Lucene search
+L

260 matches found

Prion
Prion
added 2018/03/05 5:29 p.m.16 views

Input validation

An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable...

7.8CVSS7.8AI score0.01205EPSS
SaveExploits0References1Affected Software4
OSV
OSV
added 2018/03/05 5:29 p.m.6 views

CVE-2018-5453

An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable...

7.5CVSS5.8AI score0.01205EPSS
SaveExploits0References1
CVE
CVE
added 2018/03/05 5:0 p.m.52 views

CVE-2018-5455

The CVE-2018-5455 vulnerability affects Moxa OnCell G3100-HSPA Series (version 1.4 Build 16062919 and earlier). It stems from reliance on cookies without validation or integrity checking, allowing a cookie parameter consisting only of digits to be brute-forced, bypassing authentication and enabli...

9.8CVSS9.3AI score0.01591EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2018/03/05 5:0 p.m.27 views

CVE-2018-5449

A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack...

6.3AI score0.00493EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2018/03/05 5:0 p.m.21 views

CVE-2018-5453

An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable...

7.4AI score0.01205EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2018/03/05 5:0 p.m.20 views

CVE-2018-5455

A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing...

9.5AI score0.01591EPSS
SaveExploits0References1
CVE
CVE
added 2018/03/05 5:0 p.m.49 views

CVE-2018-5449

CVE-2018-5449 affects Moxa OnCell G3100-HSPA Series (version 1.4 Build 16062919 and prior). Root cause: application does not check for NULL values, causing a NULL pointer dereference that leads to denial of service. Affected component: the device application. Impact per sources: CVSS v3 base 6.5 ...

6.5CVSS6.3AI score0.00493EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2018/03/05 5:0 p.m.48 views

CVE-2018-5453

CVE-2018-5453 affects the Moxa OnCell G3100-HSPA Series (version 1.4 Build 16062919 and prior). The vulnerability is described as an improper handling of length parameter inconsistency, allowing an attacker to edit an element of an HTTP request and potentially render the device unavailable. The N...

7.8CVSS7.3AI score0.01205EPSS
SaveExploits0References1Affected Software1
CNVD
CNVD
added 2018/03/02 12:0 a.m.6 views

Moxa OnCell G3100-HSPA Series Denial of Service Vulnerability

The Moxa OnCell G3100-HSPA is an intelligent, feature-rich wireless communications platform that enables networked and serial devices to connect to cellular TCP/IP networks. A denial of service vulnerability exists in the Moxa OnCell G3100-HSPA Series, which can be exploited by an attacker to edi...

7.8CVSS6.8AI score0.01205EPSS
SaveExploits0References1
CNVD
CNVD
added 2018/03/02 12:0 a.m.6 views

Moxa OnCell G3100-HSPA Series Authentication Bypass Vulnerability

The Moxa OnCell G3100-HSPA is an intelligent, feature-rich wireless communications platform that enables networked and serial devices to connect to cellular TCP/IP networks. An authentication bypass vulnerability exists in the Moxa OnCell G3100-HSPA Series that stems from an application allowing...

9.8CVSS7.3AI score0.01591EPSS
SaveExploits0References1
CNVD
CNVD
added 2018/03/02 12:0 a.m.5 views

Moxa OnCell G3100-HSPA Series Null Pointer Reference Denial of Service Vulnerability

The Moxa OnCell G3100-HSPA is an intelligent, feature-rich wireless communications platform that enables networked and serial devices to connect to cellular TCP/IP networks. A null pointer reference denial of service vulnerability exists in the Moxa OnCell G3100-HSPA Series, which stems from an...

6.5CVSS6.8AI score0.00493EPSS
SaveExploits0References1
ICS
ICS
added 2018/03/01 12:0 a.m.66 views

Moxa OnCell G3100-HSPA Series

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Moxa Equipment: OnCell G3100-HSPA Series Vulnerabilities: Reliance on Cookies without Validation and Integrity Checking, Improper Handling of Length Parameter Inconsistency, NULL Pointer Dereference AFFECTED PRODUCTS...

9.8CVSS8.5AI score0.01591EPSS
SaveExploits0References5
CNVD
CNVD
added 2017/06/02 12:0 a.m.6 views

Cross-Site Request Forgery Vulnerability in Multiple Moxa Products

Moxa OnCell G3110-HSPA and so on are products of China Moxa Moxa, of which OnCell G3110-HSPA is an industrial-grade IP gateway and OnCell 5104-HSPA is an industrial-grade cellular router. A cross-site request forgery vulnerability exists in multiple Moxa products that stems from a program failing...

8.8CVSS7AI score0.00494EPSS
SaveExploits0References1
CNVD
CNVD
added 2017/06/02 12:0 a.m.6 views

Brute-force vulnerability in multiple Moxa products

Moxa OnCell G3110-HSPA and so on are products of China Moxa Moxa, of which OnCell G3110-HSPA is an industrial-grade IP gateway and OnCell 5104-HSPA is an industrial-grade cellular router. A brute force vulnerability exists in multiple Moxa products. An attacker could exploit this vulnerability to...

9.8CVSS6.9AI score0.01532EPSS
SaveExploits0References1
NVD
NVD
added 2017/05/29 4:29 p.m.19 views

CVE-2017-7913

A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell...

9.8CVSS9.5AI score0.01179EPSS
SaveExploits0References1
OSV
OSV
added 2017/05/29 4:29 p.m.6 views

CVE-2017-7917

A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell...

8.8CVSS5.8AI score0.00494EPSS
SaveExploits0References1
NVD
NVD
added 2017/05/29 4:29 p.m.20 views

CVE-2017-7915

An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions,...

9.8CVSS9.6AI score0.01532EPSS
SaveExploits0References1
Prion
Prion
added 2017/05/29 4:29 p.m.22 views

Authentication flaw

An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions,...

7.5CVSS9.4AI score0.01532EPSS
SaveExploits0References1Affected Software3
OSV
OSV
added 2017/05/29 4:29 p.m.7 views

CVE-2017-7913

A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell...

9.8CVSS5.8AI score0.01179EPSS
SaveExploits0References1
NVD
NVD
added 2017/05/29 4:29 p.m.19 views

CVE-2017-7917

A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell...

8.8CVSS9AI score0.00494EPSS
SaveExploits0References1
Rows per page