are stored in the user’s browsers local storage via cross-site-scripting attac...
Open redirect
Uncontrolled Resource Consumption in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to influence the availability of the webserver by invocing several open file requests via the REST interface...
Improper access control
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to gain unauthorized access to data fields by using a therefore unpriviledged account via the REST interface...
CVE-2023-31409
CVE-2023-31409 affects SICK FTMg AIR FLOW SENSOR (partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526). The vulnerability enables a remote attacker to exhaust resources and impact availability of the webserver by invoking a Slowloris-style attack over HTTP. Root cause detail...
CVE-2023-31408
The CVE-2023-31408 entry affects the SICK FTMg AIR FLOW SENSOR (partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526). Root cause: cleartext storage of sensitive information in the browser’s local storage, enabling potential exposure through cross-site scripting. Impact state...
CVE-2023-31408
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to potentially steal user credentials that are stored in the user’s browsers local storage via cross-site-scripting attac...
CVE-2023-23447
Uncontrolled Resource Consumption in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to influence the availability of the webserver by invocing several open file requests via the REST interface...
CVE-2023-23446
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface...
CVE-2023-23445
CVE-2023-23445 affects SICK FTMg AIR FLOW SENSOR (partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526). The root cause is Improper Access Control allowing an unprivileged remote attacker to access data fields via the REST interface. The CVE has a high impact on confidentiali...
CVE-2023-23445
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to gain unauthorized access to data fields by using a therefore unpriviledged account via the REST interface...
CVE-2023-23444
CVE-2023-23444 affects SICK Flexi Classic and Flexi Soft Gateways with partnumbers: 1042193, 1042964, 1044078, 1044072, 1044073, 1044074, 1099830, 1099832, 1127717, 1069070, 1112296, 1051432, 1102420, 1127487, 1121596, 1121597. The issue is a missing authentication for a critical function that al...