Lucene search
+L

46 matches found

CVE
CVE
added 2022/09/06 10:15 a.m.101 views

CVE-2022-2714

RosarioSIS (francoisjacquet/rosariosis) is affected by CVE-2022-2714 due to improper handling of length parameter inconsistencies. Public sources converge on affected versions being prior to 10.0 (Red Hat) and prior to 10.1 (GitHub advisory), indicating fixes are in 10.0/10.1 and later. A concret...

9.8CVSS9AI score0.00781EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2022/09/06 10:15 a.m.46 views

CVE-2022-2714 Improper Handling of Length Parameter Inconsistency in francoisjacquet/rosariosis

Improper Handling of Length Parameter Inconsistency in GitHub repository francoisjacquet/rosariosis prior to 10.0...

8.1CVSS9.8AI score0.00781EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2022/05/05 3:17 p.m.9 views

CVE-2021-38445 OCI OpenDDS Secure Improper Handling of Length Parameter Inconsistency

OCI OpenDDS versions prior to 3.18.1 do not handle a length parameter consistent with the actual length of the associated data, which may allow an attacker to remotely execute arbitrary code...

7CVSS7.3AI score0.02519EPSS
SaveExploits0References2
OSV
OSV
added 2022/04/07 7:15 p.m.10 views

CVE-2022-0677

Improper Handling of Length Parameter Inconsistency vulnerability in the Update Server component of Bitdefender Endpoint Security Tools in relay role, GravityZone in Update Server role allows an attacker to cause a Denial-of-Service. This issue affects: Bitdefender Update Server versions prior to...

7.5CVSS5.8AI score0.01229EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/04/07 6:21 p.m.28 views

CVE-2022-0677 Improper Handling of Length Parameter Inconsistency vulnerability in Bitdefender Update Server (VA-10144)

Improper Handling of Length Parameter Inconsistency vulnerability in the Update Server component of Bitdefender Endpoint Security Tools in relay role, GravityZone in Update Server role allows an attacker to cause a Denial-of-Service. This issue affects: Bitdefender Update Server versions prior to...

7.5CVSS7.5AI score0.01229EPSS
SaveExploits0References1
OSV
OSV
added 2021/12/17 5:15 p.m.10 views

CVE-2021-20608

Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sendin...

7.5CVSS5.8AI score0.02711EPSS
SaveExploits0References3
CVE
CVE
added 2021/12/17 4:10 p.m.60 views

CVE-2021-20608

CVE-2021-20608 concerns Mitsubishi Electric GX Works2. The issue is an improper handling of a length parameter inconsistency when reading a tampered program file from a Mitsubishi PLC, which can allow a remote attacker to cause a denial of service in GX Works2. Affected products are GX Works2 ver...

7.5CVSS7.3AI score0.02711EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2021/12/01 3:41 p.m.31 views

CVE-2021-20610

Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU, MELSEC iQ-R Series R04/08/16/32/120ENCPU, MELSEC iQ-R Series R08/16/32/120SFCPU, MELSEC iQ-R Series R08/16/32/120PCPU, MELSEC iQ-R Series R08/16/32/120PSFCPU, MELSEC iQ-R Seri...

7.5CVSS7.7AI score0.03077EPSS
SaveExploits0References3
Github Security Blog
Github Security Blog
added 2021/08/02 4:55 p.m.103 views

Improper Handling of Length Parameter Inconsistency in Compress

When reading a specially crafted 7Z archive, Compress can be made to allocate large amounts of memory that finally leads to an out of memory error even for very small inputs. This could be used to mount a denial of service attack against services that use Compress' sevenz package...

7.5CVSS7.3AI score0.12365EPSS
SaveExploits0References20Affected Software1
OSV
OSV
added 2021/05/25 5:15 p.m.7 views

CVE-2020-10065

Missing Size Checks in Bluetooth HCI over SPI. Zephyr versions = v1.14.2, = v2.2.0 contain Improper Handling of Length Parameter Inconsistency CWE-130. For more information, see https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-hg2w-62p6-g67c...

8.8CVSS5.5AI score0.00486EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2021/05/24 9:40 p.m.28 views

CVE-2020-10065 Missing Size Checks in Bluetooth HCI over SPI

Missing Size Checks in Bluetooth HCI over SPI. Zephyr versions = v1.14.2, = v2.2.0 contain Improper Handling of Length Parameter Inconsistency CWE-130. For more information, see https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-hg2w-62p6-g67c...

3.8CVSS8.7AI score0.00486EPSS
SaveExploits0References1
OSV
OSV
added 2021/02/19 8:15 p.m.11 views

CVE-2021-20588

Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR...

9.8CVSS6AI score0.06881EPSS
SaveExploits0References5
ICS
ICS
added 2021/02/16 12:00 a.m.59 views

Rockwell Automation Allen-Bradley Micrologix 1100

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: Allen-Bradley MicroLogix 1100 Vulnerability: Improper Handling of Length Parameter Inconsistency 2. RISK EVALUATION Successful exploitation of this vulnerability...

7.5CVSS7.8AI score0.04584EPSS
SaveExploits0References4
NVD
NVD
added 2020/11/30 10:15 p.m.30 views

CVE-2020-16849

An issue was discovered on Canon MF237w 06.07 devices. An "Improper Handling of Length Parameter Inconsistency" issue in the IPv4/ICMPv4 component, when handling a packet sent by an unauthenticated network attacker, may expose Sensitive Information...

7.5CVSS7.6AI score0.0113EPSS
SaveExploits0References2
Prion
Prion
added 2020/06/17 11:15 a.m.14 views

Code injection

The Treck TCP/IP stack before 6.0.1.66 improperly handles a Length Parameter Inconsistency in TCP...

5.8CVSS7.5AI score0.0196EPSS
SaveExploits1References10Affected Software1
CVE
CVE
added 2020/06/17 10:47 a.m.184 views

CVE-2020-11907

CVE-2020-11907 concerns the Treck TCP/IP stack before version 6.0.1.66, which allegedly “improperly handles a Length Parameter Inconsistency in TCP.” The initial description lists an Adjacent Network attack vector with Low attack complexity and no authentication, and CVSS scores: CVSS2 base 5.8 (...

6.3CVSS7.4AI score0.0196EPSS
SaveIn wildExploits1References10Affected Software1
Cvelist
Cvelist
added 2020/06/17 10:47 a.m.23 views

CVE-2020-11907

The Treck TCP/IP stack before 6.0.1.66 improperly handles a Length Parameter Inconsistency in TCP...

7.6AI score0.0196EPSS
SaveExploits1References10
ICS
ICS
added 2020/06/16 6:00 a.m.398 views

Treck TCP/IP (Update I)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION : Exploitable remotely/low attack complexity Vendor : Treck Inc. Equipment : TCP/IP Vulnerabilities : Improper Handling of Length Parameter Inconsistency, Improper Input Validation, Double Free, Out-of-bounds Read, Integer Overflow or...

10CVSS8.3AI score0.36852EPSS
SaveExploits14References10
Cvelist
Cvelist
added 2018/03/05 5:00 p.m.26 views

CVE-2018-5453

An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable...

7.4AI score0.01182EPSS
SaveExploits0References1
CVE
CVE
added 2018/03/05 5:00 p.m.50 views

CVE-2018-5453

CVE-2018-5453 affects the Moxa OnCell G3100-HSPA Series (version 1.4 Build 16062919 and prior). The vulnerability is described as an improper handling of length parameter inconsistency, allowing an attacker to edit an element of an HTTP request and potentially render the device unavailable. The N...

7.8CVSS7.3AI score0.01182EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder