Lucene search
+L

19825 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/30 12:00 a.m.•7 views

CVE-2025-51958: Improper Neutralization of Special Elements used in an OS Command

aelsantex runcommand 2014-04-01, a plugin for DokuWiki, allows unauthenticated attackers to execute arbitrary system commands via lib/plugins/runcommand/postaction.php...

9.8CVSS6.5AI score0.00692EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/30 12:00 a.m.•7 views

CVE-2026-21418: Improper Neutralization of Special Elements used in an OS Command

Dell Unity, versions 5.5.2 and prior, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root...

7.8CVSS6.3AI score0.00651EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
•added 2026/01/30 12:00 a.m.•18 views

MCP protocol server Command Injection

The vulnerability of the MCP protocol’s codehooks-mcp-server relates to the failure to take measures to neutralize special elements used in the operating system commands. Exploiting this vulnerability allows a remote attacker to execute arbitrary commands...

10CVSS7.3AI score0.01256EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/30 12:00 a.m.•8 views

CVE-2026-1723: Improper Neutralization of Special Elements used in an OS Command

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in TOTOLINK X6000R allows OS Command Injection.This issue affects X6000R: through V9.4.0cu.1498B20250826...

9.2CVSS5.8AI score0.00999EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/30 12:00 a.m.•10 views

CVE-2026-22277: Improper Neutralization of Special Elements used in an OS Command

Dell UnityVSA, versions 5.4 and prior, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root...

7.8CVSS6.3AI score0.00651EPSS
SaveExploits0References1
Metasploit
Metasploit
•added 2026/01/29 12:00 a.m.•349 views

Ivanti Endpoint Manager Mobile (EPMM) unauthenticated RCE

This module exploits a OS command injection issue in Ivanti Endpoint Manager Mobile EPMM, formerly known as MobileIron. A remote attacker can achieve unauthenticated RCE with root privileges on an affected device. Module Options msf use exploit/linux/http/ivanti/epmmrce msf undefinedepmmrce show...

9.8CVSS9AI score0.98688EPSS
SaveExploits7
Vulnrichment
Vulnrichment
•added 2026/01/28 9:32 p.m.•13 views

CVE-2026-1544 D-Link DIR-823X set_mode sub_41E2A0 os command injection

A security flaw has been discovered in D-Link DIR-823X 250416. Impacted is the function sub41E2A0 of the file /goform/setmode. Performing a manipulation of the argument langateway results in os command injection. The attack is possible to be carried out remotely. The exploit has been released to...

6.5CVSS6.5AI score0.03816EPSS
SaveExploits1References5
CVE
CVE
•added 2026/01/28 2:32 a.m.•97 views

CVE-2026-1506

The CVE-2026-1506 entry affects D-Link DIR-615, specifically the MAC Filter Configuration component’s file /adv_mac_filter.php. The vulnerability is an OS command injection triggered by manipulating the mac argument, enabling remote execution. The issue is documented across multiple sources (NVD,...

8.6CVSS7AI score0.0557EPSS
SaveExploits1References5Affected Software1
osv_cve
osv_cve
•added 2026/01/28 2:16 a.m.•22 views

CVE-2026-1505

A vulnerability was found in D-Link DIR-615 4.10. This issue affects some unknown processing of the file /settempnodes.php of the component URL Filter. The manipulation results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used. This...

7.2CVSS6.9AI score0.05066EPSS
SaveExploits1References5
Vulnrichment
Vulnrichment
•added 2026/01/28 1:32 a.m.•14 views

CVE-2026-1505 D-Link DIR-615 URL Filter set_temp_nodes.php os command injection

A vulnerability was found in D-Link DIR-615 4.10. This issue affects some unknown processing of the file /settempnodes.php of the component URL Filter. The manipulation results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used. This...

8.6CVSS6.9AI score0.05066EPSS
SaveExploits1References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/28 12:00 a.m.•9 views

CVE-2026-1505: Improper Neutralization of Special Elements used in an OS Command

A vulnerability was found in D-Link DIR-615 4.10. This issue affects some unknown processing of the file /settempnodes.php of the component URL Filter. The manipulation results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used. This...

8.6CVSS6.9AI score0.05066EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/28 12:00 a.m.•8 views

CVE-2026-1506: Improper Neutralization of Special Elements used in an OS Command

A vulnerability was determined in D-Link DIR-615 4.10. Impacted is an unknown function of the file /advmacfilter.php of the component MAC Filter Configuration. This manipulation of the argument mac causes os command injection. The attack is possible to be carried out remotely. The exploit has bee...

8.6CVSS7AI score0.0557EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/28 12:00 a.m.•8 views

CVE-2026-1544: Improper Neutralization of Special Elements used in an OS Command

A security flaw has been discovered in D-Link DIR-823X 250416. Impacted is the function sub41E2A0 of the file /goform/setmode. Performing a manipulation of the argument langateway results in os command injection. The attack is possible to be carried out remotely. The exploit has been released to...

8.8CVSS6.5AI score0.03816EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/27 12:00 a.m.•11 views

CVE-2026-23592: Improper Neutralization of Special Elements used in an OS Command

Insecure file operations in HPE Aruba Networking Fabric Composer’s backup functionality could allow authenticated attackers to achieve remote code execution. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system...

7.2CVSS6.9AI score0.00862EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/27 12:00 a.m.•8 views

CVE-2026-1448: Improper Neutralization of Special Elements used in an OS Command

A vulnerability was detected in D-Link DIR-615 up to 4.10. This impacts an unknown function of the file /wizpolicy3machine.php of the component Web Management Interface. Performing a manipulation of the argument ipaddr results in os command injection. It is possible to initiate the attack remotel...

8.6CVSS7AI score0.05775EPSS
SaveExploits1References1
EUVD
EUVD
•added 2026/01/26 11:32 p.m.•34 views

EUVD-2026-4734

A vulnerability was detected in D-Link DIR-615 up to 4.10. This impacts an unknown function of the file /wizpolicy3machine.php of the component Web Management Interface. Performing a manipulation of the argument ipaddr results in os command injection. It is possible to initiate the attack remotel...

8.6CVSS7AI score0.05775EPSS
SaveExploits1References5
Cvelist
Cvelist
•added 2026/01/26 8:14 a.m.•46 views

CVE-2026-1428 WellChoose|Single Sign-On Portal System - OS Command Injection

Single Sign-On Portal System developed by WellChoose has a OS Command Injection vulnerability, allowing authenticated remote attackers to inject arbitrary OS commands and execute them on the server...

8.8CVSS0.01376EPSS
SaveExploits0References2
attackerkb
attackerkb
•added 2026/01/26 8:14 a.m.•14 views

CVE-2026-1428

Single Sign-On Portal System developed by WellChoose has a OS Command Injection vulnerability, allowing authenticated remote attackers to inject arbitrary OS commands and execute them on the server...

8.8CVSS6.2AI score0.01376EPSS
SaveExploits0References3
CVE
CVE
•added 2026/01/26 8:06 a.m.•51 views

CVE-2026-1427

CVE-2026-1427 concerns the WellChoose Single Sign-On Portal System, where an OS Command Injection flaw allows authenticated remote attackers to inject and execute arbitrary commands on the server. The connected sources identify the affected product (WellChoose SSO Portal System), and the root cau...

8.8CVSS6.1AI score0.01403EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
•added 2026/01/26 8:06 a.m.•14 views

CVE-2026-1427 WellChoose|Single Sign-On Portal System - OS Command Injection

Single Sign-On Portal System developed by WellChoose has a OS Command Injection vulnerability, allowing authenticated remote attackers to inject arbitrary OS commands and execute them on the server...

8.8CVSS6.1AI score0.01403EPSS
SaveExploits0References2
Rows per page
Query Builder