Kitploit
Kitploit
•added 2026/09/24 3:05 p.m.•15 views

CVE-2026-9789

CVE ID: CVE-2026-9789 研究者: Vo Duc Thang ugvxb 謝辞: https://community.acer.com/en/kb/articles/19670 PoC動画: https://drive.google.com/file/d/1B8b42bE68CWMnlqG6eJWi0txGFsHAJZc/view?usp=sharing 1. エグゼクティブサマリー エイサー NitroSense ソフトウェア PSAdminAgent.exe に、重大なローカル権限昇格の脆弱性が発見されました。この脆弱性により、認証されたローカルユーザーが...

8.5CVSS5.9AI score0.00146EPSS
SaveExploits1
NVD
NVD
•added 2026/09/23 8:17 a.m.•10 views

CVE-2026-50228

An unauthenticated local attacker can connect to the Electron DevTools endpoint exposed by Acer NitroSense software versions up to and including 5.2.63 on localhost TCP port 9993. Because Chromium remote debugging is enabled in the production application, the attacker can execute JavaScript in th...

8.6CVSS0.00134EPSS
SaveExploits0References1
NVD
NVD
•added 2026/09/23 8:17 a.m.•12 views

CVE-2026-50227

An unauthenticated local attacker can connect to the MQTT broker over its localhost WebSocket endpoint in Acer NitroSense software versions up to and including 5.2.62. This allows the attacker to invoke exposed ddsc RPC functions, including childprocess.execSync, resulting in arbitrary command...

8.6CVSS0.00348EPSS
SaveExploits0References1
CVE
CVE
•added 2026/09/23 7:20 a.m.•12 views

CVE-2026-50228

An unauthenticated local attacker can exploit a vulnerability in Acer NitroSense software (versions up to and including 5.2.63 ) by connecting to an exposed Electron DevTools endpoint on localhost TCP port 9993 . The root cause is that Chromium remote debugging remains enabled in the production a...

8.6CVSS6.4AI score0.00134EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/09/23 7:20 a.m.•7 views

EUVD-2026-85152

An unauthenticated local attacker can connect to the Electron DevTools endpoint exposed by Acer NitroSense software versions up to and including 5.2.63 on localhost TCP port 9993. Because Chromium remote debugging is enabled in the production application, the attacker can execute JavaScript in th...

8.6CVSS6.4AI score0.00134EPSS
SaveExploits0References1
CVE
CVE
•added 2026/09/23 7:15 a.m.•15 views

CVE-2026-50227

An unauthenticated local attacker can connect to the MQTT broker over its localhost WebSocket endpoint in Acer NitroSense software (versions up to and including 5.2.62 ). This vulnerability allows the attacker to invoke exposed ddsc RPC functions , specifically child_process.execSync() , which ca...

8.6CVSS5.9AI score0.00348EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/09/23 7:15 a.m.•8 views

EUVD-2026-85151

An unauthenticated local attacker can connect to the MQTT broker over its localhost WebSocket endpoint in Acer NitroSense software versions up to and including 5.2.62. This allows the attacker to invoke exposed ddsc RPC functions, including childprocess.execSync, resulting in arbitrary command...

8.6CVSS5.9AI score0.00348EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/23 12:00 a.m.•3 views

CVE-2026-50227: Missing Authentication for Critical Function

An unauthenticated local attacker can connect to the MQTT broker over its localhost WebSocket endpoint in Acer NitroSense software versions up to and including 5.2.62. This allows the attacker to invoke exposed ddsc RPC functions, including childprocess.execSync, resulting in arbitrary command...

8.6CVSS5.9AI score0.00348EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/23 12:00 a.m.•3 views

CVE-2026-50228: Active Debug Code

An unauthenticated local attacker can connect to the Electron DevTools endpoint exposed by Acer NitroSense software versions up to and including 5.2.63 on localhost TCP port 9993. Because Chromium remote debugging is enabled in the production application, the attacker can execute JavaScript in th...

8.6CVSS6.4AI score0.00134EPSS
SaveExploits0References2
Kitploit
Kitploit
•added 2026/09/22 3:26 p.m.•10 views

CVE-2026-8069

Acerの名前付きパイプからNT AUTHORITY\SYSTEMへ: CVE-2026-8069 Acer NitroSenseおよびPredatorSense 3.xは、PSSvcというWindowsサービスをインストールし、ローカルユーザーにカスタム名前付きパイププロトコルを公開していました。あるプロトコルコマンドは、呼び出し元が制御する実行可能ファイルのパスを受け入れ、winlogon.exeのトークンを複製し、その実行可能ファイルをNT AUTHORITY\SYSTEMとして起動していました。...

8.5CVSS6.1AI score0.00165EPSS
SaveExploits1References4
NVD
NVD
•added 2026/09/17 9:16 a.m.•11 views

CVE-2026-50608

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service...

5.1CVSS0.00207EPSS
SaveExploits0References1
CVE
CVE
•added 2026/09/17 8:26 a.m.•23 views

CVE-2026-50610

CVE-2026-50610 affects the Acer System Monitoring component bundled with NitroSense and PredatorSense software. The root cause is insufficient access controls in a privileged service , allowing an authenticated local user to access the service and perform unauthorized registry modifications , pot...

9.3CVSS5.6AI score0.0013EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/09/17 8:26 a.m.•12 views

EUVD-2026-81402

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications,...

9.3CVSS5.6AI score0.0013EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/09/17 8:21 a.m.•11 views

CVE-2026-50609 Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, thi...

9.3CVSS5.7AI score0.0013EPSS
SaveExploits0References1
NVD
NVD
•added 2026/09/17 8:17 a.m.•11 views

CVE-2026-50606

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key ...

5.1CVSS0.00099EPSS
SaveExploits0References1
NVD
NVD
•added 2026/09/17 8:17 a.m.•9 views

CVE-2026-50607

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access...

6.9CVSS0.00428EPSS
SaveExploits0References1
NVD
NVD
•added 2026/09/17 8:17 a.m.•18 views

CVE-2026-50605

A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. Insufficient access controls within a privileged service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to...

9.3CVSS0.0013EPSS
SaveExploits0References1
CVE
CVE
•added 2026/09/17 8:05 a.m.•16 views

CVE-2026-50607

CVE-2026-50607 affects the Acer System Monitoring component bundled with NitroSense and PredatorSense . A WebSocket service was configured to listen on all network interfaces rather than a restricted one, which may expose the service to unintended network access. The CVSS 4.0 base score is 6.9 (M...

6.9CVSS5.6AI score0.00428EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/09/17 7:59 a.m.•10 views

CVE-2026-50606 Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key ...

5.1CVSS5.7AI score0.00099EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/09/17 7:59 a.m.•31 views

CVE-2026-50606 Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software