1314 matches found
Design/Logic Flaw
Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data...
CVE-2022-2967
Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data...
CVE-2022-2967
Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data...
CVE-2022-2967
Summary: CVE-2022-2967 affects Prosys OPC UA Simulation Server and UA Modbus Server. The root cause is insufficient protection of credentials, allowing an attacker to obtain user credentials and access system data. Affected products/versions: Prosys OPC UA Simulation Server before 5.3.0-64 and UA...
PT-2023-12985 · Prosyst · Prosys Opc Ua Simulation Server
Name of the Vulnerable Software and Affected Versions: Prosys OPC UA Simulation Server versions prior to 5.3.0-64 UA Modbus Server versions 1.4.18-5 and prior Description: The issue concerns insufficient protection of credentials, potentially allowing an attacker to obtain user credentials and ga...
CISA Releases Six Industrial Control Systems Advisories
CISA released six Industrial Control Systems ICS advisories on December 20, 2022. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories for...
Prosys OPC UA Simulation Server (Update A)
1. EXECUTIVE SUMMARY CVSS v3 6.5 --------- Begin Update A part 1 of 3 --------- ATTENTION: Low attack complexity Vendor: Prosys OPC Equipment: UA Simulation Server, UA Modbus Server --------- End Update A part 1 of 3 --------- Vulnerability: Insufficiently Protected Credentials 2. UPDATE...
Mitsubishi Electric FA Engineering Software (Update C)
1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: GX Works3, MX OPC UA Module Configurator-R Vulnerabilities: Cleartext Storage of Sensitive Information, Use of Hard-coded Password, Insufficiently Protected Credentials,...
The vulnerability of implementations of OPC Classic standards in network interfaces of Tofino Xenon Security Appliance, Tofino Argon Security Appliance, and EAGLE 20 Tofino allows attackers to circumvent existing security restrictions.
The vulnerability of OPC Classic standard implementations in network interfaces of Tofino Xenon Security Appliance, Tofino Argon Security Appliance, and EAGLE 20 Tofino is related to security configuration errors. Exploiting this vulnerability allows a malicious actor to circumvent existing...
CVE-2022-25164
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
CVE-2022-25164
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
Information disclosure
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
CVE-2022-25164
CVE-2022-25164 is a cleartext storage vulnerability affecting Mitsubishi Electric GX Works3 (versions 1.000A–1.095Z) and MX OPC UA Module Configurator-R (1.08J and earlier). Root cause: sensitive data stored in cleartext, enabling remote, unauthenticated disclosure and potential access to MELSEC ...
CVE-2022-25164
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
CVE-2022-44725
OPC Foundation Local Discovery Server LDS through 1.04.403.478 uses a hard-coded file path to a configuration file. This allows a normal user to create a malicious file that is loaded by LDS running as a high-privilege user...
CVE-2022-44725
OPC Foundation Local Discovery Server LDS through 1.04.403.478 uses a hard-coded file path to a configuration file. This allows a normal user to create a malicious file that is loaded by LDS running as a high-privilege user...
Design/Logic Flaw
OPC Foundation Local Discovery Server LDS through 1.04.403.478 uses a hard-coded file path to a configuration file. This allows a normal user to create a malicious file that is loaded by LDS running as a high-privilege user...
CVE-2022-44725
Summary (CVE-2022-44725): OPC Foundation Local Discovery Server (LDS) vulnerability affecting Siemens/OpenPCS/Siemens SIMATIC components (e.g., OpenPCS 7 V9.1, SIMATIC NET PC Software V14–V18, SIMATIC WinCC Runtime Professional/Unified PC Runtime, TeleControl Server Basic V3, etc.). Root cause: L...
CVE-2022-44725
OPC Foundation Local Discovery Server LDS through 1.04.403.478 uses a hard-coded file path to a configuration file. This allows a normal user to create a malicious file that is loaded by LDS running as a high-privilege user...