Lucene search
K

9 matches found

Malwarebytes
Malwarebytes
added 2023/07/06 3:0 a.m.14 views

Warning issued over vulnerability in cardiac device monitoring software

The Cybersecurity and Infrastructure Security Agency CISA has issued a warning about a vulnerability that could result in remote code execution or a denial-of-service DoS condition impacting a healthcare delivery organizations Paceart Optima system. Paceart Optima is a software application that...

6.5CVSS8AI score0.25503EPSS
Exploits0
NVD
NVD
added 2023/06/29 4:15 p.m.9 views

CVE-2023-31222

Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or...

9.8CVSS9.4AI score0.25503EPSS
Exploits0References1
OSV
OSV
added 2023/06/29 4:15 p.m.0 views

CVE-2023-31222

Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or...

8.8CVSS5.8AI score0.25503EPSS
Exploits0References1
Prion
Prion
added 2023/06/29 4:15 p.m.15 views

Deserialization of untrusted data

Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or...

6.5CVSS8.5AI score0.25503EPSS
Exploits0References1Affected Software1
CVE
CVE
added 2023/06/29 3:19 p.m.30 views

CVE-2023-31222

CVE-2023-31222 affects Medtronic Paceart Optima, specifically versions 1.11 and earlier, where Deserialization of untrusted data via the Microsoft Messaging Queuing Service in Paceart Messaging Service can allow an unauthenticated, network-accessing attacker to impact a Paceart Optima cardiac dev...

9.8CVSS8.9AI score0.25503EPSS
Exploits0References1Affected Software1
CISA
CISA
added 2023/06/29 12:0 p.m.2 views

CISA Releases Nine Industrial Control Systems Advisories

CISA released nine Industrial Control Systems ICS advisories on June 29, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-23-180-01 Delta Electronics InfraSuite Device Master ICSA-23-180-02 Schneider Electric...

7AI score
Exploits0References9
ICS
ICS
added 2023/06/29 6:0 a.m.17 views

Medtronic Paceart Optima System

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Medtronic Equipment: Paceart Optima System Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could result in remote code execution or a...

9.8CVSS9.3AI score0.25503EPSS
Exploits0References8
CNNVD
CNNVD
added 2023/06/29 12:0 a.m.4 views

Medtronic Paceart Optima 代码问题漏洞

Medtronic Paceart Optima is a comprehensive workflow solution from Medtronic, Inc. to efficiently compile and manage patient cardiac device data. A security vulnerability exists in Medtronic Paceart Optima version 1.11 and prior versions that originates from a data deserialization issue in...

9.8CVSS8.1AI score0.25503EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2023/04/25 12:0 a.m.3 views

PT-2023-3388 · Medtronic +1 · Paceart Optima +1

Name of the Vulnerable Software and Affected Versions: Medtronic's Paceart Optima versions 1.11 and earlier Description: The issue is related to the deserialization of untrusted data in the Microsoft Messaging Queuing Service of Medtronic's Paceart Optima system. This allows an unauthorized user ...

10CVSS8.9AI score0.25503EPSS
Exploits0References6