11 matches found
CVE-2025-40944
A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN 6ES7157-1AB00-0AB0 All versions, SIMATIC ET 200MP IM 155-5 PN HF 6ES7155-5AA00-0AC0 All versions = V4.2.0, SIMATIC ET 200SP IM 155-6 MF HF 6ES7155-6MU00-0CN0 All versions, SIMATIC ET 200SP IM 155-6 PN HA incl. SIPLUS variants All...
CVE-2023-29533
A website could have obscured the fullscreen notification by using a combination of window.open, fullscreen requests, window.name assignments, and setInterval calls. This could have led to user confusion and possible spoofing attacks. This vulnerability affects Firefox 112, Focus for Android 112,...
Mozilla: Memory safety bugs fixed in Firefox 105 and Firefox ESR 102.3
A flaw was found in Mozilla. The Mozilla Foundation Security Advisory describes the issue of Mozilla developers Nika Layzell, Timothy Nikkel, Jeff Muizelaar, Sebastian Hengst, Andreas Pehrson, and the Mozilla Fuzzing Team reporting memory safety bugs present in Firefox 104 and Firefox ESR 102.2...
Mozilla: Memory safety bugs fixed in Firefox 104, Firefox ESR 102.2, and Firefox ESR 91.13
A flaw was found in Mozilla. The Mozilla Foundation Security Advisory describes the issue of members on the Mozilla Fuzzing Team reporting memory safety bugs present in Firefox 103, Firefox ESR 102.1, and Firefox ESR 91.12. Some of these bugs showed evidence of memory corruption, and we presume...
PT-2020-14628 · Siemens · Sinumerik 840D Sl +2
Name of the Vulnerable Software and Affected Versions: SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions SIMATIC TDC CPU555 All versions SINUMERIK 840D sl All versions Description: A Denial-of-Service issue has been identified, which can be triggered by sending...
The vulnerability of microprogrammed software in Siemens Simatic S7-400 programmable logic controllers is related to errors in checking input data by Ethernet, PROFIBUS, and MPI interfaces. This allows a malicious actor to trigger a service failure.
The vulnerability of microprogrammed programmable logic controllers from Siemens Simatic S7-400 is related to errors in the validation of input data by Ethernet, PROFIBUS, and MPI interfaces. Exploiting this vulnerability can allow an attacker to cause maintenance failures by sending a specially...
The vulnerability of microprogrammed software in Siemens Simatic S7-1200 programmable logic controllers arises from the exceeding of specified resource limits. This allows a malicious entity to exhaust available network connections and cause failures in the device’s network communication capabilities.
The vulnerability of Siemens Simatic S7-1200 programmable logic controllers’ microprogramming software is related to the overuse of resources. Exploiting this vulnerability can allow an attacker to exhaust available network connections and cause failures in the device’s network communication by...
Siemens TIM 1531 IRC Authentication Vulnerability
The Siemens TIM 1531 IRC is a communication module from Siemens, Germany. A security vulnerability exists in the Siemens TIM 1531 IRC prior to version 2.0, which originates from the device failing to properly authenticate itself when connecting on port 102/tcp. An attacker could use this...
CVE-2018-11452
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...
The vulnerability of the microprogramming software of Siemens Simatic S7-1200 programmable logic controllers allows a malicious actor to cause malfunctions during maintenance operations.
The software of the Siemens SIMATIC S7-1200 programmable logic controller contains a vulnerability. When this vulnerability is exploited, the device can be switched into an emergency mode by sending a special TCP/IP packet to port 102. This emergency mode persists until a hardware restart is...
Siemens SIMATIC STEP 7 TIA Portal Man-in-the-Middle Attack Information Disclosure Vulnerability
Siemens SIMATIC is an automation software with a single engineering environment. A man-in-the-middle attack vulnerability exists in Siemens SIMATIC STEP 7 TCP port 102, which could be exploited by an attacker to intercept or modify communications...