499 matches found
CVE-2022-29604
ONOS 2.5.1 is affected: an intent with an uppercase device ID can enter a CORRUPT state due to case-sensitivity mishandling, causing inconsistency between intent and flow rules. The connected documents reiterate the issue but do not provide a concrete fix or remediation details. No further exploi...
CVE-2022-29609: Always-Incorrect Control Flow Implementation
An issue was discovered in ONOS 2.5.1. An intent with the same source and destination shows the INSTALLING state, indicating that its flow rules are installing. Improper handling of such an intent is misleading to a network operator...
CVE-2022-29605
CVE-2022-29605 affects ONOS 2.5.1. The issue arises in the IntentManager , which attempts to install IPv6 flow rules for an intent into an OpenFlow 1.0 switch that does not support IPv6, due to improper handling of the capabilities mismatch. This discrepancy can mislead network operators about th...
CVE-2022-29607
CVE-2022-29607 affects ONOS 2.5.1. The issue arises when modifying an existing intent to have the same source and destination, which causes the system to show the INSTALLED state even though no flow rule is installed. The description indicates this can mislead a network operator. No specific expl...
CVE-2022-24109
An issue was discovered in ONOS 2.5.1. To attack an intent installed by a normal user, a remote attacker can install a duplicate intent with a different key, and then remove the duplicate one. This will remove the flow rules of the intent, even though the intent still exists in the controller...
CVE-2022-29607: Always-Incorrect Control Flow Implementation
An issue was discovered in ONOS 2.5.1. Modification of an existing intent to have the same source and destination shows the INSTALLED state without any flow rule. Improper handling of such an intent is misleading to a network operator...
CVE-2022-29605: Always-Incorrect Control Flow Implementation
An issue was discovered in ONOS 2.5.1. IntentManager attempts to install the IPv6 flow rules of an intent into an OpenFlow 1.0 switch that does not support IPv6. Improper handling of the difference in capabilities of the intent and switch is misleading to a network operator...
CVE-2022-24109: Uncontrolled Resource Consumption
An issue was discovered in ONOS 2.5.1. To attack an intent installed by a normal user, a remote attacker can install a duplicate intent with a different key, and then remove the duplicate one. This will remove the flow rules of the intent, even though the intent still exists in the controller...
CVE-2022-24035: Uncontrolled Resource Consumption
An issue was discovered in ONOS 2.5.1. The purge-requested intent remains on the list, but it does not respond to changes in topology e.g., link failure. In combination with other applications, it could lead to a failure of network management...
CVE-2022-29608
CVE-2022-29608 affects ONOS 2.5.1. The issue arises when an intent uses a port that is an intermediate point in its path, which results in the installation of an invalid flow rule and can create a network loop. The available connected documents confirm the affected software and the underlying beh...
CVE-2022-24109
The CVE-2022-24109 entry concerns the Open Networking Foundation ONOS 2.5.1. An attacker can install a duplicate intent (with a different key) for an intent installed by a normal user, then remove the duplicate; this action removes the flow rules of the original intent even though the intent rema...
CVE-2022-29608
An issue was discovered in ONOS 2.5.1. An intent with a port that is an intermediate point of its path installs an invalid flow rule, causing a network loop...
CVE-2022-24035
An issue was discovered in ONOS 2.5.1. The purge-requested intent remains on the list, but it does not respond to changes in topology e.g., link failure. In combination with other applications, it could lead to a failure of network management...
CVE-2022-29944: Incorrect Comparison
An issue was discovered in ONOS 2.5.1. There is an incorrect comparison of paths installed by intents. An existing intents does not redirect to a new path, even if a new intent that shares the path with higher priority is installed...
CVE-2022-29606: Improper Input Validation
An issue was discovered in ONOS 2.5.1. An intent with a large port number shows the CORRUPT state, which is misleading to a network operator. Improper handling of such port numbers causes inconsistency between intent and flow rules in the network...
CVE-2022-29604: Improper Handling of Case Sensitivity
An issue was discovered in ONOS 2.5.1. An intent with an uppercase letter in a device ID shows the CORRUPT state, which is misleading to a network operator. Improper handling of case sensitivity causes inconsistency between intent and flow rules in the network...
CVE-2021-38363
An issue was discovered in ONOS 2.5.1. In IntentManager, the install-requested intent which causes an exception remains in pendingMap in memory forever. Deletion is possible neither by a user nor by the intermittent Intent Cleanup process...
CVE-2022-29606
ONOS 2.5.1 contains a vulnerability where an intent with large port numbers can enter a CORRUPT state, creating inconsistency between the declared intent and the resulting flow rules. Affected component is the intent handling/validation logic within the ONOS controller’s intent framework. The iss...
CVE-2022-29609
An issue was discovered in ONOS 2.5.1. An intent with the same source and destination shows the INSTALLING state, indicating that its flow rules are installing. Improper handling of such an intent is misleading to a network operator...
PT-2023-12981 · Onos · Onos
Name of the Vulnerable Software and Affected Versions: ONOS version 2.5.1 Description: An issue was discovered where an intent with a large port number shows the CORRUPT state, which is misleading to a network operator. Improper handling of such port numbers causes inconsistency between intent an...