294 matches found
CVE-2024-31854
A vulnerability has been identified in SICAM TOOLBOX II All versions V07.11. During establishment of a https connection to the TLS server of a managed device, the affected application doesn't check device's certificate common name against an expected value. This could allow an attacker to execute...
Siemens SIPROTEC and SICAM
SUMMARY This advisory documents the impact of CVE-2024-3596 also dubbed "Blastradius", a vulnerability in the RADIUS protocol, to SIPROTEC, SICAM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server the RADIUS client, e.g., a SICAM device...
CVE-2025-20126: Improper Certificate Validation
A vulnerability in certification validation routines of Cisco ThousandEyes Endpoint Agent for macOS and RoomOS could allow an unauthenticated, remote attacker to intercept or manipulate metrics information. This vulnerability exists because the affected software does not properly validate...
CVE-2024-41681
A vulnerability has been identified in Location Intelligence family All versions V4.4. The web server of affected products is configured to support weak ciphers by default. This could allow an unauthenticated attacker in an on-path position to to read and modify any data passed over the connectio...
CVE-2024-41681
A vulnerability has been identified in Location Intelligence family All versions V4.4. The web server of affected products is configured to support weak ciphers by default. This could allow an unauthenticated attacker in an on-path position to to read and modify any data passed over the connectio...
PT-2024-7640 · Unknown · Location Intelligence
Name of the Vulnerable Software and Affected Versions: Location Intelligence versions prior to V4.4 Description: The issue is related to insufficiently strong data encryption. This could allow an unauthenticated attacker in an on-path position to read and modify any data passed over the connectio...
CVE-2024-41681: Inadequate Encryption Strength
A vulnerability has been identified in Location Intelligence family All versions V4.4. The web server of affected products is configured to support weak ciphers by default. This could allow an unauthenticated attacker in an on-path position to to read and modify any data passed over the connectio...
CVE-2024-5631
Longse NVR Network Video Recorder model NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the...
CVE-2024-5631
Summary (verified by provided sources): CVE-2024-5631 affects Longse LBH30FE200W cameras and related devices (e.g., NVR3608PGE2W family). The issue enables credential exposure because login/password are transmitted to a remote control service without encryption when a user changes their password,...
Siemens SCALANCE, RUGGEDCOM, SIPLUS, and SINEC
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
K17663061: BIG-IP SSL state mirroring vulnerability CVE-2020-5885
Security Advisory Description BIG-IP systems set up for connection mirroring in a high availability HA pair transfer sensitive cryptographic objects over an insecure communications channel. This is a control plane issue which is exposed only on the network used for connection mirroring...
K65720640: BIG-IP SSL state mirroring vulnerability CVE-2020-5886
Security Advisory Description BIG-IP systems setup for connection mirroring in a High Availability HA pair transfers sensitive cryptographic objects over an insecure communications channel. This is a control plane issue which is exposed only on the network used for connection mirroring...
K72540690: BIG-IP high availability state mirroring vulnerability CVE-2020-5884
Security Advisory Description The default deployment mode for BIG-IP high availability HA pair mirroring is insecure. This is a control plane issue that is exposed only on the network used for mirroring. CVE-2020-5884 Impact On-path attackers may be able to read and modify data in transit...
SUSE CVE-2019-6475
Mirror zones are a BIND feature allowing recursive servers to pre-cache zone data provided by other servers. A mirror zone is similar to a zone of type secondary, except that its data is subject to DNSSEC validation before being used in answers, as if it had been looked up via traditional...
Dovecot 2.3.0 - 2.3.14 Information Disclosure Vulnerability
Dovecot is prone to an information disclosure vulnerability. Copyright C 2021 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This program is free software;...
Command Injection
dovecot is vulnerable to command injection. On-path attacker could inject plaintext commands before STARTTLS negotiation that would be executed after STARTTLS finished with the client. Only the SMTP submission service is affected...
CVE-2020-26230
Radar COVID is the official COVID-19 exposure notification app for Spain. In affected versions of Radar COVID, identification and de-anonymization of COVID-19 positive users that upload Radar COVID TEKs to the Radar COVID server is possible. This vulnerability enables the identification and...
CVE-2020-26230: Exposure of Sensitive Information to an Unauthorized Actor
Radar COVID is the official COVID-19 exposure notification app for Spain. In affected versions of Radar COVID, identification and de-anonymization of COVID-19 positive users that upload Radar COVID TEKs to the Radar COVID server is possible. This vulnerability enables the identification and...
PT-2020-16359
Name of the Vulnerable Software and Affected Versions Radar COVID versions prior to 1.0.8 uniform distribution and 1.1.0 exponential distribution on iOS Radar COVID versions prior to 1.0.7 uniform distribution and 1.1.0 exponential distribution on Android Radar COVID Backend versions prior to...
F5 Networks BIG-IP : BIG-IP SSL state mirroring vulnerability (K17663061)
BIG-IP systems set up for connection mirroring in a high availability HA pair transfersensitive cryptographic objects over an insecure communications channel. This is a control plane issue which is exposed only on the network used for connection mirroring.CVE-2020-5885 Impact On-path attackers ma...