Lucene search
+L

6 matches found

SUSE CVE
SUSE CVE
•added 2025/12/17 12:24 a.m.•14 views

SUSE CVE-2025-68236

In the Linux kernel, the following vulnerability has been resolved: scsi: ufs: ufs-qcom: Fix UFS OCP issue during UFS power down PC=3 According to UFS specifications, the power-off sequence for a UFS device includes: - Sending an SSU command with PowerCondition=3 and await a response. - Asserting...

6.7AI score0.00172EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2025/12/16 2:08 p.m.•42 views

CVE-2025-68236 scsi: ufs: ufs-qcom: Fix UFS OCP issue during UFS power down (PC=3)

In the Linux kernel, the following vulnerability has been resolved: scsi: ufs: ufs-qcom: Fix UFS OCP issue during UFS power down PC=3 According to UFS specifications, the power-off sequence for a UFS device includes: - Sending an SSU command with PowerCondition=3 and await a response. - Asserting...

0.00172EPSS
SaveExploits0References2
CVE
CVE
•added 2025/12/16 2:08 p.m.•42 views

CVE-2025-68236

CVE-2025-68236 affects the Linux kernel’s SCSI UFS stack, specifically the ufs-qcom driver. The issue arises during the UFS power-down sequence: after SSU Power_Condition=3, hardware reset (HWRST) can wake the device firmware, causing a transient surge in ICCQ current. If the regulator is still e...

6.2AI score0.00172EPSS
SaveExploits0References2
OSV
OSV
•added 2025/12/16 2:08 p.m.•11 views

CVE-2025-68236 scsi: ufs: ufs-qcom: Fix UFS OCP issue during UFS power down (PC=3)

In the Linux kernel, the following vulnerability has been resolved: scsi: ufs: ufs-qcom: Fix UFS OCP issue during UFS power down PC=3 According to UFS specifications, the power-off sequence for a UFS device includes: - Sending an SSU command with PowerCondition=3 and await a response. - Asserting...

6.5AI score
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/12/16 12:00 a.m.•1 views

CVE-2025-68236: Undefined Security Weakness

In the Linux kernel, the following vulnerability has been resolved: scsi: ufs: ufs-qcom: Fix UFS OCP issue during UFS power down PC=3 According to UFS specifications, the power-off sequence for a UFS device includes: - Sending an SSU command with PowerCondition=3 and await a response. - Asserting...

5.8AI score0.00172EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2019/10/28 12:00 a.m.•14 views

Siemens SIPROTEC 5 7SA87 Power Systems Monitoring and Protection Device

Binary data 765246.prm...

7.3AI score
SaveExploits0
Rows per page
Query Builder