16 matches found
EUVD-2019-16137
Malware in sbrugna...
CVE-2023-25200
An HTML injection vulnerability exists in the MT Safeline X-Ray X3310 webserver version NXG 19.05 that enables a remote attacker to render malicious HTML and obtain sensitive information in a victim's browser...
CVE-2023-25200
An HTML injection vulnerability exists in the MT Safeline X-Ray X3310 webserver version NXG 19.05 that enables a remote attacker to render malicious HTML and obtain sensitive information in a victim's browser...
CVE-2023-25200
The CVE-2023-25200 entry concerns MT Safeline X-Ray X3310 Webserver NXG 19.05 with an HTML injection vulnerability that can cause a remote attacker to render malicious HTML in a victim's browser and access sensitive information. Red Hat and other sources describe it as an HTML injection/XSS issue...
CVE-2023-25199
A reflected cross-site scripting XSS vulnerability exists in the MT Safeline X-Ray X3310 webserver version NXG 19.05 that enables a remote attacker to execute JavaScript code and obtain sensitive information in a victim's browser...
CVE-2023-25199
CVE-2023-25199 is a reflected XSS vulnerability in MT Safeline X-Ray X3310 webserver (NXG 19.05). The Red Hat entries describe a reflected XSS; other sources confirm the same affected version. The vulnerability allows a remote attacker to execute JavaScript in a victim’s browser and access sensit...
CVE-2023-25200
An HTML injection vulnerability exists in the MT Safeline X-Ray X3310 webserver version NXG 19.05 that enables a remote attacker to render malicious HTML and obtain sensitive information in a victim's browser...
PT-2023-2620 · Nexx · Nexx Smart Alarm +2
Name of the Vulnerable Software and Affected Versions: Nexx Garage Door Controller versions NXG-100B, NXG-200 Nexx Smart Plug version NXPG-100W Nexx Smart Alarm version NXAL-100 Description: The issue is related to a lack of proper access control when executing actions on Nexx Smart Home devices...
CVE-2019-6578
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28. A denial of service...
CVE-2019-6574
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...
Code injection
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...
Denial of service
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28. A denial of service...
CVE-2019-6574
CVE-2019-6574 affects Siemens SINAMICS PERFECT HARMONY GH180 (NXG I/NXG II) with MLFBs 6SR2...-, 6SR3...-, 6SR4...- (options G21–G46). Root cause: improperly configured Parameter Read/Write execution via Fieldbus network, enabling a remote attacker with network access to restart the controller an...
CVE-2019-6574
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...
CVE-2019-6578
CVE-2019-6578 affects Siemens SINAMICS PERFECT HARMONY GH180 drives (NXG I/II) with option G28, where an attacker with network access can trigger a denial-of-service via uncontrolled resource consumption on the Ethernet Modbus interface. No privileges or user interaction are required; impact is a...
ICSA-19-134-05 Siemens SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could...