EUVD-2022-48646
Malicious code in bioql PyPI...
CVE-2022-45790
The Omron FINS protocol has an authenticated feature to prevent access to memory regions. Authentication is susceptible to bruteforce attack, which may allow an adversary to gain access to protected memory. This access can allow overwrite of values including programmed logic...
CVE-2022-45790
The Omron FINS protocol has an authenticated feature to prevent access to memory regions. Authentication is susceptible to bruteforce attack, which may allow an adversary to gain access to protected memory. This access can allow overwrite of values including programmed logic...
Authentication flaw
The Omron FINS protocol has an authenticated feature to prevent access to memory regions. Authentication is susceptible to bruteforce attack, which may allow an adversary to gain access to protected memory. This access can allow overwrite of values including programmed logic...
CVE-2022-45790 Omron FINS memory protection susceptible to bruteforce
The Omron FINS protocol has an authenticated feature to prevent access to memory regions. Authentication is susceptible to bruteforce attack, which may allow an adversary to gain access to protected memory. This access can allow overwrite of values including programmed logic...
CVE-2022-45790
The CVE-2022-45790 issue concerns Omron FINS protocol memory protection with an authenticated access mechanism that is susceptible to brute-force guessing. Connected sources identify affected Omron CJ/CS/CP-series PLCs (and related components) using FINS to access password-protected memory region...
CVE-2022-31204
Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations such as project/logic uploads and downloads. This...
CVE-2022-31204
Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations such as project/logic uploads and downloads. This...
OMRON FINS TCP Protocol Detection
Binary data scadaomrontcpdetect.nbin...
OMRON FINS UDP Protocol Detection
Binary data scadaomronudpdetect.nbin...
omron-info NSE Script
This NSE script is used to send a FINS packet to a remote device. The script will send a Controller Data Read Command and once a response is received, it validates that it was a proper response to the command that was sent, and then will parse out the data. Example Usage nmap --script omron-info...