Lucene search
K

75 matches found

ICS
ICS
added 2026/05/12 12:0 a.m.6 views

Siemens SIMATIC

SUMMARY SIMATIC HMI Unified Comfort Panels before V21.0 are affected by a vulnerability that allows an unauthenticated attacker to access the web browser via the help link. This vulnerability allows an attacker to access the web browser through the Control Panel if it is not protected by the...

7.7CVSS7.3AI score0.00033EPSS
Exploits0References10
ICS
ICS
added 2025/09/09 12:0 a.m.3 views

Siemens User Management Component (UMC)

SUMMARY Siemens' User Management Component UMC is affected by multiple vulnerabilities that could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition. Siemens has released a new version for User Management Component UMC and recommends to...

8.1AI score
Exploits0References10
ICS
ICS
added 2025/07/08 12:0 a.m.4 views

Siemens TIA Administrator

SUMMARY Siemens TIA Administrator before V3.0.6 contains multiple vulnerabilities which could allow an attacker to escalate privilege or exceute arbitrary code during installations. Siemens has released a new version for TIA Administrator and recommends to update to the latest version. 2...

8AI score
Exploits0References10
ICS
ICS
added 2025/06/10 12:0 a.m.4 views

Siemens SCALANCE and RUGGEDCOM

SUMMARY Several Industrial Communication Devices based on SINEC OS before V3.1 contain an incorrect authorization check vulnerability that could allow an attacker to perform actions that exceed the permissions of the "guest" role. Siemens has released new versions for the affected products and...

5.3CVSS5.1AI score0.00571EPSS
Exploits0References10
ICS
ICS
added 2025/06/10 12:0 a.m.3 views

Siemens SCALANCE and RUGGEDCOM

SUMMARY Several Industrial Communication Devices based on SINEC OS before V3.2 contain multiple vulnerabilities that could allow an attacker to circumvent authorization checks and perform actions that exceed the permissions of the "guest" role. Siemens has released new versions for the affected...

5.2AI score
Exploits0References10
ICS
ICS
added 2025/06/10 12:0 a.m.4 views

Siemens Energy Services

SUMMARY Siemens Energy Services previously known as Managed Applications and Services, sell solutions using Elspec G5 Digital Fault Recorder which contains default credentials with admin privileges. A client configuration with remote access could allow an attacker to gain remote control of the...

9.9CVSS9.9AI score0.00284EPSS
Exploits0References10
ICS
ICS
added 2025/05/13 12:0 a.m.2 views

Siemens SIMATIC PCS

SUMMARY Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout. Siemens has released new versions for the affected...

9.8CVSS7.1AI score0.00206EPSS
Exploits0References10
ICS
ICS
added 2025/05/13 12:0 a.m.7 views

Siemens SIMATIC IPC RS-828A

SUMMARY SIMATIC IPC RS-828A is affected by an authentication bypass vulnerability in the Redfish interface of its Baseboard Management Controller BMC that could allow an attacker to gain unauthorized access and compromise confidentiality, integrity and availability of the BMC and thus the entire...

10CVSS7.6AI score0.42969EPSS
Exploits0References10
ICS
ICS
added 2025/05/13 12:0 a.m.4 views

Siemens SCALANCE LPE9403

SUMMARY SCALANCE LPE9403 is affected by multiple vulnerabilities which lead to a compromise in availability, integrity and confidentiality. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. 2. GENERAL RECOMMENDATIONS...

8.8AI score
Exploits0References10
ICS
ICS
added 2025/05/13 12:0 a.m.7 views

Siemens Teamcenter Visualization

SUMMARY Siemens Teamcenter Visualization contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially...

7.8CVSS7.4AI score0.00059EPSS
Exploits0References10
ICS
ICS
added 2025/04/08 12:0 a.m.2 views

Siemens Industrial Edge Devices

SUMMARY Siemens Industrial Edge Devices contain a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new versions for several affected products and recommends to update to...

9.8CVSS7.3AI score0.00897EPSS
Exploits0References10
ICS
ICS
added 2025/04/08 12:0 a.m.3 views

Siemens Industrial Edge Device Kit

SUMMARY Industrial Edge Device Kit contains a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Industrial Edge Device Builders integrate Industrial Edge Device Kit into their offerings...

9.8CVSS7.3AI score0.00897EPSS
Exploits0References10
ICS
ICS
added 2025/04/08 12:0 a.m.3 views

Siemens Solid Edge

SUMMARY Solid Edge is affected by an out of bounds write vulnerability that could be triggered when the application is parsing XT data or a specially crafted file in XT format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the...

7.8CVSS7.9AI score0.00168EPSS
Exploits0References10
ICS
ICS
added 2025/04/08 12:0 a.m.13 views

Siemens License Server (SLS)

SUMMARY Siemens License Server before V4.3 contains various vulnerabilities that could allow a low-privileged local user to escalate privileges or perform arbitrary code execution. Siemens has released a new version for Siemens License Server SLS and recommends to update to the latest version...

7.9AI score
Exploits0References10
ICS
ICS
added 2025/04/08 12:0 a.m.4 views

Siemens Mendix Runtime

SUMMARY Mendix Runtime allows for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application. Siemens has released new versions for several...

6.9CVSS7.1AI score0.004EPSS
Exploits0References10
ICS
ICS
added 2025/03/11 12:0 a.m.3 views

Siemens SINEMA Remote Connect Server

SUMMARY SINEMA Remote Connect Server before V3.2 SP3 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends...

9.5AI score
Exploits0References10
ICS
ICS
added 2025/03/11 12:0 a.m.3 views

Siemens SCALANCE M-800 and SC-600 Families

SUMMARY SCALANCE M-800 and SC-600 families are affected by improper input validation in the OpenVPN authentication. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific...

6.3CVSS6.5AI score0.00115EPSS
Exploits0References10
ICS
ICS
added 2025/02/11 12:0 a.m.4 views

Siemens SIMATIC

SUMMARY The webserver of several SIMATIC products is affected by a user enumeration vulnerability that could allow an unauthenticated remote attacker to identify valid usernames. Siemens has released new versions for several affected products and recommends to update to the latest versions...

6.9CVSS7.2AI score0.00217EPSS
Exploits0References10
ICS
ICS
added 2025/02/11 12:0 a.m.7 views

Siemens SIMATIC PCS neo, TIA Administrator, and TIA Portal

SUMMARY Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout. Siemens has released new versions for several...

8.8CVSS7.2AI score0.00246EPSS
Exploits0References10
ICS
ICS
added 2025/02/11 12:0 a.m.4 views

Siemens OpenV2G

SUMMARY The open source software OpenV2G contains a buffer overflow vulnerability that could allow an attacker to trigger a memory corruption. Siemens has released an update for the OpenV2G and recommends to update to the latest version. 2. GENERAL RECOMMENDATIONS As a general security measure,...

9.8CVSS7.6AI score0.00364EPSS
Exploits0References10
Rows per page
Query Builder