Lucene search
+L

1314 matches found

Cvelist
Cvelist
added 2020/04/22 8:51 p.m.33 views

CVE-2020-8867

This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of OPC Foundation UA .NET Standard 1.04.358.30. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of sessions. The issue results fr...

5.3CVSS7.5AI score0.0258EPSS
SaveExploits0References2
Zero Day Initiative
Zero Day Initiative
added 2020/04/16 12:0 a.m.56 views

(Pwn2Own) OPC Foundation UA .NET Standard CreateSessionRequest Race Condition Denial-of-Service Vulnerability

This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of OPC Foundation UA .NET Standard. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of sessions. The issue results from the lack ...

5.3CVSS0.7AI score0.0258EPSS
SaveExploits0References1
Github Security Blog
Github Security Blog
added 2020/03/16 10:46 p.m.107 views

Insufficient Nonce Validation in Eclipse Milo Client

Impact Credential replay affecting those connected to a server when all 3 of the following conditions are met: - SecurityPolicy is None - using username/password or X509-based authentication - the server has a defect causing it to send null/empty or zeroed nonces Patches The problem has been...

7.4CVSS0.5AI score0.01043EPSS
SaveExploits0References6Affected Software1
NVD
NVD
added 2020/03/16 4:15 p.m.26 views

CVE-2019-19135

In OPC Foundation OPC UA .NET Standard codebase 1.4.357.28, servers do not create sufficiently random numbers in OPCFoundation.NetStandard.Opc.Ua before 1.4.359.31, which allows man in the middle attackers to reuse encrypted user credentials sent over the network...

7.4CVSS7.4AI score0.01043EPSS
SaveExploits0References2
OSV
OSV
added 2020/03/16 4:15 p.m.11 views

CVE-2019-19135

In OPC Foundation OPC UA .NET Standard codebase 1.4.357.28, servers do not create sufficiently random numbers in OPCFoundation.NetStandard.Opc.Ua before 1.4.359.31, which allows man in the middle attackers to reuse encrypted user credentials sent over the network...

7.4CVSS6.8AI score
SaveExploits0References2
Prion
Prion
added 2020/03/16 4:15 p.m.15 views

Code injection

In OPC Foundation OPC UA .NET Standard codebase 1.4.357.28, servers do not create sufficiently random numbers in OPCFoundation.NetStandard.Opc.Ua before 1.4.359.31, which allows man in the middle attackers to reuse encrypted user credentials sent over the network...

5.8CVSS7.3AI score0.01043EPSS
SaveExploits0References2Affected Software2
Cvelist
Cvelist
added 2020/03/16 3:47 p.m.36 views

CVE-2019-19135

In OPC Foundation OPC UA .NET Standard codebase 1.4.357.28, servers do not create sufficiently random numbers in OPCFoundation.NetStandard.Opc.Ua before 1.4.359.31, which allows man in the middle attackers to reuse encrypted user credentials sent over the network...

7.3AI score0.01043EPSS
SaveExploits0References2
CVE
CVE
added 2020/03/16 3:47 p.m.83 views

CVE-2019-19135

CVE-2019-19135 concerns the OPC Foundation OPC UA .NET Standard stack (version 1.4.357.28) where servers do not generate sufficiently random numbers before 1.4.359.31. This weakness can allow a remote attacker to perform a MITM and reuse encrypted user credentials sent over the network. Public do...

7.4CVSS7.3AI score0.01043EPSS
SaveExploits0References2Affected Software2
ThreatPost
ThreatPost
added 2020/01/22 11:50 p.m.73 views

Pwn2Own Miami Contestants Haul in $180K for Hacking ICS Equipment

The very first Pwn2Own hacking competition that exclusively focuses on the industrial control systems ICS has kicked off in Miami. So far, a total of $180,000 has been awarded for pwning five different products. The contest hosts at Trend Micro’s Zero Day initiative ZDI have allocated more than...

1.9AI score
SaveExploits0References6
OSV
OSV
added 2020/01/17 2:15 a.m.6 views

CVE-2019-19802

In Gallagher Command Centre Server v8.10 prior to v8.10.1134MR4, v8.00 prior to v8.00.1161MR5, v7.90 prior to v7.90.991MR5, v7.80 prior to v7.80.960MR2 and v7.70 or earlier, an authenticated user connecting to OPCUA can view all data that would be replicated in a multi-server setup without...

6.5CVSS5.8AI score0.00752EPSS
SaveExploits0References1
Pen Test Partners Blog
Pen Test Partners Blog
added 2019/12/03 12:18 p.m.61 views

Analysing the Attack Surface of an Industrial Data Acquisition Device

Introduction The Data Station Plus from Red Lion Controls was handed to me to analyse the attack surface. The device is designed to connect to SCADA data acquisition devices over Modbus, Profibus, etc. by Serial or Ethernet connection. Data is collected and recorded to a local compact flash card...

7.1AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.29 views

Siemens Simatic Improper Input Validation

A vulnerability has been identified in SIMATIC CP 443-1 OPC UA All versions, SIMATIC CP443-1 OPC UA incl. SIPLUS NET variants All versions, SIMATIC ET 200 Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions = V7.1 = V2.5 V2.6.1, SIMATIC S7-1500 Software Controller All versions betwe...

7.8CVSS1.7AI score0.01633EPSS
SaveExploits0References2
OSV
OSV
added 2019/09/17 7:15 p.m.5 views

CVE-2019-13542

3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition...

6.5CVSS6.9AI score0.01365EPSS
SaveExploits0References1
NVD
NVD
added 2019/09/17 7:15 p.m.26 views

CVE-2019-13542

3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition...

6.5CVSS6.4AI score0.01365EPSS
SaveExploits0References1
Prion
Prion
added 2019/09/17 7:15 p.m.16 views

Null pointer dereference

3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition...

4CVSS6.3AI score0.01365EPSS
SaveExploits0References1Affected Software10
CVE
CVE
added 2019/09/17 6:56 p.m.105 views

CVE-2019-13542

CVE-2019-13542 affects 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server (versions 3.5.11.0 to 3.5.15.0). The vulnerability is a NULL pointer dereference triggered by crafted requests from a trusted OPC UA client, potentially causing a denial-of-service condition. Public sources (CISA ICS...

6.5CVSS6.3AI score0.01365EPSS
SaveExploits0References1Affected Software10
Cvelist
Cvelist
added 2019/09/17 6:56 p.m.33 views

CVE-2019-13542

3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition...

6.4AI score0.01365EPSS
SaveExploits0References1
ICS
ICS
added 2019/09/12 12:0 a.m.111 views

3S-Smart Software Solutions GmbH CODESYS Control V3 OPC UA Server

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: 3S-Smart Software Solutions GmbH Equipment: CODESYS Control V3 OPC UA Server Vulnerability: NULL Pointer Reference 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a...

6.5CVSS6.6AI score0.01365EPSS
SaveExploits0References4
ICS
ICS
added 2019/09/10 12:0 a.m.532 views

ICSA-19-253-03_Siemens Industrial Products (Update P)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Products Vulnerabilities: Excessive Data Query Operations in a Large Data Table, Integer Overflow or Wraparound, Uncontrolled Resource Consumption 2. UPDATE INFORMATION...

8.6AI score
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.12 views

Schneider Electric OPC Factory Server (OFS) HMI Detection

Binary data 761524.prm...

7.3AI score
SaveExploits0
Rows per page