111 matches found
CVE-2011-20002
Affected software/hardware: Siemens SIMATIC S7-1200 CPU V1/V2 families (incl. SIPLUS variants). Vulnerability: Capture-replay of engineering software communication that can allow an on-path attacker to replay legitimate commands to the controller. Root cause (from sources): Insecure handling of e...
EUVD-2011-5261
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family incl. SIPLUS variants All versions V2.0.2, SIMATIC S7-1200 CPU V2 family incl. SIPLUS variants All versions V2.0.2. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This...
CVE-2011-20002
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family incl. SIPLUS variants All versions V2.0.2, SIMATIC S7-1200 CPU V2 family incl. SIPLUS variants All versions V2.0.2. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This...
CVE-2011-20002
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family incl. SIPLUS variants All versions V2.0.2, SIMATIC S7-1200 CPU V2 family incl. SIPLUS variants All versions V2.0.2. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This...
EUVD-2024-34087
Malicious code in bioql PyPI...
EUVD-2024-29723
Malicious code in bioql PyPI...
CVE-2024-31854
A vulnerability has been identified in SICAM TOOLBOX II All versions V07.11. During establishment of a https connection to the TLS server of a managed device, the affected application doesn't check device's certificate common name against an expected value. This could allow an attacker to execute...
Siemens SIPROTEC and SICAM
SUMMARY This advisory documents the impact of CVE-2024-3596 also dubbed "Blastradius", a vulnerability in the RADIUS protocol, to SIPROTEC, SICAM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server the RADIUS client, e.g., a SICAM device...
CVE-2024-41681
A vulnerability has been identified in Location Intelligence family All versions V4.4. The web server of affected products is configured to support weak ciphers by default. This could allow an unauthenticated attacker in an on-path position to to read and modify any data passed over the connectio...
CVE-2024-41681
A vulnerability has been identified in Location Intelligence family All versions V4.4. The web server of affected products is configured to support weak ciphers by default. This could allow an unauthenticated attacker in an on-path position to to read and modify any data passed over the connectio...
PT-2024-7640 · Unknown · Location Intelligence
Name of the Vulnerable Software and Affected Versions: Location Intelligence versions prior to V4.4 Description: The issue is related to insufficiently strong data encryption. This could allow an unauthenticated attacker in an on-path position to read and modify any data passed over the connectio...
CVE-2024-5631
Longse NVR Network Video Recorder model NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the...
CVE-2024-5631
Summary (verified by provided sources): CVE-2024-5631 affects Longse LBH30FE200W cameras and related devices (e.g., NVR3608PGE2W family). The issue enables credential exposure because login/password are transmitted to a remote control service without encryption when a user changes their password,...
Siemens SCALANCE, RUGGEDCOM, SIPLUS, and SINEC
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
K17663061: BIG-IP SSL state mirroring vulnerability CVE-2020-5885
Security Advisory Description BIG-IP systems set up for connection mirroring in a high availability HA pair transfer sensitive cryptographic objects over an insecure communications channel. This is a control plane issue which is exposed only on the network used for connection mirroring...
K65720640: BIG-IP SSL state mirroring vulnerability CVE-2020-5886
Security Advisory Description BIG-IP systems setup for connection mirroring in a High Availability HA pair transfers sensitive cryptographic objects over an insecure communications channel. This is a control plane issue which is exposed only on the network used for connection mirroring...
K72540690: BIG-IP high availability state mirroring vulnerability CVE-2020-5884
Security Advisory Description The default deployment mode for BIG-IP high availability HA pair mirroring is insecure. This is a control plane issue that is exposed only on the network used for mirroring. CVE-2020-5884 Impact On-path attackers may be able to read and modify data in transit...
SUSE CVE-2019-6475
Mirror zones are a BIND feature allowing recursive servers to pre-cache zone data provided by other servers. A mirror zone is similar to a zone of type secondary, except that its data is subject to DNSSEC validation before being used in answers, as if it had been looked up via traditional...
Dovecot 2.3.0 - 2.3.14 Information Disclosure Vulnerability
Dovecot is prone to an information disclosure vulnerability. Copyright C 2021 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This program is free software;...
Command Injection
dovecot is vulnerable to command injection. On-path attacker could inject plaintext commands before STARTTLS negotiation that would be executed after STARTTLS finished with the client. Only the SMTP submission service is affected...